• Title/Summary/Keyword: 의료영상분석

Search Result 513, Processing Time 0.028 seconds

A management system for plural viewing coordinates of multiplanar reformation (의료영상 시스템의 다중 단면 재구성을 위한 좌표계 제어 시스템)

  • Kim, Jun-Ho;Kye, Hee-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.2
    • /
    • pp.163-170
    • /
    • 2010
  • Multi-planar reformatting(MPR) is a volume rendering technique which generates images of sectional planes users define, so that it is essential for medical imaging system. Due to the recent advances of medical imaging system, users require to place plural planes on a single dataset and to enable an individual and easy control for each plane. In this paper, we enumerate various user operations for recent MPR and analyze user requirements to update the plane equation. For the effective control of coordinate system, each plane is considered in a separated coordinate system and all informations which form a coordinate system are grouped into two components: the individual components and the common components. The proposed system is implemented on a graphics hardware, so that it smoothly performs MPR including recent requirements.

A Discussion on Image Analysis in 18F-Florbetaben PET/CT (18F-Florbetaben PET/CT 검사에서 영상분석에 대한 고찰)

  • Choi, Yong-Hoon;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.33-37
    • /
    • 2022
  • Purpose 18F-Florbetaben (FBB) Readings are made by visually comparing the signal strengths of gray matter and white matter. We intend to evaluate the usefulness of image analysis by comparing quantified image analysis with readout. Materials and Methods Based on the reading results, 100 patients were divided into a negative scan and a positive scan, and 300 MBq of FBB was injected, and images were taken 90 minutes later for 20 minutes. The equipment was a Discovery 600 (GE Healthcare, MI, USA). Four regions of interest (lateral temporal lobes, frontal lobes, posterior cingulate & precuneus, and parietal lobes) were established based on the amyloid reading standard provided by the manufacturer. For image analysis, SUVratio (SUVr) was calculated by dividing each SUVmean by the cerebellum, and the average SUVr in the entire area was performed. Statistical analysis analyzed the cutoff derivation through ROC Curve, the difference between groups in Independent sample t-test, and the degree of agreement with the reading result through Kappa test. Results The average SUVr cutoff in the entire area was 1.23. Concordance with the read results using cutoff was 95/100 (95%) for negative and 92/100 (92%) for positive. As a result of the t-test, there was a statistically significant difference between the groups (P < 0.05), and the Kappa statistical result showed a high degree of agreement with 0.867 (P < 0.05). Conclusion The results of image analysis were statistically significant and showed a high degree of agreement with the reading results. In addition, FBB image analysis can be viewed by 3D mapping the area where amyloid is accumulated, location estimation is possible, and quantitative analysis results can be viewed in detail. If quantified FBB image analysis is used as an auxiliary indicator, it is thought to be helpful in reading.

Feature Extraction and Image Segmentation of Mechanical Structures from Human Medical Images (의료 영상을 이용한 인체 역학적 구조물 특징 추출 및 영상 분할)

  • 호동수;김성현;김도일;서태석;최보영;김의녕;이진희;이형구
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.112-119
    • /
    • 2004
  • We tried to build human models based on medical images of live Korean, instead of using standard data of human body structures. Characteristics of mechanical structures of human bodies were obtained from medical images such as CT and MR images. For each constitutional part of mechanical structures CT images were analyzed in terms of gray levels and MR images were analyzed in terms of pulse sequence. Characteristic features of various mechanical structures were extracted from the analyses. Based on the characteristics of each structuring element we peformed image segmentation on CT and MR images. We delineated bones, muscles, ligaments and tendons from CT and MR images using image segmentation or manual drawing. For the image segmentation we compared the edge detection method, region growing method and intensity threshold method and applied an optimal compound of these methods for the best segmentation results. Segmented mechanical structures of the head/neck part were three dimensionally reconstructed.

  • PDF

The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System (의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구)

  • Kang, Sang Sik;Kim, Kyo Tae;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.589-596
    • /
    • 2019
  • X-rays used for diagnosis have a continuous energy distribution. However, photons with low energy not only reduce image contrast, but also contribute to the patient's radiation exposure. Therefore, clinics currently use filters made of aluminum. Such filters are advantageous because they can reduce the exposure of the patient to radiation. However, they may have negative effects on imaging quality, as they lead to increases in the scattered dose. In this study, we investigated the effects of the scattered dose generated by an aluminum filter on medical image quality. We used the relative standard deviation and the scatter degradation factor as evaluation indices, as they can be used to quantitatively express the decrease in the degree of contrast in imaging. We verified that the scattered dose generated by the increase in the thickness of the aluminum filter causes degradation of the quality of medical images.

A Design and Implementation of Volume Rendering Program based on 3D Sampling (3차원 샘플링에 기만을 둔 볼륨랜더링 프로그램의 설계 및 구현)

  • 박재영;이병일;최흥국
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.5
    • /
    • pp.494-504
    • /
    • 2002
  • Volume rendering is a method of displaying volumetric data as a sequence two-dimensional image. Because this algorithm has an advantage of visualizing structures within objects, it has recently been used to analyze medical images i.e, MRI, PET, and SPECT. In this paper. we suggested a method for creating images easily from sampled volumetric data and applied the interpolation method to medical images. Additionally, we implemented and applied two kinds of interpolation methods to improve the image quality, linear interpolation and cubic interpolation at the sampling stage. Subsequently, we compared the results of volume rendered data using a transfer function. We anticipate a significant contribution to diagnosis through image reconstruction using a volumetric data set, because volume rendering techniques of medical images are the result of 3-dimensional data.

  • PDF

Study of machine learning model for predicting non-small cell lung cancer metastasis using image texture feature (Image texture feature를 이용하여 비소세포폐암 전이 예측 머신러닝 모델 연구)

  • Hye Min Ju;Sang-Keun Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.313-315
    • /
    • 2023
  • 본 논문에서는 18F-FDG PET과 CT에서 추출한 영상인자를 이용하여 비소세포폐암의 전이를 예측하는 머신러닝 모델을 생성하였다. 18F-FDG는 종양의 포도당 대사 시 사용되며 이를 추적하여 환자의 암 세포를 진단하는데 사용되는 의료영상 기법 중 하나이다. PET과 CT 영상에서 추출한 이미지 특징은 종양의 생물학적 특성을 반영하며 해당 ROI로부터 계산되어 정량화된 값이다. 본 연구에서는 환자의 의료영상으로부터 image texture 프절 전이 예측에 있어 유의한 인자인지를 확인하기 위하여 AUC를 계산하고 단변량 분석을 진행하였다. PET과 CT에서 각각 4개(GLRLM_GLNU, SHAPE_Compacity only for 3D ROI, SHAPE_Volume_vx, SHAPE_Volume_mL)와 2개(NGLDM_Busyness, TLG_ml)의 image texture feature를 모델의 생성에 사용하였다. 생성된 각 모델의 성능을 평가하기 위해 accuracy와 AUC를 계산하였으며 그 결과 random forest(RF) 모델의 예측 정확도가 가장 높았다. 추출된 PET과 CT image texture feature를 함께 사용하여 모델을 훈련하였을 때가 각각 따로 사용하였을 때 보다 예측 성능이 개선됨을 확인하였다. 추출된 영상인자가 림프절 전이를 나타내는 바이오마커로서의 가능성을 확인할 수 있었으며 이러한 연구 결과를 바탕으로 개인별 의료 영상을 기반으로 한 비소세포폐암의 치료 전략을 수립할 수 있을 것이라 기대된다.

  • PDF

Development of medical image management and labeling system for the diagnosis of dysphagia (삼킴 장애 진단을 위한 의료영상 관리 및 라벨링 시스템 개발)

  • Lim, Dong-Wook;Lee, Chung-sub;Noh, Si-Hyeong;Park, Chul;Kim, Min Su;Jeong, Chang-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.322-325
    • /
    • 2022
  • 삼킴 장애 환자는 뇌졸중, 치매, 외상성 뇌손상, 파킨슨병, 암이 주요 원인으로 급속히 증가하고 있다. 특히 고령화 사회가 되면서 더욱 삼킴 장애 환자는 늘어날 것으로 전망하고 있다. 고령 환자의 삼킴 이상의 진단을 위해 가장 많이 사용하고 있는 검사법으로는 비디오 조영 삼킴 검사(VFSS)이다. VFSS는 진단에 있어서 숙련된 전문의가 필요하기 때문에 대학병원 급에서 주로 시행하며, 고령 환자에게는 분석 결과를 상담받을 때까지 오랜 시간을 소요해야하는 문제점들이 있다. 본 논문에서는 삼킴 장애 진단을 위한 의료영상 관리 및 라벨링 시스템에 대해서 기술한다. 이를 구현하기 위해 서버에서 대용량 멀티프레임 영상을 성능 저하 없이 핸들링 하고 라벨링 데이터 생성을 위한 라벨링 툴을 구현하였다. 차후 라벨링 데이터를 생성하고 학습을 통하여 삼킴 장애 진단을 위한 인공지능 모델을 개발하고자 한다.

Multimodality Nonlinear Medical Image Registration based on Surface Information & Voxel Similarity (표면 및 복셀 유사성 기반 다중모달리티 비선형 의료영상정합)

  • Kim, Min-Jeong;Kim, Myoung-Hee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.1633-1636
    • /
    • 2005
  • 의료영상정합은 환자의 해부학적 정보와 기능적 정보를 혼합함으로써 기능이상부위의 해부학적 위치를 판별하기 위한 목적으로 널리 이용되고 있다. 그러나 실제적으로 여러 종류의 환자영상 취득이 어렵거나 해부학적 영상정보가 손실되는 경우가 적지 않다. 따라서 표준 정상인 해부학적 영상과 환자 기능영상을 정합함으로써 보다 객관적인 환자 기능이상부위 분석이 요구된다. 이는 다중개체, 다중모달리티간 영상정합으로 기존의 표면정보 또는 복셀정보 기반 방법으로는 한계가 있다. 따라서 본 연구에서는 두 대상영상 표면 뿐 아니라 내부 볼륨까지 대응시킬 수 있는 표면정보와 복셀정보를 혼합 적용한 기법을 제안한다.

  • PDF

A Study on the Structural Relation among Purchase Decision Factors of Medical Devices, Satisfaction and Repurchasing Intention : Focused on Ultrasound Imaging System (의료기기의 구매결정요인과 만족 및 재구매 의도의 구조적 관계에 관한 연구 : 초음파영상진단장치를 중심으로)

  • Jung, Tae-young;Seo, Geon-seok;Kim, Su-beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3308-3314
    • /
    • 2015
  • The purpose of this study is to investigate the casual relationships among purchase decision factors of medical devices, satisfaction and repurchasing intention. Data of this study is a 2012 survey on medical institutions using medical devices of MW(ministry of health and welfare) and We analyzed 116 medical institutions having ultrasound imaging system lager than general hospitals among data. For empirical analysis, we carried out confirmative factor analysis and path-analysis using AMOS 21.0 package. Main results of this study are as follows: First, brand has positive influence on satisfaction and satisfaction has positive impaction on repurchase intention. Second, although not statistically significant, performance and service have positive impaction on satisfaction and price has negative influence on satisfaction. The significance of this study is to provide empirical basis on establishment of efficient marketing strategy and enhancement of competitiveness for the medical device industry.

Extract and Analysis System for CT/MRI Images (CT/MRI 영상에서의 이미지 추출-분석 시스템)

  • Kwak, Ho-Young;Huh, Jisoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.1
    • /
    • pp.131-140
    • /
    • 2014
  • TMost of the medical images that are being used today are to confirm the existence of lesions. These kind of medical images can not only be used to confirm lesions but if we could use it for academic studies or for analysis and reference materials for surgical operations, it could offer great help in medical studies. Furthermore, we could reduce the number of errors in treatment through simulations in the surgical operations and treatments. In this paper, the necessary parts regarding the medical image visuals were extracted through the point cloud and by using the information obtained through it, it manufactures the necessary information for academic studies, diagnoses or operations. By designing and realizing the system which makes simulation possible with the manufactured information, the paper attempts to provide a more effective way to approach academic studies or giving appropriate diagnoses in the treatment of patients.