• Title/Summary/Keyword: 응집제 주입량

Search Result 99, Processing Time 0.03 seconds

Evaluation of Coagulation-UF Process Considering Residual Aluminuim Concentration as Seawater Desalination Pretreatment (해수담수화 전처리 공정으로써 잔류 알루미늄 농도를 고려한 응집-UF 공정 연구)

  • Son, Dong-Min;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.495-502
    • /
    • 2013
  • This work was performed to investigate proper condition of coagulation treatment as UF process pretreatment that consider UF permeate flux and residual Al concentration. The coagulant used an alum as $Al_2(SO_4)_3{\cdot}16H_2O$ and PACl (r = 1.5) made this study. The experiment was tested in adjusting conditions such as alum dose, flocculation time and coagulation pH of seawater. Consequently, higher coagulant dose lead to elevation of UF permeate flux while residual aluminium also increased in condition of pH 8.0. The most suitable condition which has a good permeate flux and low residual aluminium, in this works, was coagulant dose of 0.7 mg/L (as Al, alum) and 1.2 mg/L (as Al, PACl) and coagulation pH 6.5. In addition, applying the flocculation time with 1.2 mg/L of PACI reduced. The flocculation time reduced UF permeate flux in using alum.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.

Characteristics of Coagulation-Flocculation-Sedimentation Process with BAF Process on Drinking Water Treatment using Nakdong River Water (BAF와 연계한 응집.침전공정에 의한 정수처리 특성)

  • Ko, Su-Hyun;Choi, Jeung-Woo;Hyun, Kil-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.237-243
    • /
    • 2000
  • 최근에 경제성장과 생활향상에 따른 물수요량이 급증함과 동시에 소비자의 질적요구가 강화되고 있는 실정이다. 기존 상수원인 하천의 수질오염으로 인하여 소비자의 요구사항을 충족시키기 위해서는 기존 정수처리법의 개선이 요구된다. 따라서 본 연구에서는 기존 급속여과법의 전염소 처리공정 및 응집.침전 공정의 개선을 통하여 음용수 수질을 개선하고자 하였다. 전염소 대신에 적용한 생물막여과 공정(BAF)의 처리효과 및 응집.침전 공정의 경우는 교반강도에 따른 침전효과에 따른 수질특성을 조사하였다. BAF공정은 탁월한 $NH_4$-N의 제거를 통하여 후속공정에 대한 오염부하량을 저감시킬수 있었고, 응집.침전의 경우 본 연구에서 제안한 응집제 주입량에 따른 교반강도의 실험식인에 의하여 구한 최적교반강도용 용집공정에 적용시 응집.침전의 효과를 향상시킨 수 있어 음용수 수질 향상을 기대 할 수 있었다.

  • PDF

A Study on the improvement of Chemicals Dosing Performance using Neural network in a Purification Plant (신경회로망을 이용한 상수처리설비의 약품주입 성능개선에 관한 연구)

  • 류승기;최도혁;홍규장;문학룡;한태환;유정웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.104-113
    • /
    • 1998
  • In genral, the water process facilities include the purification plant, the waste water plant and the process of this purification plant is consisted of the intake, coagulation, settling, filtration, disinfection. The coagulation is very important in filtration processing plant and is very related to process of turbidity. The coagulation to the turbidity is, however, not yet to be clarified and the amount of coagulant can not be easily calculated. Moreover the coagulant dosing amount has to be decided adaptively according to the qualities of the raw water. So, the automation of chemicals dosing process and the supervisory system were needed to improve the performance of facilities. In this paper, a neural network is employed to model the coagulation to the turbidity of the treated water and the historical jar-test data are used to train the neural network. And also, an automation system to support the coagulant dosing process using the neural network was implemented and was shown by the field test. This automation system for the operator support system was constructed the environment to supervise the state an management of facilities for the maintenance.

  • PDF

The Effect of Algae on Coagulation and Filteration of Water Treatment Process (정수처리과정중 응집및 여과에 미치는 조류의 영향)

  • Lim, Young-Sung;Song, Won-Seb;Cho, Ju-Sik;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • Seasonal variations of dominant algae species and the effects of these algae on coagulation and filteration of water treatment were investigated at Chilseo water treatment plant in downstream of Nakdong river from January in 1995 to Desember of 1998. The water quality of Nakdong river was found to be a hyper eutrophic state during the investigation periods. In the measurement, Chlorophyll-a contents ranged $20.7{\sim}180.9{\mu}g/l$ and total nitrogen contents(T-N) and total phosphorus contents(T-P) exceeded more than 3.4mg/l and 0.1mg/l, respectively. The changes in dominant algae species was in the order of Stepanodiscus sp., Asterionella sp., Melosira sp., Microcystis sp. and Synedra sp. from spring to winter. Microcystis sp. especially, was blooming during summer and Synedra sp. and Stepanodiscus sp. during winter. Although most diatomous algae appeared in the water treatment process caused filter clogging and reduced efficiency of coagulation and sedimentation, Synedra sp. and Stepanodiscus sp were revealed as the main trouble algae. Malfunction of water treatment process caused by Synedra sp. and Stepanodiscus sp. started at the algae concentrations of 800cells/ml and 1,820cells/ml, respectively. When chlorophyll-a content was $18.9{\mu}g/l$, the optimum amounts of coagulant were found to be 40mg/l of Alum and 16mg/l of PACS. Under condition of chlorophyll-a content of $154.1{\mu}g/l$, addition of Alum at the level of 75mg/l and PACS at the level of 35mg/l showed the lowest turibidity. The result indicates that increased amounts of the coagulants should be added for a better water treatment as chlorophyll-a contents increased. Addition of Alum at the amount of 60mg/l and 30mg/l of PACS removed Stepanodiscus sp. algae at the rate of 85% and 83%, respectively. In case of Synedra sp., 50mg/l of Alum and 25mg/l of PACS showed removal rates of 79% and 81%, respectively. Synedra sp. algae at the standing crops of 1,500cells/ml started filter clogging and a filtering process was completely inhibited after 8 hours. At this situation the filter clogging by Synedra sp. algae occurred at the depth of 5cm from the top anthracite layer. On the other, other algae did filter clogging at the depth of 10cm.

  • PDF

Removal of Dissolved Organic Nitrogen from Surface Water and Reclaimed Water by Coagulation (지표수 및 재이용수내 용존 유기질소의 응집처리)

  • Lee, Wontae;Choi, June-Seok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.729-734
    • /
    • 2012
  • During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.

Performance characteristics of inline mixing and coagulation system (인라인 혼화 및 응집 시스템의 성능특성)

  • Kim, Dong-Jun;Park, Sang-Kyoo;Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.269-275
    • /
    • 2014
  • The objective of this study was to investigate the performance characteristics of an inline mixing and coagulation system for water treatment based on the process intensification concept. Three-stage inline mixing and coagulation system was composed of the reservoirs of source wastewater, the fixed quantity injection pumps of coagulants, the mixing and coagulation tubes, a sedimentation tank and a control panel. In the equal dosage of coagulant and coagulant aids, the turbidity removal with increasing the dosage of coagulant aids was about 3 times higher than that with increasing the dosage of coagulant. In the condition of the equal mixing and coagulation time, the turbidity removal of inline mixing and coagulation system was about 4.6 times higher than that of mechanical type.

Removal of Color from a Biological Piggery Wastewater Treatment Effluent by Chemical Coagulation (화학적 응집을 이용한 생물학적 돈분폐수 처리수의 색도제거)

  • Park, Noh-Back;Seo, Tae-Kyeong;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1047-1053
    • /
    • 2008
  • This study was to evaluate the optimum conditions for chemical coagulation to remove color from the effluent of a piggery wastewater treatment process. The DOC concentration in the effluent was about 227.3 mg/L, color was 2,430 CU, turbidity was 22.1 NTU, and UV$_{254}$-absorbance was 3.7 cm$^{-1}$. The fractions of hydrophobic, transphilic, and hydrophilic substance of the effluent was about 55.3%, 17.4%, 27.3% respectively. Also, molecular weight cut-off(MWCO) of below 0.5 K, 0.5 K to 1 K, 1 K to 10 K, 10 K to 30 K, and over 30 K were 74.2%, 7.3%, 5.5%, 7.1%, and 5.9% respectively. SCD(streaming current Detector) was used to find out the optimum pH values and coagulant dosages. The optimum dosages and pH of Al$^{3+}$ were 5.84 mM and 5.3, while those of Fe$^{3+}$ were 9.25 mM and 5.0, respectively. At optimum conditions of coagulation, color removal efficiencies for aluminium sulfate and ferric chloride were as high as 91.9 and 98.7%, respectively. Chemical coagulation showed good performance to remove color from on biologically treated piggery wastewater.

Treatment of Livestock Wastewater with Coagulant-loess (황토를 이용한 축산폐수의 처리에 관한 연구)

  • Park, Jin-Hee;Kim, Bo-Guk;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1799-1808
    • /
    • 2000
  • To investigate the applicability of loess as a coagulant. the optimum conditions of coagulation and efficiency comparison of several coagulants (PAC, PACS, LAS) in chemical treatment of livestock wastewater were performed. As a result, the optimum mixing ratio of loess and lime(CaO) was 3:7. The optimum dosage of the mixed coagulant was 30 g/L. The optimum speed for rapid mixing of the mixed coagulant was 200 rpm at 1 min. and the optimum speed for slow mixing was 50 rpm at 10 min. The mixed coagulant showed the removal efficiency of turbidity, SS, BOD, $COD_{cr}$. T-P and TKN to 95.8%, 92.5%, 71.6%, 71.1%, 98.2% and 32.5%, respectively, which was better than other several coagulants. The mixed coagulant was possible to use as substitutional coagulants of traditional coagulant, and the producted sludge can use as a soil amendments.

  • PDF

Effect of Coagulation in Coagulation/Ultrafiltration Hybrid System in Water Treatment Process (정수처리용 응집.한외여과 혼성공정에서 응집 효과에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyub;Kim, Seung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.837-843
    • /
    • 2005
  • Coagulation influence was evaluated as the pretreatment for ultrafiltration. Coagulation was expected to improve water quality, reduce membrane fouling and increase backwash effect. Continuous operation of UF was employed in order to investigate the influence of coagulation. Alum, PACS and Ferric chloride were used as coagulants separately. From the result of the research, coagulation can improve the treated water quality greatly. Organic removal was increased more than turbidity and showed an improvement of 30.6% at most. All three coagulants presented conspicuous reduction of membrane fouling, among which PACS was the most effective with long term run. Backwash effect differed with different coagulants while Ferric chloride turned out to be the most effective one. The optimum dosage of coagulant resulted in the highest backwash efficiency.