DOI QR코드

DOI QR Code

Analysis regarding the Environmental Impact of the Life Cycle of Housing Complexes in Korea

국내 주거 단지에 대한 전과정 환경영향 분석

  • Choi, Doo-Sung (Department of Building Equipment & Fire Protection System, Chungwoon University) ;
  • Jeon, Hung-Chan (Department of Architectural Engineering, Suwon University) ;
  • Cho, Kyun-Hyong (Department of Architectural Engineering, Suwon University)
  • 최두성 (청운대학교 건축소방설비학과) ;
  • 전흥찬 (수원대학교 건축공학과) ;
  • 조균형 (수원대학교 건축공학과)
  • Received : 2014.03.12
  • Accepted : 2014.07.28
  • Published : 2014.09.30

Abstract

This study on condominium complex will adopt the quantitative assessment of the influence on the environment throughout the entire life cycle of buildings. This paper applies input-out analysis in order to analyse embodied energy regarding input of materials at material production phase. Also, it calculates environment load at use and demolition and destruction Phases of buildings as analysing energy consumption. The study categorises environment load as six impact categories and undertakes environmental impact evaluation. The consequence shows that the environment load of multi-unit dwelling takes up 88.2% out of the entire environment load of condominium complex. Also, as a result of analyzing the environmental impact of the life cycle of condominium buildings, it was found that such environmental impact comprised of about 11.96% of all industries in Korea that had an environmental impact.

본 연구는 건축물 중 공동주택 단지를 대상으로, 건축물에 투입되는 자재생산부터 건축물이 해체되는 전과정동안 환경에 미치는 영향을 6개의 환경영향 범주로 구분하여 정량적으로 산출하였으며, 국내의 모든 산업이 환경에 미치는 영향을 대략적으로 분석하여 비교 평가하였다. 총 27 단지에 대한 환경영향을 분석한 결과 단지를 구성하는 건물 및 시설별로는 공동주택 건물이 단지 전체 대비 약 88.2%를 차지하는 것으로 분석되었으며, 이후 지하주차장, 공통부분, 복지시설, 판매시설, 기타시설 순으로 환경에 미치는 영향이 큰 것으로 분석되었다. 이중 가장 영향이 큰 공동주택 건물만을 대상으로 분석한 경우에는 전과정 중 사용단계에서 환경에 미치는 영향이 가장 크게 나타났으며 이후 자재생산단계, 시공단계, 해체 및 폐기단계 순으로 환경에 미치는 영향이 크게 분석되었다. 또한 공동주택 건물의 전과정에 대한 환경영향 분석 결과 국내 총 산업 대비 약 11. 96%를 차지하는 것으로 분석되었다.

Keywords

References

  1. Kim, J., Kim, S. and Sohn, J. (2004). "A Study on the Estimation of the Environmetal Load Intensity of Construction Materials for the Building LCA." Paper for Architectural institute of Korea, 20(7), pp. 211-218.
  2. Lee, K., Lee, H. and Yang, J. (2010). "A Study on the Functional Unit Trend of Carbon Dioxide Emission in the Construction Materials between 2000, 2003 and 2005." Paper of Architectural Institute of Korea Ecological Environment, 10(5), pp. 123-129.
  3. Korea LCI Database Information Network, (Feb. 12, 2014)
  4. Woo, J. and Shin, S. (2010). "The Environmental Load Comparison Evaluation of The Apartment House for Main Construction Materials of Standard Apartment House." Paper of Architectural Institute of Korea Ecological Environment, 10(1), pp. 85-90.
  5. Choi, D., Chun H., Cho, K., Kim Y. and Jun, Y. (2013). "Development of a Carbon Emission Evaluation Index for Apartment Buildings." Workshop on Architecture and Civil Engineering, SERSC 32, pp. 31-34.
  6. LEE, S. and Chun, Y. (2004). "A stydy of LCA(Life Cycle Assessment) to a office building remodeling -Focused on Electrical Equipment-" Journal of the Korean Solar Energy Society, 24(3), pp. 85-92.
  7. Lee, G., Kwon, Y. and Rhee, E. (2002). "A Study on the Development of the Evaluation Model and Computerizing Program of Apartment Building Considering Environmental Load and Costs." Paper for Architectural institute of Korea, 18(6), pp. 159-166.
  8. Jeong, Y., Choi, G., Kang, J. and Lee, S. (2008). "Development of Life Cycle Assessment Program(K-LCA) for Estimating Environmental Load of Buildings." Paper for Architectural institute of Korea, 24(5), pp. 259-266.
  9. Keum, W., Shin, S., Roh, S. and Tae, S. (2012). "TheDevelopment of Life Cycle CO2 Assessment System Based on Eco-friendly Building Alternative Assessment." Paper for Architectural institute of Korea, 28(5), pp. 87-94.
  10. ISO (2006). "ISO14040 Environmental management - Life Cycle Assessment - principles and frame."
  11. The Bank of Korea (2009). "2008 Input-Output Tables."
  12. EIA (2002). "International Energy Annual(EIA) 2000"
  13. Korea National Oil Corporation, (Jun. 5, 2013)
  14. Henrik, W., Michael, H. and Leo, A. (1997). "Environmental Assessment of Products, Denmark, KLUWER ACADEMIC PUBLISHERS."
  15. Lee, K., Noh, J. and Park, P. (1999). "Determination of weighting factor and its application to the LCA of a Printed Printed Circuit Board." paper for Korean Society for Life Cycle Assessment, pp. 39-44.
  16. IPCC (2006). "Global Warming Potential"
  17. Rechard, G. D., Michael, E. J., Sandra, M. S. and Michael, J. P. (1998). "Photochemical ozone creation potentials for organic compounds in Northwest Europe calculated with a master Chemical mechanism." Atmospheric Environment, 32(14-15), pp. 2429-2441. https://doi.org/10.1016/S1352-2310(98)00053-3
  18. Statistics Korea, (Jun. 5, 2013)
  19. Kim, C., Shin, D., Han, J. and Hwang, Y. (2014). "Comparison Analysis of Environmental Performance between Reconstruction and Remodeling Alternatives for Aged - Focused on CO2 Emissions Analysis -" Korean Journal of Construction Engineering and Management, KICEM, 15(1), pp. 87-100. https://doi.org/10.6106/KJCEM.2014.15.1.087