• Title/Summary/Keyword: 음용수 수질기준

Search Result 62, Processing Time 0.029 seconds

Effects of Farming Practice and NO3-N Contents of Groundwater with Different locations under Intensive Greenhouse Area (시설재배지의 재배방법 및 입지적 조건이 지하수 NO3-N 함량에 미치는 영향)

  • Ko, Jee-Yeon;Lee, Jae-Sang;Kim, Min-Tae;Kim, Choon-Song;Kang, Ui-Gum;Kang, Hang-Won
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate effects of fanning practice and $NO_3-N$ contents of groundwater in intensive horticultural greenhouse area of Yeongnam province, the groundwater samples from 1,370 sites were collected and analyzed. In addition, cultivation year, crops, desalinization methods, amounts of manure application, tube well depth and soil texture with clay contents were observed. Of the investigated sites, 19.7% of shallow groundwater and 1.3% of confined groundwater were exceeded over $10mg/{\ell}$ as the $NO_3-N$ drinking limit value, respectively. $NO_3-N$ concentration in groundwater was highly significantly correlative with clay content $(r=-0.241^{**})$, well depth $(r=-0.228^{**})$ and cultivation duration $(r=0.104^*)$, respectively. In case of desalting crop method being executed for desalinization of greenhouse soil, the $NO_3-N$ value of groundwater was lower than any other desalinization method. The fact that $NO_3-N$ contents of confined groundwater was affected by shallow groundwater was clarified by that $NO_3-N$ contents in shallow were significantly correlative with the confined groundwater $(r=0.532^{**})$.

A development of integrated water-quality measurement system (통합 수질계측 시스템 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.211-216
    • /
    • 2007
  • The quality of tap water on the whole water-supply system, from a large filtration plant to a private faucet, has to be guaranteed the standards of drinking water. At this point in time, however, the supply process of the tap water has not been monitored and managed scientifically. The piped water, especially the most small-scale reservoirs(underground or overhead type) are always exposed to various contaminations and impurities. Recently monitoring systems of water-quality were spread on some large filtration plants or distributing reservoirs. In particular, the water quality monitoring method using the internet is adopted into some local government whose inhabitants can check up the water quality anytime and anywhere. The construction of this system that has to apply a large scale needs, and has a limitation on the small water-supply system, such as apartments, public facilities and small-scale underground or overhead reservoirs. In this work, we suggest the integration system of individual water-quality sensor modules that have a low price. By using the developed integration system and monitoring program operated on the internet, the system managers of reservoirs can monitor and manage water-quality characteristic values of drinking water in online. Since the proposed system was modularized, the system can be applied easily into various reservoirs with a low cost and regardless of its scale, small or large.

  • PDF

Effect of Green Tea Beverage for the Removal of Cadmium and Lead by Animal Experiments (동물실험에 의한 녹차음료의 카드뮴 및 납 제거효과)

  • Choi, Sung-Inn;Lee, Jung-Hi;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.745-749
    • /
    • 1994
  • Animal experiments were conducted to confirm the suppressive effect of green tea on the intestinal absorption and tissue accumulation of toxic heavy metals in rats. When drinking water contaminated with 500 and 5000 times level of water quality standard for lead or cadmium was administrated to rats for 3 weeks, feed intake and body weight gain were not significantly differrent among all groups except for high cadmium group. In the relative weights of target organs, kidney and femur showed a significant difference by heavy metal administration and green tea did not influence on the weights. Green tea showed a suppressing effect on the accumulation of heavy metals in target organs, in which the reducing effect in femur was $25{\sim}45%$ for lead, and 42% for cadmium. As calcium content of femur decreased by heavy metal administration was increased in green tea group, it was concluded that heavy metal accumulation in femur was interrupted by tea beverage.

  • PDF

Analysis of mine tailings, soils, stream sediments and ground water around Imcheon disused mine (임천광산 광미와 주변 토양 및 지하수의 오염조사)

  • 김선태;윤양희;박제안;심의섭;박경수
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.33-44
    • /
    • 1998
  • Mine tailings, soils, stream sediments, and ground water around Imcheon disused mine were analyzed in order to investigate their pollution levels of heavy metals and cyanide. The average contents of As, Cd, Cu, Hg, Pb, Zn, and CN ̄ in mine tailings were 366, 28.8, 202, 15.2, 1.97$\times$$10^3$, 3.85$\times$$10^3$, 90.6mg/kg respectively, The pollution indices that calculated by the tolerance level of Kloke were 8~19 and the pH values were acidic in mine tailngs. In the field and paddy soils of Imcheon disused mine area except for soils nearby mine tailngs, concentraitons of the heavy metals were less than standards of soil pollution of agricultral area in the environmental protection law. The nitrate contents In the ground water for drink were more than tolerance level of the drinking water of Ministry of Health and Social Affairs.

  • PDF

Physico-chemical and Microbiological Analysis of Tap Water in the Apartment in Taegu City (대규모 음용수 저장시설의 수질평가)

  • Kim, Seck-Bhum;Kang, Pock-Soo;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.69-75
    • /
    • 1988
  • The drinking water in the apartment is stored in reservior tank and thereafter supplied each household. In case the drinking water is stored too long or insanitary, tap water might change in quality. This study was carried out to evaluate the physico-chemical and microbiological conditions of 36 samples of tap water of apartments compared to 18 samples of tap water of independence houses in Taegu City from May to October, 1987. Main findings are summarized as follows : PH values were within normal range in all samples. Samples less than 0.2ppm in residual chlorine accounted for 16.7% in the appartment and 5.6% in the independence house. Nitrite nitrogen was detected 2.8% of apartment samples only. Among the total of 54 samples, 11.1% of the apartment and independence samples were over the normal value in standard plate count. Samples more than 1.8 of most probable number(MPN) accounted for 27.8% in the apartment and 33.3% in the independence house. In result of test for residual chlorine, nitrite nitrogen, standard plate count, and MPN, the proportion of the samples revealed inappropriated in respect of drinking water standards. In case of all sorts of tests was 2.7% in apartment and nothing in independence houses, in case of 3 sorts of tests was 2.7% in apartment and 5.6% in independence houses, in case of 2 sorts of tests was 8.3% in apartment and 5.6% in independence houses, and in case of only 1 test was 25.0% in apartment and 22.2% in independence houses. Correlation between residual chlorine and standard plate count, and between standard plate count and MPN were observed. It was found that the more years since construction of apartment were, the worse tap water was in quality.

  • PDF

Concentrations of the Pollutants in Ground Water and their Behavior in Soils in Cheju Island;II. Nitrate-nitrogen concentration and tis relation to other ions in ground water near the district of pig arming complex in the northwest region (제주도 지하수중 오염물질의 농도와 토양중 그의 행동에 관한 연구;Ⅱ. 서북부지역 양돈단지 주변 지하수중의 $NO_3-N$ 농도와 다른 이온과의 관계)

  • Hyun, Hae-Nam;Koh, Seung-Hak;Oh, Sang-Sil
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.151-159
    • /
    • 1994
  • This study was conducted to investigate the $NO_3-N$ concentration, the relationship between $NO_3-N$ and other ions, and patterns of ions in ground water used as drinking water in Cheju Island. Samples were collected from 19 wells in the northwest region, near the district of poultry complex, and 9 wells in the northeast region. In the northwest region, $NO_3-N$ concentrations in D-14 and D-202 wells near the pig farming facilities were 10.95 and 13.1 mg/L, respectively, exceeding the standard concentration of drinking water. The concentration in D-65, D-35, and D-120 wells were slightly lower than the standard concentration. However, $NO_3-N$ concentrations in the wells in the northeast region were lower than 3mg/L. In wells in the northwest region, $NO_3-N$ concentrations were negatively correlated with pH and positively correlated with $Ca^{++}$, $Mg^{++}$, $Na^+$ $Cl^-$, $SO_4^{--}$, and $Cl^-/HCO_3^-$. However, in the northeast region, they were not related with pH and the ions. The chemical compositions in D-65, D-35, and D-41 wells showed higher concentrations of $Ca^{++}$, $Mg^{++}$, $Na^+$, $Cl^-$, $NO_3-N$ and $SO_4^{--}$ than the unpolluted D-42 well. These results suggest that ground water near the pig farming complex was polluted by pig farming waste in the northwest region.

  • PDF

International Trends for Radionuclides Management in Drinking water (선진 외국에서의 먹는물 중 방사성물질 관리동향)

  • Park, Sun-Ku;Son, Ji-Hwan
    • Journal of Environmental Policy
    • /
    • v.5 no.2
    • /
    • pp.49-67
    • /
    • 2006
  • The radionuclides in drinking water have been regulated in many countries. In USA, the regulation has been revised for over 30 years since radionuclides have been regulated under Safe Drinking Water Act(SDWA) from 1974. Today, USEPA is finalizing maximum contaminant level goal(MCLG) of zero for radionuclides, maximum contaminant level(MCL) and alternative maximum contaminant level(AMCL) of 300pCi/L and 4,000pCi/L for radon respectively, MCLs of $30{\mu}g/L$ for uranium, and MCLs of 5pCi/L for combined radium 226 and 228. In Canada, Maximum Acceptable Concentration(MAC) value for uranium is $20{\mu}g/L$. WHO revised the guideline value of uranium and radon to $15{\mu}g/L$ and 100Bq/L in september 2004, respectively. On this survey, it has been found that international regulations for radionuclides in drinking water have been established and improved steadily on the knowledge basis from the past decades' studies.

  • PDF

Natural Baseline Groundwater Quality in Shingwang-myeon and Heunghae-eup, Pohang, Korea (포항시 신광면 및 흥해읍 일대 지하수의 배경수질 연구)

  • Lee, Hyun A;Lee, Hyunjoo;Kwon, Eunhye;Park, Jonghoon;Woo, Nam C.
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.469-483
    • /
    • 2020
  • The results of long-term groundwater level and quality monitoring can be used not only as the basic data for evaluating the impact of various disasters including climate change and establishing responses, but also as key data for predicting and managing geological disasters such as earthquakes. Some countries use groundwater level and quality monitoring for researches to predict earthquakes and to assess the impacts of the earthquake disaster. However, a few cases in Korea report on individual groundwater quality factors (i.e., dissolved ions) observed before and after the earthquakes, being different from other countries. To establish the abnormality criteria for groundwater quality in Pohang, groundwater samples were collected and analyzed five times from 14 agricultural or private wells existing in Shingwang-myeon and Heunghae-eup. As a result of the analysis, it was found that Ca2+ was the dominant cation in Shingwang-myeon, while Na+ was the dominant cation in Heunghae-eup. The elevated NO3- concentration in Shingwang-myeon is contributed to the agricultural activity in the area. A high concentration of Fe was detected in a well on Heunghae-eup; the concentration exceeded the drinking water standard by nearly 100 times. Relatively higher dissolved ions were observed in the groundwater of Heunghae-eup, and it is considered as the result of the flow velocity difference and water-rock reaction accompanying the difference in bedrock and sediment characteristics. The groundwater of Shingwang-myeon appeared to be most affected by the weathering of granite and silicates, while that of Heunghae-eup was mainly affected by the weathering of silicates and carbonate. The background concentrations (baselines) of groundwater Shingwang-myeon and Heunghae-eup was identified through the survey; however, the continuous monitoring is required to monitor the possible changes and the repeatability of seasonal variation.

Transition and prospect of quantitative indexes for integrated water management (통합물관리 정량지표의 변천과 전망)

  • Jae Sung Jung;Jin Keun Song
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.441-441
    • /
    • 2023
  • 통합물관리는 2000년 이전부터 필요성이 논의되다가 2019년 물관리기본법이 제정·시행되면서 수량, 수질, 수생태, 방재 등 분야의 물관리 통합이 단계적으로 추진되고 있다. 수자원장기종합계획, 물환경관리 기본계획, 국가물관리기본계획, 4대강별 유역물관리종합계획 등이 수립되거나 수립중에 있다. 2021년 6월에 수립된 국가물관리기본계획에서는 통합물관리 정량지표들을 물환경, 물이용, 물안전, 물산업, 거버넌스의 5개 분야로 구분하여 제시하였고, 4대강 유역물관리종합계획(안)에서는 국가기본계획의 지표들을 근간으로 유역별 특성을 고려한 정량지표를 설정하고 있다. 수자원장기종합계획부터 유역물관리종합계획까지 통합물관리 정량지표들의 변천 내용과 현황을 검토하였다. 수자원장기종합계획(2016~2020)의 전략과 목표는 "①맑은 물 공급: 급수보급율, 관망 복선화율, 댐 부족량 공급기준, 비상급수 피해인구, 스마트시티 음용률, 누수율 저감, 물 기본법 제정, ②홍수안전 기반구축: 하천기본계획, 하천정비, 수해금액, 도시하천 종합치수대책 수립, 국가하천 홍수예보 지점, 홍수예보시간 단축지점 비율, ③친수환경 조성: 하천유지유량, 하천 이용객, 어류종 및 철새종 증가, ④수자원산업 및 기술개발: 일자리, 수자원산업 육성제도, 해외수주액, 외국 MOU, 국제회의, 남북공유하천 협의"이었다. 물환경관리 기본계획(2016~2025)의 전략과 목표는 "①물순환 체계: 불투수면적률 25% 초과지역, ②깨끗한 물 확보: 상수원 수질달성, ③생태계 서비스 증진: 수생태계 건강성 달성, ④물환경 기반 조성: 산업폐수 유해물질 배출저감, 상수원 4대강 보의 총인 농도와 남조류 세포수, ⑤경제·문화적 가치 창출: 국민체감 만족도"이었다. 국가물관리기본계획에서는 "①물환경: 하천·호소 목표수질 달성률, 수생태계 건강성 B등급 이상 비율, ②물이용: 수돗물 만족률-직·간접 음용률, 노후 상수관로-하수관로 개량, ③물안전: 가뭄피해 인구, 홍수피해 인구-피해액, 댐안전성 강화율, ④물산업: 물관리 R&D 예산, 수량·수질·수생태 통합측정 중권역 비율, 물산업 매출액의 수출액 비중, 한국 주도 국제협력 의제, ⑤거버넌스: 미정"을 계획지표로 하였다. 유역종합계획에서는 4대강별로 거버넌스를 포함하여, "①물환경: 국가계획지표, 주요 상수원 수질, ②물이용: 노후 상하수관로 개량, 지방상수도 유수율, ③물안전: 한해 인구, 수해 인구-피해액, 하천정비율, ④물산업: 물산업 일자리 창출, ⑤거버넌스: 물포럼, 시민참여활동"을 정량지표로 고려하고 있다.

  • PDF

Effect of Green Tea Beverage on the Removal of Cadmium and Lead by Membrane Filtration (막투과법에 의한 녹차음료의 카드뮴 및 납 제거효과)

  • Choi, Sung-Inn;Lee, Jung-Hi;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.740-744
    • /
    • 1994
  • This study was undertaken to prove the suppressing effect of green tea on the intestinal absorption of heavy metals using in vitro membrane filtration system. From drinking water contaminated with 10 and 100 times level of water quality standard for heavy metals, the removal ratio of lead (Pb) was $50{\sim}70%$ by green and black teas, and $30{\sim}40%$ by roasted barley tea. The removal ratio of cadmium (Cd) was $30{\sim}40%$ by green tea and black teas, and $10{\sim}20%$ by roasted barley tea. The removal effect from drinking water contaminated with both lead and cadmium was lower than that from water contaminated singly with lead or cadmium. It appears that tea components and filter membrane compete toward the adsorption of two heavy metals. Among the extraction conditions of raw tea materials at $70^{\circ}C$, 2 minutes and $95^{\circ}C$ , 10 minutes, the removal ratios of heavy metals were similar.

  • PDF