• Title/Summary/Keyword: 이중에너지

Search Result 996, Processing Time 0.024 seconds

A STUDY ON THE BONE MINERAL DENSITY OF ILIAC AND TIBIAL BONE USING DUAL ENERGY X-RAY ABSORPTIOMETRY (이중에너지 방사선 흡수계측법을 이용한 성인 남녀의 장골 및 경골의 골밀도에 관한 연구)

  • Cho, Yong-Seok;Kim, Kyoung-Won;Lee, Keong-Ho;Park, Hyun-Jin;Seo, Sang-Su;Oh, Sang-Youp
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.265-273
    • /
    • 2000
  • Purpose : The aim of this study was to evaluate the bone mineral density of iliac and tibial bone which are frequently selected as autogenic bone graft donor sites, and to evaluate the efficiency of this method as a guideline for the selection of bone graft donor site. Materials and Methods : In this study 61 male and 70 female volunteers at Chungbuk National University Hospital were involved between Jan. 1998 to Sept. 1999. We measured bone mineral density of the iliac and the tibial bone using dual energy X-ray absorptiometry. We evaluated the data using the SAS system for Windows and bone mineral density of the lumbar was used for control. Results : Age showed the highest correlation in correlation matrix between physical and bone variables. Height and weight showed lower correlation of linear increment. In man, the change of bone density according to age demonstrated linear decrease irrespective of the lumbar, ilium, and tibia. In woman, the change of bone density according to age showed cubic form, which increased in the third and forth decade. So it had a peak bone mass on about 35 year-old, thereafter, the change of bone density slowly decreased until 50 year-old, but it rapidly decreased after 50 year-old and it slowly decreased again after 65 year-old. Both in all subjects and subject with osteoporosis, the change of bone mineral density according to age showed statistically significant decrease in lumbar and tibia, but ilium was irrespective. Conclusion : In patients of aged or with osteoporosis, ilium demonstrated less tendency of decrease in bone mineral density than tibia. So this preliminary study suggested that ilium seemed better donor site for autogenic bone graft than tibia.

  • PDF

Transmission Noise Seduction Performance of Smart Panels using Piezoelectric Shunt Damping (압전감쇠를 이용한 압전지능패널의 전달 소음저감 성능)

  • 이중근
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.49-57
    • /
    • 2002
  • The possibility of a transmission noise reduction of piezoelectric smart panels using piezoelectric shunt damping is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing materials are bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonances, piezoelectric damping using the measured electrical impedance model is adopted. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a tube with square crosses section and a loud-speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. Noise reduction performance of a smart panels possessing absorbing material and/or air gap shows a good result at mid frequency region but little effect in the resonance frequency. By enabling the piezoelectric shunt damping, noise reduction of 10dB, 8dB is achieved at the resonance frequencise as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

  • PDF

Development of BMD Phantom using 3D Printing (3D 프린팅을 이용한 골밀도 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.185-192
    • /
    • 2019
  • DXA is the most commonly used BMD examination equipment with the best performance on reflecting the biological alteration with tiny change of bone density. In spite of the importance of the quality control to maintain the accuracy and precision of the examination, considerable number of hospitals are not conducting QC due to the difficulty and high cost of the phantom product. This study develops the cross revision phantom with 3D printer and the change of the degree of infilling filaments which can be readily secured, and provides the usefulness assessment of the developed phantom by comparing with existing products. The Hounsfield Units of ABS, TPU, PLA, 30% Cu-PLA, and 30% Al-PLA are assessed. The Hounsfield Units result at infilling rate 100% was $-149.74{\pm}2.36$, $-55.62{\pm}7.14$, $-7.68{\pm}3.82$, $87.53{\pm}1.07$, and $1795.20{\pm}16.15$. The L1, L2, L3 BMD of 3D printing phantom with linear regression model were $0.620{\pm}0.010g/cm^2$, $1.092{\pm}0.025g/cm^2$, $1.554{\pm}0.026g/cm^2$ which are statistically relevant to the existing phantom products. This result provides the base line data for various medical phantom produce and capability of proper quality control of DXA equipment.

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

Effect of Low-intensity Resistance Training with Blood Flow Restriction on Muscle Volume and Strength in Elderly Women (저강도의 저항성 운동 시 혈류제한 적용이 노인여성의 근 비대와 근력 향상에 미치는 영향)

  • Yeo, Hyo-Seong;Kim, Hyo-Jeong
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.1
    • /
    • pp.535-544
    • /
    • 2015
  • This study was performed to determine the effect of low-intensity resistance training with blood flow restriction (BFR) on muscle volume and strength in elderly women. Sixteen elderly women (70.9±4.6 years) were divided into low (30% 1RM) and high (75% 1RM) intense resistance training groups. Tourniquet cuff (Zimmer, Germany) for BFR was applied only to the right leg during the training period. All subjects performed unilateral leg press, leg extension and leg curl (3 sets×12 repetitions) for 10 weeks (2d/wk). Blood pressure was increased from 110 to 240 mmHg during the training period at the most proximal region of exercised leg. Muscle volume and cross-sectional area (CSA) were measured by MRI and body composition was monitored by dual-energy X-ray absorptiometry (DEXA) and isokinetic muscular strength were analyzed in both legs. The quadriceps CSA (15.2%, p<.001) and muscle volume (13.8%, p<.001) were increased in high-intense trained leg with BFR and the increased rate was highest among groups. The quadriceps CSA (9.8%, p<.001) and muscle volume (6.9%, p<.001) were increased in low-intensity training group with BFR and their increased rates were higher than control groups. The strength by exercise training was significantly improved in all groups and tended to be higher in BFR groups. These results demonstrate low-intensity resistance training with blood flow restriction could be an effective way to improve muscle volume and strength in elderly women.

Correlations of Lumbar and Femoral Bone Mineral Densities with Calcaneal Speed of Sound in Osteoporotic Woman (골다공증 여성에서 요추골 밑 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계)

  • Lee, Kang-Il;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.542-547
    • /
    • 2009
  • In this in vivo study, correlations of lumbar and femoral bone mineral densities (BMDs) with calcaneal speed of sound (SOS) were investigated in 36 osteoporotic women. Areal BMDs of the L2-L4 lumbar spine and the right femoral neck were measured by using dual energy X-ray absorptiometry (DEXA). SOS of the right calcaneus was measured by using ultrasound bone densitometry. Pearson's correlation coefficient (r) and level of significance (p) were used to evaluate the correlations between measurements. Lumbar BMD was highly correlated with femoral BMD (r=0.81). Lumbar and femoral BMDs exhibited similar comparable negative correlations with age (r=-0.52 and r=-0.55). A moderate negative correlation was found between calcaneal SOS and age (r=-0.45). Calcaneal SOS was significantly correlated with lumbar and femoral BMDs, with a higher correlation with femoral BMD rather than with lumbar BMD (r=0.54 and r=0.62). However, calcaneal SOS may not be an optimum index for the estimation of BMD of the most important fracture sites, such as the lumbar and the femur, because it showed lower correlations with lumbar and femoral BMDs compared to that with calcaneal BMD. Therefore, the development of a quantitative ultrasound technology for the direct measurement of acoustic properties at the lumbar and the femur is required to estimate BMD of these sites more accurately.

Production of doubled haploid population derived from the microspore culture of rapeseed (Brassica napus L.) F1 generation and analysis of fatty acid composition (유채 잡종 1세대의 소포자 배양에 의한 배가반수체 집단 선발 및 지방산 조성 분석)

  • Lee, Ji Eun;Park, Ju Hyun;Kim, Kwang Soo;An, Da Hee;Cha, Young Lok
    • Journal of Plant Biotechnology
    • /
    • v.49 no.1
    • /
    • pp.74-81
    • /
    • 2022
  • Brassica napus, an oil crop that produces rapeseed oil, is an allotetraploid (AACC, 2n = 38) produced by natural hybridization between B. rapa and B. oleracea. In this study, microspore was cultured using the F1 developed from a cross between 'EMS26' line with high oleic acid content and 'J8634-B-30' lines. The flower bud size showing the nuclear development at the late uninucleate and binucleate stage with high embryogenesis rate was 2.6 ~ 3.5 mm. Microspores were cultured using only this size and after then most microspore embryo developed into secondary embryos and then regeneration plants obtained from the developed multilobe. The analysis of the ploidy of the plants revealed that 66.7% and 27.8% of the total lines were tetraploids and octoploids, respectively. The sizes of stomatal cells in tetraploids, octoploids, and diploids were 25.5, 35.6, and 19.9 ㎛, respectively, indicating that ploidy level was positively correlated with cell size. Furthermore, 62 tetraploid doubled haploid (DH) lines were selected. The average oleic acid (C18:1) and linolenic acid (C18:3) concentrations of DH were 72.3% and 6.2%, respectively. Oleic acid and linolenic acid concentrations exceeded the two parental values in 5 and 14 DH lines, respectively, suggesting that these two fatty acids had transgressive segregation. Therefore, the DH population can be utilized for the biosynthesis of unsaturated fatty acids in rapeseed and related genes. It can also be used as a breeding material for varieties with high oleic acid concentrations.

Polarization of Stimulated Emission from Optically Pumped AIGaN/GaInN DH (AIGaN/GaInN DH의 광여기 유도방출광의 편광)

  • ;;H. Amano;I. Akasaki
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1994.11a
    • /
    • pp.98-98
    • /
    • 1994
  • 최근 청색반도체레이저의 실현을 위하여 ZnSe가 대표하는 II-Ⅵ족 화합물반도체와 Gan가 대표하는 III족 질화물반도체분야에서 집중적인 연구가 이루어지고 있으며, 아직까지 실용화 되지 않고 있는 청색반도체레이저의 출현에 대하여 많은관심이 모아지고 있다. III족 질화물반도체는 InM(Eg:1.9eV)부터 AIN(Eg: 6.2eV)에 이르기까지 전 조성영역에서 완전한 고용체를 이루며, 실온에서 직접천이형 에너지 대구조를 가지므로 청색 혹은 자외영역에서 동작하는 발광소자를 제작하는데 있어 유망시 되고 있는 소재이다. 특히 GaN와 InN의 3원흔정인 GaInN를 활성층으로 이용하면 그 발전파장을 370nm부터 650nm까지 즉 가시 전 영역으로부터 근 자외영역을 포함할 수 있게 된다. 이 연구에서는 AIGaN/GaInN 이중이종접합(DH) 구조의 고아여기에 의한 유도방출고아의 편광 특성을 조사하였다. 유기금속기상에피텍셜(MOVPE)법으로 성장한 AIGaN/GaInN DH 구조의 표면에 수직으로 펄스 발진 질소레이저(파장: 337.1cm, 주기 10Hz, 폭: 8nsec) 빔을 조사하고 DH구조의 단면으로부터의 유도방출광을 편광기를 통과 시킨 후 스펙트럼을 측정하였다. 입사고아 밀도가 증가함에 따라 약 402nm의 파장에서 유도발출에 의한 가도가 큰 피크가 나타났고, 그 반치폭은 약 18meV이었다. 실온에서 AIGaN/GaInN DH 구조로 부터의 유도방출에 필요한 입사광밀도의 임계치는 약 130㎾/$\textrm{cm}^2$이었다. 한편 편광각이 90$^{\circ}$일때는 발광스펙트럼의 강도가 매우 낮고 단지 자연방출에 의한 스펙트럼만이 나타났다. 편광각이 0$^{\circ}$일 때 최대의 방출광 강도를 나타내었으며, 편광각이 -90$^{\circ}$로 회전함에 따라 발고아강도의 강도가 감소하였다. 이와 같은 결과는 광여기에 의하여 AIGaN/GaInN DH 로 부터의 유도방출광이 GaInN활성층의 단면에 평행한 전기장의방향으로, 즉 TE모드로 선형적으로 편광됨을 의미한다. AIGaN/GanN DH 로 부터의 유도방출이 선형적으로 TE모드로 편광되는 것은 이 구조를 이용한 청색 및 자외선 반도체 레이저다이오드의 실현에 매우 유익한 것이다.

  • PDF

Analysis regarding the Environmental Impact of the Life Cycle of Housing Complexes in Korea (국내 주거 단지에 대한 전과정 환경영향 분석)

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.5
    • /
    • pp.13-21
    • /
    • 2014
  • This study on condominium complex will adopt the quantitative assessment of the influence on the environment throughout the entire life cycle of buildings. This paper applies input-out analysis in order to analyse embodied energy regarding input of materials at material production phase. Also, it calculates environment load at use and demolition and destruction Phases of buildings as analysing energy consumption. The study categorises environment load as six impact categories and undertakes environmental impact evaluation. The consequence shows that the environment load of multi-unit dwelling takes up 88.2% out of the entire environment load of condominium complex. Also, as a result of analyzing the environmental impact of the life cycle of condominium buildings, it was found that such environmental impact comprised of about 11.96% of all industries in Korea that had an environmental impact.

The Correlation Analysis and Correction factor of BMD in Forearm and Lumbar with DXA (DXA를 이용한 전완부와 요추부 골밀도 검사의 보정계수 및 상관관계 연구)

  • Han, Man-Seok
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.551-556
    • /
    • 2013
  • The Forearm and the lumbar spine bone mineral density bone mineral density values obtained through, T-score and Z-score correlation between numerical and calibration function obtained as a result of any one part to another part of the results is intended to infer. Groups of 66 patients, 11 patients by age 20-70 were composed of patients measured with the forearm and lumbar spine bone mineral density T-score and Z-score of the survey for each of the three factors that correlated to assess the correlation Find the correction factor to obtain the relationship. Bone mineral density of the correlation coefficient R = 0.769 correction factor is Y = 1.541X + 0.133. T-score of correlation coefficient R = 0.768 and the correction factor Y = 0.715X - 0.4 is Z-score of the correlation coefficient R = 0.635 correction factor Y = 0.751X - 0.162. It is regarded that there will be a clinical availability which can analogize the result of a part by using the result of the other part.