• Title/Summary/Keyword: 의료영상 진단

Search Result 505, Processing Time 0.027 seconds

Establishment of Standard of Property Control for Angiographic Equipments (혈관조영장비의 성능관리 기준개발)

  • 임현수;김부길
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.61-66
    • /
    • 2004
  • To make a guide line of property control of angiography equipments, we made standard evaluation sheet forms of facility and management of angiography suite, physical properties of angiography equipments, and image quality of film and then surveyed them at 29 hospital nationwide. Survey and development of standard evaluation sheet form of physical properties of angiography equipments. By using resolution & radiation dose, physical properties of angiography equipments of 49 in number nationwide were evaluated. Most of them (91%) had good performance.

Coated Tongue Region Extraction using the Fluorescence Response of the Tongue Coating by Ultraviolet Light Source (설태의 자외선 형광 반응을 이용한 설태 영역 추출)

  • Choi, Chang-Yur;Lee, Woo-Beom;Hong, You-Sik;Nam, Dong-Hyun;Lee, Sang-Suk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.181-188
    • /
    • 2012
  • An effective extraction method for extracting a coated tongue is proposed in this paper, which is used as the diagnostic criteria in the tongue diagnosis. Proposed method uses the fluorescence response characteristics of the coated tongue that is occurred by using the ultraviolet light. Specially, this method can solved the previous problems including the issue in the limits of the diagnosis environment and in the objectivity of the diagnosis results. In our method, original tongue image is acquired by using the ultraviolet light, and binarization is performed by thresholding a valley-points in the histogram that corresponds to the color difference of tongue body and tongue coating. Final view image is presented to the oriental doctor, after applying the canny-edge algorithm to the binary image, and edge image is added to the original image. In order to evaluate the performance of the our proposed method, after building a various tongue image, we compared the true region of coated tongue by the oriental doctor's hand with the extracted region by the our method. As a result, the proposed method showed the average 87.87% extraction ratio. The shape of the extracted coated tongue region showed also significantly higher similarity.

전자파 산란 및 역산란 문제의 해석 기법

  • 김세윤
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.39-46
    • /
    • 1991
  • 전자파 문제는 넓은 의미로 산란(scattering)문제와 역산란(inverse scattering)문제로 나눌 수 있다. 먼저 산란 문제는 에너지 또는 정보가 실린 전자파를 한 지점에서 다른 지점으로 보낼 때 통과하는 경로상의 매질 분포에 따라 왜곡 또는 변형되는 정도를 알아내는 것으로 반사(reflection), 굴절(refraction), 회절(diffraction)등 의 현상을 수반한다. 이 때 전자파를 왜곡시키는 물체를 산란체라고 부르며, 이러한 산란체로서는 전송선, 도파관, 광섬유 등과 같은 도파구조(guided wave structure)자체일 수 있으며 그들 내부에 고의로 부착된 첨가물일 수도 있다. 또한 공기나 지하와 같은 개방 구조 내의 물체나 비균일 매질 분포도 산란체가 될 수 있다. 이와는 반대로 역산란 문제는 알고 있는 전자파를 미지의 산란체에 가한 후, 여기서 산란된 전자파를 측정하여 얻은 자료로 부터 역으로 산란체의 위치, 크기, 모양, 매질 특성 등을 알아내는 것이다. 이러한 역산란 문제는지하 탐사(geophysical probing), 원격탐사(remote sensing), 레이다 영상(radar imaging), 의료진단(medical diagnosis), 비파괴 검사(nondestructive testing)등과 같은 많은 응용분야에 걸쳐 있다. 본 원고에서는 전자파 산란 및 역산란 문제에 대한 기존의 다양한 해석기법들을 체계적으로 분류하고, 이들의 적용범위와 한계에 대해 간략히 소개하기로 한다.

  • PDF

Metamaterials Technologies Applied for Antenna and RF Devices in Microwave (마이크로파대역에서 메타전자파구조의 안테나 및 RF 이용 기술)

  • Chong, Y.J.;Hong, J.Y.;Kim, D.H.;Ju, J.H.;Lee, W.J.;Choi, J.I.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.2
    • /
    • pp.42-56
    • /
    • 2010
  • 메타전자파구조(메타물질: MTM(Metamaterials)) 기술은 기존의 기술로는 불가능했던 주파수 독립적인 파장 위상 및 굴절률 제어가 가능한 신개념의 차세대 혁신 기술로서 정보통신기기, 전자제품 등의 초소형화, 고성능화 등의 실현이 가능하며 고성능/고효율의 전파통신 부품, 광통신 부품, 의료진단 영상장치, 보안 감시 시스템 등에 응용되어 유비쿼터스 사회의 산업 전반에 지대한 파급 효과를 미칠 것으로 보고 선진 각국에서는 차세대 핵심 원천 기술로서 개발을 경쟁적으로 추진하고 있다. 따라서 본 고에서는 이러한 기술적인 발전 추세에 맞추어 마이크로파 대역에서 MTM 설계 기술과 안테나 및 RF 부품의 성능 개선을 위한 MTM 응용 기술에 대하여 살펴보고자 한다.

Electroglottography(EGG)와 Stroboscopy

  • 최홍식
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.151-152
    • /
    • 2003
  • 말소리가 만들어지는 과정 중에서 성대에서 성대음이 만들어지는 과정이 가장 핵심적인 과정이라고 할 수 있다. 이때의 성대의 진동을 관찰할 수 있는 방법은 1) 초고속 영화 촬영(Ultra-speed cinematography), 2) 스트로보스코피(Stroboscopy), 3) 성문파형검사(Glottography) 등이 사용되어 왔다. 1)은 고가의 장비이며 분석도 어려워서 아주 극소수의 연구기관에서만 부분적으로 사용되어 왔고, 2)와 3)은 임상에서 그리고 연구실에서 널리 사용되어 왔다. 스트로보스코피의 영상을 비디오로 녹화하는 장비는 이제는 이비인후과 영역에서 웬만한 종합병원급 의료기관 이라면 거의 필수적인 장비로 자리잡고 있다 그만큼 성대의 미세한 병변에 대한 진단적 가치가 높다고 할 수 있겠다. 스트로보스코피는 끊어져서 발생되는 제논 광선이 내시경을 통하여 성대에 전해지고, 성대의 실제의 진동 보다. 아주 느리게 움직이는 것 같은 일종의 허상이 화면에 나타나고 이를 비디오시스템으로 저장하여 관찰하는 것이다(Fig. 1, 2). (중략)

  • PDF

Source Estimation of Digital Filter System using Inverse Problem (역문제: 2차원 전자파 산란문제)

  • Kim, Tae Yong;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.47-48
    • /
    • 2014
  • Non-destructive technique to measure internal structure and constant distribution of material can be widely used to exploration of mineral resources, identification of underground cables and buried pipelines, and diagnostic imaging in medical area. In this paper, inverse scattering solution based on 2-dimensional EM scattering problem should be considered and formulated.

  • PDF

Estimation of Far-field Radiation by 2-Dimensional EM Scattering (2차원 전자파 산란에 따른 방사패턴의 추정)

  • Kim, Tae Yong;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.51-52
    • /
    • 2014
  • Non-destructive technique to measure internal structure and constant distribution of material can be widely used to exploration of mineral resources, identification of underground cables and buried pipelines, and diagnostic imaging in medical area. In this paper, we considered 2-dimensional EM scattering problem. Radiation pattern in far field is estimated by using some measured information obtained from near-field solutions.

  • PDF

Source Estimation in Near-field by 2-Dimensional EM Scattering (2차원 전자파 산란에 따른 근방계에서의 소스 추정)

  • Kim, Tae Yong;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.59-60
    • /
    • 2014
  • Non-destructive technique to measure internal structure and constant distribution of material can be widely used to exploration of mineral resources, identification of underground cables and buried pipelines, and diagnostic imaging in medical area. In this paper, we considered 2-dimensional EM scattering problem. Incident wave source is estimated by using some measured information obtained from near-field solutions.

  • PDF

Proposal of a Method the Comparing and Analysis of Face Color Meter (안면 색 비교 분석 방법의 제안)

  • Lee, Se-Hwan;Kim, Bong-Hyun;Ga, Min-Kyung;Cho, Dong-Uk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.486-489
    • /
    • 2010
  • 본 논문에서는 안면 색 비교 분석을 위한 방법 및 시스템을 제안 한다. 안면 색 비교 분석은 의료 및 여러 분야에서 요구가 증가 하고 있으나 현재 개발되어 있는 시스템은 거의 없는 실정이다. 이에 안면색 비교 분석 시스템의 개발을 통해 여러 분야에 있어 활용이 가능할 것으로 사료 된다. 이는 각 분야에서 실험 전 후의 안면 영상 비교에 있어 활용도가 높으며, 특히 한의학의 진단법 중 망진의 색진을 위한 안면 색 분석에 있어 효율적인 분석을 행 할 수 있을 것으로 사료된다.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.