• Title/Summary/Keyword: 이용통계표준

Search Result 634, Processing Time 0.03 seconds

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Different Uptake of Tc-99m ECD and Tc-99m HMPAO in the Normal Brains: Analysis by Statistical Parametric Mapping (정상 뇌 혈류 영상에서 방사성의약품에 따라 혈류 분포에 차이가 있는가: 통계적 파라미터 지도를 사용한 분석)

  • Kim, Euy-Neyng;Jung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.244-254
    • /
    • 2002
  • Purpose: This study investigated the differences between technetium-99m ethyl cysteinate dimer (Tc-99m ECD) and technetium-99m hexamethylpropylene amine oxime (Tc-99m HMPAO) uptake in the normal brain by means of statistical parametric mapping (SPM) analysis. Materials and Methods: We retrospectively analyzed age and sex matched 53 cases of normal brain SPECT. Thirty-two cases were obtained with Tc-99m ECD and 21 cases with Tc-99m HMPAO. There were no abnormal findings on brain MRIs. All of the SPECT images were spatially transformed to standard space, smoothed and globally normalized. The differences between the Tc-99m ECD and Tc-99m HMPAO SPECT images were statistically analyzed using statistical parametric mapping (SPM'99) software. The differences bgetween the two groups were considered significant ant a threshold of corrected P values less than 0.05. Results: SPM analysis revealed significantly different uptakes of Tc-99m ECD and Tc-99m HMPAO in the normal brains. On the Tc-99m ECD SPECT images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the basal ganglia and thalamus, and in the superior region of the cerebellum. On the Tc-99m HMPAO SPECT images, relatively higher uptakes was observed in subcortical areas of the frontal region, temporal lobe, and posterior portion of inferior cerebellum. Conclusion: Uptake of Tc-99m ECD and Tc-99m HMPO in the normallooking brain was significantly different on SPM analysis. The selective use of Tc-99m ECD of Tc-99m HMPAO in brain SPECT imaging appears especially valuable for the interpretation of cerebral perfusion. Further investigation is necessary to determine which tracer is more accurate for diagnosing different clinical conditions.

Detection of Copy Number Variation of the KIT Gene in the Landrace Breed using an Quantitative Oligonucleotide Ligation Assay(qOLA) (Quantitative Oligonucleotide Ligation Assay(qOLA)를 이용한 Landrace 품종의 KIT 유전자 반복수 변이 탐지)

  • Seo, B.Y.;Kim, J.H.;Nahm, D.W.;Yoo, C.K.;Lee, S.H.;Lee, J.B.;Lim, H.T.;Jung, E.J.;Cho, I.C.;Heo, K.N.;Jeon, J.T.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.559-568
    • /
    • 2007
  • Recently, copy number variations (CNV) of genes or genomic segments have been intensively studied and various analysis methods have been developed. In this study, quantitative oligonucleotide ligation assay (qOLA) was applied to investigate CNV of KIT gene in the Landrace breed. A combined assay using qOLA and pyrosequencing, 6 genotype classes, I1/I1 or I3/i (IBe), I1/I2 or I3/IP, I1/I3, I1/IP or I2/i (IBe), I2/I2and I2/IP, were identified from 44 Landrace pigs. Genotype assignment using grouping features of measurements on a scatter plot showed 100% agreement with those using a statistical assignment by PROC FASTCLUS procedure implemented in the SAS package. Two versions (3100 and 3130) of ABI sequencers gave the same genotyping results, indicating there was no influence on qOLA by different versions of instrument, however, the means of standard deviation and coefficient of variation from the qOLA on a ABI 3130 (2.33 and 4.10) was lower than those from the qOLA on a ABI 3100 (2.67 and 4.81). Effect of proteinase K treatment on the PCR product followed by qOLA was very clear because noise peaks were disappeared and the observed ration fit better to the reference ratio corresponding to each genotype.

Diameters of the Thoracic Aorta Measured with Multidetector Computed Tomography (다중검출 전산화 단층촬영을 이용하여 측정한 흉부대동맥의 직경)

  • Lee, Gun;Lim, Chang-Young;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • Background: Background: Computed tomography (CT) is the main tool for detecting abnormalities of the thoracic aorta, but conventional CT only shows the cross-sectional images. These CT images have some limitations fo accuratly measuring the thoracic aortic diameters at various levels. Multidetector computed tomography (MDCT) overcomes these limitations. We measured the thoracic aortic diameter perpendicular to the loop-shaped thoracic aortic course and this was studied in relation to age, gender, height, weight, the body surface area, the body mass index and the presence of hypertension. Material and Method: Thirty hundred thirty one patients (males: 141 patients and females: 190 patients) who had no abnormalities of the thoracic aorta were investigated using MDCT aortography. They were divided into three age categories: 20~39 years old, 40~59 years old and over age 60. The image was reformed with multiplanar reconstruction and the diameter of the aorta was measured perpendicular to the aortic course at 5 anatomic segments. Level A was the mid-ascending aorta, level B was the distal ascending aorta, level C was the aortic arch, level D was the aortic isthmus and level E was the mid-descending aorta. Result: The mean age was 49.5 years old for males and 54.9 years old for females (p<0.05). The mean diameter of the thoracic aorta at level A was 31.1 mm, that at level B was 30.2 mm, that at level C was 26.5 mm, that at level D was 24.0 mm and that at level E was 22.6 mm. The diameters at all the levels were gradually increased with age. Hypertensive patients had larger diameters than did the non-hypertensive population. There was a positive correlation between the ascending aortic diameter (levels A&B) and height and the body surface area, but there were no statistical differences at the aortic arch (level C) and the descending aorta (levels D&E). There were no statistical differences of the weight and body mass index at all levels. Conclusion: The diameters of the thoracic aortas were directly correlated with gender, age and hypertension. Height and the body surface area were only correlated with the ascending aorta. Weight and the body mass index have no statistical difference at all levels. We measured the age related thoracic aortic diameters and the upper normal limits and we provide this data as reference values for the thoracic aortic diameter in the Korean population.

Normative data of penile length in Korean newborns (한국인 신생아 음경 길이에 대한 연구)

  • Kim, Sang Yeob;Jun, Jae Sung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.944-949
    • /
    • 2008
  • Purpose : As modern society has became more open, interest in healthy internal and external growth has increased, including that pertaining to penile length in children. A micropenis is defined as one where penile length is more than 2 SD (standard deviation) below the mean, and it can be traced back to chromosome and endocrine disorders. The authors executed this study to suggest guidelines for the study of the micropenis and standard information for penile length in Korean newborns. Methods : The subjects of this study were 168 male infants between 37 and 42 weeks of gestational age, none of whom had any complications during pregnancy or birth; each had been born in Daegu Fatima Hospital between February and June 2007. Penile length was measured using conventional stretched penile length measurement (CPLM) and syringe methods. Results : Penile length was $3.02{\pm}0.25cm$ (F=36.467, $R^2=0.180$, P<0.001) when measured with CPLM, and $3.29{\pm}0.26cm$ (F=9.149, $R^2=0.052$, P<0.001) with the syringe method. There was no statistically significant difference in the penile length of newborn infants as a result of taking measurements with the two methods, and both methods showed significance at 0.631 in terms of Pearson's correlation coefficient, at the level of P=0.01. Conclusion : In this study, penile length tended to be longer when gestational age was longer, and a micropenis can be assumed to be one less than 2.5 cm using CPLM and less than 2.8 cm using the syringe method. In the case of a concealed penis, the syringe method is helpful. When a micropenis is assumed, close observation by outpatient department personnel, and additional endocrine and chromosome studies should be undertaken after sufficiently consulting the parents.

A Survey on the Perception and Usage Status of Dietitians in Food Service Business for Meat Products (단체급식소 영양사의 육가공품에 대한 인식 및 이용실태 조사)

  • Yong, Eun-Zu;Choi, Youn-Sang;Lee, Keun-Taik
    • Food Science of Animal Resources
    • /
    • v.29 no.1
    • /
    • pp.121-131
    • /
    • 2009
  • This study attempted to investigate the perception and usage status for meat products of dietitians in the food service business in Seoul and Gangwon province. 32.8% of dietitians decided the menu reflecting the taste of students. Most of the dietitians (89.2%) checked the manufacture date of the processed meat products when they were supplied. To address the question as to whether they could distinguish the difference among ham, pressed ham, and sausage, most of them answered; 'can distinguish a little' (47.5%) or 'can't distinguish' (36.7%). The most frequently provided processed meat products were ham (33.9%), followed by sausage (21.7%). However, it is assumed that the dietitians might have mistaken the pressed ham for the classic ham. The most common frequency of the serving processed meat product in the food services was once a month (41.6%). Most desired aspect of quality improvement for the processed meat products was answered as 'hygiene/safety' (31.5%), and followed by 'higher quality' (26%). In conclusion, the improvement of the product quality and the strengthening of public information would be prerequisites for expanding the use of processed meat products in the food services and business-to-business (B2B) market in the future.

The Discriminating Nature of Dopamine Transporter Image in Parkinsonism: The Competency of Dopaminergic Transporter Imaging in Differential Diagnosis of Parkinsonism: $^{123}I-FP-CIT$ SPECT Study (도파민운반체 영상의 파킨슨증 감별진단 성능: $^{123}I-FP-CIT$ SPECT 연구)

  • Kim, Bom-Sahn;Jang, Sung-June;Eo, Jae-Seon;Park, Eun-Kyung;Kim, Yu-Kyeong;Kim, Jong-Min;Lee, Won-Woo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.272-279
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the discriminating nature of $^{123}I-FP-CIT$ SPECT in patients with parkinsonism. Methods: $^{123}I-FP-CIT$ SPECT images acquired from the 18 normal controls; NC ($60.4{\pm}10.0$ yr) and 237 patients with parkinsonism ($65.9{\pm}9.2$ yr) were analyzed. From spatialIy normalized images, regional counts of the caudate, putamen, and occipital lobe were obtained using region of interest method. Binding potential (BP) was calculated with the ratio of specific to nonspecific binding activity at equilibrium. Additionally, the BP ratio of putamen to caudate (PCR) and asymmetric Index (ASI) were measured. Results: BPs of NC $3.37{\pm}0.57,\; 3.10{\pm}0.41,\; 3.23{\pm}0.48$ for caudate, putamen, whole striatum, respectively) had no significant difference with those of essential tremor; ET ($3.31{\pm}0.64,\; 3.06{\pm}0.61,\; 3.14{\pm}0.63$) and Alzheimer's disease; AD (3.33 $\pm$0.60, 3.29$\pm$0.79, 3.31$\pm$0.70), but were higher than those of Parkinson's disease; PD (1.92$\pm$0.74, 1.39$\pm$0.68, 1.64$\pm$0.68), multiple system atrophy; MSA (2.36$\pm$1.07, 2.16$\pm$0.91, 2.26$\pm$0.96), and dementia with Lewy body; DLB (1.95$\pm$0.72, 1.64$\pm$0.65, 1.79$\pm$0.66)(p<0.005). PD had statisticalIy lower values of PER and higher values of ASI than those of NC (p<0.005). And PD had significantIy lower value of PCR, higher ASI and lower BP in the putamen and whole striatum than MSA (p<0.05). Conclusion: Dopamine transporter image of $^{123}I-FP-CIT$ SPECT was a good value in differential diagnosis of parkinsonism.

Calibration of Gauge Rainfall Considering Wind Effect (바람의 영향을 고려한 지상강우의 보정방법 연구)

  • Shin, Hyunseok;Noh, Huiseong;Kim, Yonsoo;Ly, Sidoeun;Kim, Duckhwan;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.19-32
    • /
    • 2014
  • The purpose of this paper is to obtain reliable rainfall data for runoff simulation and other hydrological analysis by the calibration of gauge rainfall. The calibrated gauge rainfall could be close to the actual value with rainfall on the ground. In order to analyze the wind effect of ground rain gauge, we selected the rain gauge sites with and without a windshield and standard rain gauge data from Chupungryeong weather station installed by standard of WMO. Simple linear regression model and artificial neural networks were used for the calibration of rainfalls, and we verified the reliability of the calibrated rainfalls through the runoff analysis using $Vflo^{TM}$. Rainfall calibrated by linear regression is higher amount of rainfall in 5%~18% than actual rainfall, and the wind remarkably affects the rainfall amount in the range of wind speed of 1.6~3.3m/s. It is hard to apply the linear regression model over 5.5m/s wind speed, because there is an insufficient wind speed data over 5.5m/s and there are also some outliers. On the other hand, rainfall calibrated by neural networks is estimated lower rainfall amount in 10~20% than actual rainfall. The results of the statistical evaluations are that neural networks model is more suitable for relatively big standard deviation and average rainfall. However, the linear regression model shows more suitable for extreme values. For getting more reliable rainfall data, we may need to select the suitable model for rainfall calibration. We expect the reliable hydrologic analysis could be performed by applying the calibration method suggested in this research.

MMP-2, MMP-8 Expression in gingival tissue of Chronic Periodontitis associated to Type 2 Diabetes Mellitus (2형 당뇨병을 동반한 만성 치주염 환자의 치은조직에서 MMP-2, MMP-8의 발현 양상 비교)

  • Kang, Min-Gu;Cha, Hyun-Jeong;Song, Sun-Hee;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.661-674
    • /
    • 2005
  • The purpose of this study was to quantify and compare the level of MMP-2, MMP-8 in the healthy, inflammed gingival tissue and inflammed gingival tissue associated with type 2 DM. We investigate whether expression of MMP-2, MMP-8 is increased by chronic periodontitis associated with type 2 DM. Gingival tissue samples were obtained during periodontal surgery or tooth extraction. Based on patient's systemic condition & clinical criteria of gingiva, each gingival samples were divided into three groups. Group l(n=8) is clinically healthy gingiva without bleeding and no evidence of bone resorption or periodontal pockets, obtained from 8 systemically healthy patients. Group 2(n=8) is inflammed gingiva from patients with chronic periodontitis. Group 3(n=8) is inflammed gingiva from type 2 diabetic patients with chronic periodontitis. Tissue samples were prepared and analyzed by Western blotting. The quantification of MMP-2, MMP-8 was performed using a densitometer and statistically analyzed by ANOVA. MMP-2, MMP-8 was expressed in all samples including healthy gingiva and increased in group 3 compared to group 1 and 2, and showed that significant variation was observed between group 1 & 3 in MMP-8 results. In conclusion, this study demonstrated that human gingival tissue with chronic periodontitis associated to type 2 diabetes showed slightly elevated MMP-2, MMP-8 levels compared to healthy gingiva and non-diabetic inflamed gingiva.

A study on the rainfall management target considering inter-event time definition (IETD) (무강우 지속시간(IETD)을 고려한 빗물관리 목표량 설정 방안 연구)

  • Baek, Jongseok;Kim, Jaemoon;Park, Jaerock;Lim, Kyoungmo;Shin, Hyunsuk
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.603-611
    • /
    • 2022
  • In urban areas, the impermeable area continues to increase due to urbanization, which interferes with the surface penetrating and infiltrating of rainwater, causing most rainwater runoff to the surface, deepening the distortion of water circulation. Distortion of water circulation affects not only flood disasters caused by rainfall and runoff, but also various aspects such as dry stream phenomenon, deterioration of water quality, and destruction of ecosystem balance, and the Ministry of Environment strongly recommends the use of Low Impact development (LID) techniques. In order to apply the LID technique, it is necessary to set a rainwater management target to handle the increase in outflow after the development of the target site, and the current standard sets the rainwater management target using the 10-year daily rainfall. In this study, the difference from the current standards was analyzed through statistical analysis and classification of independent rainfall ideas using inter-event time definition (IETD) in setting the target amount of rainwater management to improve water circulation. Using 30-year rainfall data from 1991 to 2020, methods such as autocorrelation coefficient (AC) analysis, variation coefficient (VC) analysis, and annual average number of rainfall event (NRE) analysis were applied, and IETD was selected according to the target rainfall period. The more samples the population had, the more IETD tended to increase. In addition, by analyzing the duration and time distribution of independent rainfall according to the IETD, a plan was proposed to calculate the standard design rainfall according to the rainwater management target amount. Therefore, it is expected that it will be possible to set an improved rainwater management target amount if sufficient samples of independent rainfall ideas are used through the selection of IETD as in this study.