Abstract
During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.
용존유기질소(DON)는 염소와 반응하여 인체에 유해한 질소계 소독부산물과 소독능을 저하시키는 유기성 클로라민을 생성할 수 있다. 이러한 물질의 생성을 줄이기 위해서는 소독공정 전에 DON의 제거가 필요하다. 본 연구는 DON을 함유하는 지표수와 재이용수를 이용하여 응집실험을 하고 알루미늄염(alum)과 고분자응집제(polyDADMAC)에 의한 DON의 제거특성을 조사하였다. 또한 DON, 용존유기탄소(DOC), 254 nm 자외선 흡광물질($UVA_{254}$)의 제거율 및 제거 기작을 비교하였다. 지표수와 재이용수 모두 alum 응집제의 주입농도를 증가시킴에 따라 DON, DOC, $UVA_{254}$ 제거율이 점진적으로 증가하였는데, 원수특성과 상관없이 소수성 유기물을 나타내는 척도인 $UVA_{254}$의 제거율이 가장 높았다. 지표수와 재이용수 모두 alum 응집제만 주입한 경우보다 고분자응집제를 같이 주입한 경우 DON의 제거율이 높게 나타났다. 고분자응집제의 전하중화가 작용하는 적정농도범위가 좁아 고분자응집제만 주입하기 보다는 무기응집제와 같이 주입하는 하는 것이 바람직하다. 상대적으로 생성된 후 오랜 시간이 지나지 않은 재이용수의 DON 제거율이 지표수의 DON 제거율보다 높았고, 지표수와 재이용수 모두 10,000 Da 이상 분자량의 DON 제거율이 높게 나타났다.