• Title/Summary/Keyword: 이동장치

Search Result 2,686, Processing Time 0.031 seconds

International Trends in Wheelchair Power Assist Add-ons Development (휠체어 동력 보조장치 개발 국제 동향)

  • Suk-Min Lee;Ki-Won Choi;Inhyuk Moon;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.2
    • /
    • pp.143-150
    • /
    • 2023
  • As Korea's per capita income increases, participation in various leisure activities to improve the quality of life of the disabled is encouraged. However, in order to participate in leisure activities, movement to the place where the leisure activities are performed must be preceded, so interest in means of transportation for leisure activities of the disabled is increasing. Since manual and electric wheelchairs have their respective disadvantages as means of transportation for leisure activities, interest in power assisting devices for wheelchairs combining the functions of electric wheelchairs with manual wheelchairs is increasing. In this study, the FDA approval process of wheelchair power-assistance products was investigated, and the characteristics of side-attached, front-attached, downward-attached, and rear-attached types of power assist devices for wheelchairs wheelchair in countries around the world were identified. These information will be of great use in helping the disabled and their assistants in Korea to choose the optimal product according to the patient's condition. More usability tests and clinical case studies are needed so that people with disabilities can choose a power assist device suitable for them.

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.

Design and Implementation of Personal Communicator based on Embedded Single Board Computer for Controlling of Remote Devices (원격 장치 제어를 위한 임베디드 기술 기반의 개인용 커뮤니케이터 설계 및 구현)

  • Jang, Seong-Sik;Byun, Tae-Young
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.2
    • /
    • pp.99-109
    • /
    • 2011
  • This paper presents implementation details of home appliance control system using personal communicator based on LN2440 single board computer, which recognizes hand-gesture of user, controls remote moving device such as mobile home server, robot etc. through delivery of proper control commands. Also, this paper includes details of design and implementation of home gateway and mobile home server. The implemented prototype can be utilized to develop various remote control system including a remote exploration robot, intelligent wheelchair based on general purpose embedded system.

IoT Device Management Standard Protocol Trends in Mobile Communications (이동통신 기반 IoT 장치관리 표준 프로토콜 동향)

  • Oh, S.H.;Ko, S.K.;Son, S.C.;Lee, B.T.;Kim, Y.S.
    • Electronics and Telecommunications Trends
    • /
    • v.30 no.1
    • /
    • pp.94-101
    • /
    • 2015
  • 이동통신 기반 IoT(Internet of Things) 관련 표준들은 3GPP와 ETSI를 중심으로 제정되어 왔으나 2012년부터 표준의 중복을 회피하고 단일화된 표준을 통해서 IoT 시장을 성장시키고자 oneM2M이라는 국제적 협의체가 구성되었으며, 최근 Release 1 표준을 발표하는 등 IoT 표준을 사실상 주도하고 있다. Mason과 Machina 리서치에 따르면 2020년에는 동시 연결된 M2M(Machine to Machine)/IoT 장치들의 수가 21억개에 달할 것이고, 이것들이 동시에 200억개의 통신 연결을 생성할 것이다. 이런 수많은 장치들을 관리하기 위한 표준으로 OMA(Open Mobile Alliance)에서는 LWM2M(Lightweight M2M)를 제정하였다. 또한 이런 장치들은 센서들과 같이 연산능력과 배터리에 제약이 많아서 이것을 극복할 수 있는 메시지 프로토콜로 IETF에서는 CoAP 표준을 제정하였다. oneM2M에서도 CoAP과 LWM2M 표준을 채택하였고, 이를 기반으로 한 단말과 응용서비스 관리 기능이 확대될 것으로 기대된다. 본고에서는 이동통신 기반 IoT 표준 동향과 LWM2M 기반 단말 관리 규격에 대해 살펴본다.

  • PDF

Safety and Efficacy of the Mandibular Advancement Device 'Bioguard' for the Treatment of Obstructive Sleep Apnea : A Prospective, Multi-Center, Single Group, and Non-Inferiority Trial (폐쇄성 수면무호흡증의 치료에 사용되는 하악전방이동장치-'바이오가드'의 안전성과 유효성 검증을 위한 전향적, 다기관, 단일군 및 비열등성 연구)

  • Kim, Hyoung Wook;Hwang, Chungpoong;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Objectives: The purpose of this study was to estimate the safety and efficacy of a mandibular advancement device (MAD), 'Bioguard,' for the treatment of obstructive sleep apnea (OSA). Methods: In this 5-week prospective, multi-center, single group, and non-inferiority trial, patients who chose 'Bioguard' as their treatment option were evaluated using both questionnaires (Pittsburgh Sleep Quality Index (PSQI), Epworth sleepiness scale (ESS)) and polysomonography (PSG) (apnea hypopnea index (AHI), oxygen saturation). All patient data, including clinical records, PSG studies (both pre- and post-treatment), and adverse events (AEs), were reviewed and analyzed. Results: Results were obtained for 59 of 62 patients (95.16%). No significant difference in success rate was found between the MAD treatment and surgical treatment (95% CI). AHI, PSQI, ESS and oxygen saturation demonstrated significant improvement (p < 0.001) after MAD treatment, and 39 of 62 patients (62.9%) reported 85 AEs. 79 of the 85 AEs (91.8%) were mild cases, and there were no severe AEs related to the MAD treatment. Conclusion: The MAD 'Bioguard' should be considered as an alternative treatment option for OSA patients.

Application of the Total Artificial Heart as an Implantable Biventricular Assist Device by Left Thoracotomy in an Ovine Model (양에서 좌측 개흉술 하에 완전인공심장의 체내이식형 양심실 보조장치로 사용에 관한 연구)

  • 원태희;민병구;김원곤
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.296-304
    • /
    • 2001
  • 배경: 이번 연구의 목적은 체내이식형 양심실 보조장치의 개발을 위한 안전하고 간편한 동물실험 모델을 확립하는 것이며 이동작동형 완전 인공심장의 양심실 보조장치로의 사용 가능성을 알아보는 것이다. 대상 및 방법: 7마리의 Corridale 양을 대상으로 실험하였다. 5번째 늑간극을 통하여 좌측 개흉술을 시행하고 좌측 유출로 캐뉼라는 하행 대동맥에 Dacron graft을 사용하여 연결하였고 유입로 캐뉼라는 좌심방에 삽입하였다. 우측 유출로 캐뉼라는 하행 대동맥과 같은 방법으로 주폐동맥에 연결하였으며 유입로 캐뉼라는 혜동맥을 하방으로 젖혀 우심방이를 노출시킨 다음 우심방이에 삽입하였다. 4마리에 있어서는 양심실 보조장치를 전복막강(preperitoneal space)에 위치시켰으며 2마리에 촤측흉강 내에, 1마리에서는 외부에 위치시켰다. aPTT는 수술전 aPTT의 2∼2.5배로 맞추어 주었다 결과: 수술중 또는 수술직후 사망한 경우는 없었으며 7마리 모두 인공호흡기 이탈이 가능하였고 스스로 기립하고 음식물 섭취도 가능하였다. 1마리는 술후 2일째 혈전 색전증 및 인공호흡기 작동 잘못으로 사망하였으며 2마리의 겨우는 술후 2일째 각각 양심실 보조장치의 작동 잘못 및 호흡부전으로 사망하였고, 3마리의 경우는 술후 4일째 혈전색전증으로 인한 급성신부전 및 호흡부전 등으로 사망하였다. 1마리에 있어서는 28일간 생존하였으며 양심실 보조장치의 구동 장치에 연결된 라인의 마로로 인해 양심실 보조장치의 작동이 정지되었으나 바로 양심실 보조장치를 제거하고 살릴 수 있었다. 모든 경우에 있는 캐뉼라를 삽입하고 양심실 보조장치를 작동시키는데 큰 어려움이 없었다. 7마리 중 4마리에서 혈전이 발견되었으며 특히 판막을 연결한 부위에 혈전생성이 많았다. 그러나 캐뉼라에는 혈전생성이 없었다. 결론: 양에 있어서 좌측 개흉술 및 전복막강 공간에 양심실 보조장치를 위치시키는 이번 동물실험 모델은 체내 이식형 양심실 보조장치 개발을 위한 좋은 동물실험 모델이라고 생각된다. 또한 디동 작동기형 완전 인공심장의 혈전생성을 억제할수 있는 방법들의 연구개발이 지속된다면 장기간의 체내 이식형 양심실 보조장치로 사용할 수 있을 것으로 생각된다.

  • PDF

A Study on the Proper Installation Location of a Sheath Circulating Current Reduction Equipment (시스순환전류 저감장치의 적정 설치위치 검토)

  • Hong, D.S.;Jang, T.I.;Kang, J.W.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.638-640
    • /
    • 2005
  • 본 논문에서는 지중 실계통에 저감장치의 설치 위치를 다양하게 변경시켰을 경우 시스 순환전류의 변화를 분석하였으며, 그 결과 보통접속함에 저감장치를 설치하였을 경우가 절연접속함에 설치했을 경우에 비해 적은 저감효과를 보임으로써 저감장치 적용지점 선정에 있어 보통접속함의 저감장치 취부를 가능한 자제할 것으로 권하고 있는 국내 기준(안)의 타당성을 확인하였다.

  • PDF

Technology Trends in Automotive Electronic Control Units (자동차 전자제어 장치용 소프트웨어 기술 및 표준화 동향)

  • Han, T.M.;Cho, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.4
    • /
    • pp.69-82
    • /
    • 2010
  • 과거 단순한 이동 수단이 목적이었던 자동차는 더욱 안전하고 편리한 자동차, 서비스 지향 자동차로 거듭나고 있다. 점차 편리와 안전 서비스를 제공하기 위한 전자제어 장치의 장착이 확대되고 전자제어 장치간의 연동을 통한 서비스 개발이 늘고 있으며, 이로 인해 신뢰성 빛 안전성 이슈가 최근에 많이 대두되고 있다. 본 고에서는 자동차 응용 서비스의 개발에서 IT 기술들의 집합체라고 할 수 있는 전자장치용 소프트웨어의 표준 플랫폼인 AUTOSAR의 동향과 차량 전자제어 장치의 안전성 보장을 위한 ISO 26262 표준 동향 및 이슈를 살펴본다.

Design and Fabrication of Real-time Lens Testing System (실시간 렌즈 성능평가장치 설계 및 제작)

  • 이윤우;조현모;이인원;홍경희;이환규
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • 복사기. 팩스 렌즈 등 대향생산되는 광학계를 실시간에 성능평가하기 위하여 5개의 십자형 슬릿 물체와 3개의 2차원 CCD를 상분석장치로 사용한 자동평가장치를 개발하였다. 시험렌즈의 사양에 따라 물체와 렌즈, 그리고 상분석장치를 이동시키는 자동정렬장치를 제작하였으며 슬릿의 수직 및 수평방향 선분포 함수를 CCD에 의햐여 동시에 측정하였다. 그리고 렌즈의 축상 및 비축상 MTF와 배율, 편심, 그리고 회전위치에 따른 최적방향 등을 자동으로 실시간에 측정할 수 있었다.

  • PDF

Polydopamine Microfluidic System toward a Two-Dimensional, Gravity-Driven Mixing Device (폴리도파민 마이크로플루이딕시스템: 이차원, 중력이용 mixing 장치)

  • Yu, In-Seong;Lee, Hae-Sin
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.81-83
    • /
    • 2012
  • 친수성 코팅 물질인 폴리도파민을 초소수성표면에 패터닝함으로써 이차원 마이크로 플루이딕 장치 (폴리도파민 마이크로플루이딕 장치)를 만듦. 폴리도파민 마이크로플루이딕 장치는 마이크로 펌프가 없이 오직 중력만을 이용해서 액적의 이동을 가능케하는 기술임. 또한 이 장치는 매우 빠르게 액적을 손실없이 혼합시키는 기술임. 본 기술을 이용하여 금입자 반응 및 단백질 구조 분석을 수행함.

  • PDF