• Title/Summary/Keyword: 이동 시간

Search Result 6,807, Processing Time 0.05 seconds

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Comparison of the pollinating activities according to number of combs per honeybee (Apis mellifera) hive released in the strawberry (Seolhyang var.) vinyl-houses (서양종꿀벌(Apis mellifera L.) 소비매수별 시설딸기(설향) 화분매개활동 비교)

  • Lee, Sang-Beom;Yoon, Hyung-Joo;Kang, Seok Woo;Kwon, Jae Seok;Park, Ki-Kwan
    • Journal of Sericultural and Entomological Science
    • /
    • v.52 no.2
    • /
    • pp.134-141
    • /
    • 2014
  • This study was examined the pollinating activity and the economical effect according to numbers released of Apis mellifera in the $825m^2$ strawberry (Seolhyang var.) vinyl-houses. The time-zone of pollinating activity relative to numbers of honeycomb released at the strawberry (Seolhyang var.) vinyl-houses was together from 9A.M. to 4P.M., and the peak time of pollinating activity was 11A.M.. The effects on pollinating activity relative to the honeycomb numbers in the honeybee hive released at the strawberry houses were ordered 5 honeycombs (11,000 heads), 4 honeycombs (8,800 heads) and 3 honeycombs (6,600 heads). The rate of workers lost in A. mellifera hives with 5 honeybee combs and 4 honeycombs during the strawberry cultivating period were lower than that of 3 honeycombs. The rates of fruit set by pollinating activity relative to the honeycomb numbers in the honeybee hive released at the strawberry vinyl-houses were same level with over 98%. The fruit qualities; No. of seeds, sugar content and rate of normal fruit set were same level, but fruit weights were ordered 5 honeycombs in 37.2 g, 4 honeycombs in 35.6 g and 3 honeycombs in 32.6 g. The marketing incomes of 4 honeycombs and 5 honeycombs were 9% to 13% higher than that of 3 honeycombs, respectively. Therefore, when the strawberry (Seolhyang var.) was planted at $825m^2$ of a vinyl-houses, it was surveyed that the most suitable numbers of honeycomb were over 4 honeycombs (8,800 heads).

지점우량 자료의 분포형 설정과 내용안전년수에 따르는 확률강우량에 관한 고찰 - 국내 3개지점 서울, 부산 및 대구를 중심으로 -

  • Lee, Won-Hwan;Lee, Gil-Chun;Jeong, Yeon-Gyu
    • Water for future
    • /
    • v.5 no.1
    • /
    • pp.27-36
    • /
    • 1972
  • This thesis is the study of the rainfall probability depth in the major areas of Korea, such as Seoul, Pusan and Taegu. The purpose of the paper is to analyze the rainfall in connection with the safe planning of the hydraulic structures and with the project life. The methodology used in this paper is the statistical treatment of the rainfall data in the above three areas. The scheme of the paper is the following. 1. The complementation of the rainfall data We tried to select the maximm values among the values gained by the three methods: Fourier Series Method, Trend Diagram Method and Mean Value Method. By the selection of the maximum values we tried to complement the rainfall data lacking in order to prevent calamities. 2. The statistical treatment of the data The data are ordered by the small numbers, transformed into log, $\sqrt{}, \sqrt[3]{}, \sqrt[4], and$\sqrt[5], and calculated their statistical values through the electronic computer. 3. The examination of the distribution types and the determination of the optimum distibution types By the $x^2-Test$ the distribution types of rainfall data are examined, and rejected some part of the data in order to seek the normal rainfall distribution types. In this way, the optimum distribution types are determined. 4. The computation of rainfall probability depth in the safety project life We tried to study the interrelation between the return period and the safety project life, and to present the rainfall probability depth of the safety project life. In conclusion we set up the optimum distribution types of the rainfall depths, formulated the optimum distributions, and presented the chart of the rainfall probability depth about the factor of safety and the project life.ct life.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Effect of Carrier on Labeling and Biodistribution of Re-188-Hydroxyethylidene diphosphonate (담체가 Re-188-Hydroxyethylidene Diphosphonate의 표지와 생체내분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Bo-Kwang;Cho, Jung-Hyuk;Lee, Dong-Soo;Chung, June-Key;Lee, Seung-Jin;Jin, Ren-Jie;Lee, Sang-Eun;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.344-352
    • /
    • 2000
  • Purpose: Re-188-Hydroxyethylidene diphosphonate (HEDP) is a new cost-effective agent for systemic radioisotope therapy of metastatic bone pain. We investigated the influence of carrier for labeling and biodistribution of Re-188-HEDP using HEDP kit with or without carrier ($KReO_4$). Materials and Methods: The kits (HEDP 15 mg, gentisic acid 4 mg and $SnCl_2.2H_2O_2$ 4.5 mg) with or without carrier ($KReO_4$ 0.1 mg) were labeled with Re-188 solution, made available from an in-house generator by boiling for 15 min. We compared the labeling efficiency and stability of carrier-added and carrier-free preparations of Re-188-HEDP Biodistribution and imaging studies of each preparation were performed in ICR mice ($1.85{\sim}3.7MBq/0.1ml$) and SD rats ($74.1{\sim}85.2MBq/0.5ml$). Results: The carrier-added preparation showed high labeling efficiency (95% at pH 5) and high stability in serum (88%, 3 hr). However, the carrier-free preparation showed low labeling efficiency (59% at pH 5) and low stability (43%, 3 hr). The carrier-added preparation showed high uptake in bone and low uptake in stomach and kidneys. However, the carrier-free preparation showed lower uptake in bone and higher uptake in both stomach and kidneys, which is supposed to be due to released perrhenate. The carrier-added preparation also showed better images with higher skeletal accumulation, lower uptake in other organs and lower soft tissue uptake than the carrier-free preparation. Conclusion: The results of these studies clearly demonstrate that addition of carrier perrhenate is required for high labeling efficiency, stability, bone uptake and good image quality of Re-188-HEDP.

  • PDF

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

Estimation of the Optimum Number of Machines and Equipments for Professional Dairy Farm (낙농 전업농의 기계장치 최적 규모 추정)

  • 유병기;이용범;장진택;이동현;권두중;기광석;성시흥;이대원
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.27-39
    • /
    • 1996
  • A survey was conducted for dairy farmer to estimate the optimum number of machine and equipment in 1994. Labor hours, operation costs and operation methods for each dairy processing were investigated and analyzed for the farmers to find the expected numbers of machine and equipment on the basis of the desired farm scale. And also, the estimated models were compared and analyzed with the conventional models which more than half dairy farmers used bucket milker in tie stall barn. Some of the results are as follows : 1. Analysis results of conventional model showed that a dairy farm could raise to 15 heads of dairy cow with family labor of 1.5 men, labor hours of 2, 700 in you and total operation costs of 734 thousand won per head. 2. The result, used in conjunction with minimum operation costs in tie stall barn, showed that 28 dairy cows could be raised by using concentrates feeding by hoppers, water supply by water cups, milking by pipeline milker, and manure cleaning by barn cleaner with total operation costs of 520 thousands won per head. 3. The total operation costs of a loose barn system is higher than those of tie stall barn system to raise about 30 heads. For the loose barn system, the herringbone parlour was used for milking, concentrate feeding by automatic concentrate feeder, water supply by thermal insulation feeder, and manure cleaning by scraper with total operation costs of 582 thousands won per head every year.

  • PDF

Key Methodologies to Effective Site-specific Accessment in Contaminated Soils : A Review (오염토양의 효과적 현장조사에 대한 주요 방법론의 검토)

  • Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.383-397
    • /
    • 1999
  • For sites to be investigated, the results of such an investigation can be used in determining foals for cleanup, quantifying risks, determining acceptable and unacceptable risk, and developing cleanup plans t hat do not cause unnecessary delays in the redevelopment and reuse of the property. To do this, it is essential that an appropriately detailed study of the site be performed to identify the cause, nature, and extent of contamination and the possible threats to the environment or to any people living or working nearby through the analysis of samples of soil and soil gas, groundwater, surface water, and sediment. The migration pathways of contaminants also are examined during this phase. Key aspects of cost-effective site assessment to help standardize and accelerate the evaluation of contaminated soils at sites are to provide a simple step-by-step methodology for environmental science/engineering professionals to calculate risk-based, site-specific soil levels for contaminants in soil. Its use may significantly reduce the time it takes to complete soil investigations and cleanup actions at some sites, as well as improve the consistency of these actions across the nation. To achieve the effective site assessment, it requires the criteria for choosing the type of standard and setting the magnitude of the standard come from different sources, depending on many factors including the nature of the contamination. A general scheme for site-specific assessment consists of sequential Phase I, II, and III, which is defined by workplan and soil screening levels. Phase I are conducted to identify and confirm a site's recognized environmental conditions resulting from past actions. If a Phase 1 identifies potential hazardous substances, a Phase II is usually conducted to confirm the absence, or presence and extent, of contamination. Phase II involve the collection and analysis of samples. And Phase III is to remediate the contaminated soils determined by Phase I and Phase II. However, important factors in determining whether a assessment standard is site-specific and suitable are (1) the spatial extent of the sampling and the size of the sample area; (2) the number of samples taken: (3) the strategy of taking samples: and (4) the way the data are analyzed. Although selected methods are recommended, application of quantitative methods is directed by users having prior training or experience for the dynamic site investigation process.

  • PDF

Estimation of Surface fCO2 in the Southwest East Sea using Machine Learning Techniques (기계학습법을 이용한 동해 남서부해역의 표층 이산화탄소분압(fCO2) 추정)

  • HAHM, DOSHIK;PARK, SOYEONA;CHOI, SANG-HWA;KANG, DONG-JIN;RHO, TAEKEUN;LEE, TONGSUP
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.3
    • /
    • pp.375-388
    • /
    • 2019
  • Accurate evaluation of sea-to-air $CO_2$ flux and its variability is crucial information to the understanding of global carbon cycle and the prediction of atmospheric $CO_2$ concentration. $fCO_2$ observations are sparse in space and time in the East Sea. In this study, we derived high resolution time series of surface $fCO_2$ values in the southwest East Sea, by feeding sea surface temperature (SST), salinity (SSS), chlorophyll-a (CHL), and mixed layer depth (MLD) values, from either satellite-observations or numerical model outputs, to three machine learning models. The root mean square error of the best performing model, a Random Forest (RF) model, was $7.1{\mu}atm$. Important parameters in predicting $fCO_2$ in the RF model were SST and SSS along with time information; CHL and MLD were much less important than the other parameters. The net $CO_2$ flux in the southwest East Sea, calculated from the $fCO_2$ predicted by the RF model, was $-0.76{\pm}1.15mol\;m^{-2}yr^{-1}$, close to the lower bound of the previous estimates in the range of $-0.66{\sim}-2.47mol\;m^{-2}yr^{-1}$. The time series of $fCO_2$ predicted by the RF model showed a significant variation even in a short time interval of a week. For accurate evaluation of the $CO_2$ flux in the Ulleung Basin, it is necessary to conduct high resolution in situ observations in spring when $fCO_2$ changes rapidly.

The Far-infrared Drying Characteristics of Steamed Sweet Potato (증자 호박고구마의 원적외선 건조특성)

  • Lee, Dong Il;Lee, Jung Hyun;Cho, Byeong Hyo;Lee, Hee Sook;Han, Chung Su
    • Food Engineering Progress
    • /
    • v.21 no.1
    • /
    • pp.42-48
    • /
    • 2017
  • The purpose of this study was to verify the drying characteristics of steamed sweet potato and to establish optimal drying conditions for far-infrared drying of steamed sweet potato. 4 kg of steamed sweet potato was sliced to thicknesses of 8 and 10 mm, and dried by a far-infrared dryer until a final moisture content of $25{\pm}0.5%$. The far-infrared dryer conditions were an air velocity of 0.6, 0.8 m/s and drying temperature of 60, 70, and $80^{\circ}C$. The results can be summarized as follows. The drying time tended to be reduced as temperature and air velocity for drying increased. The Lewis and Modified Wang and Singh models were found to be suitable for drying of steamed sweet potato by a far-infrared dryer. The color difference was 35.09 on the following conditions: Thickness of 8 mm, temperature of $80^{\circ}C$, and air velocity of 0.8 m/s. The highest sugar content ($59.11^{\circ}Brix$) was observed on the conditions of a thickness of 8 mm, temperature of 80, and air velocity of 0.8 m/s. Energy consumption decreased on the conditions of higher temperature, slower air velocity, and thinner steamed sweet potato.