• 제목/요약/키워드: 음압 레벨

검색결과 184건 처리시간 0.025초

KHST 차량 벽면의 투과손실값 예측 (Transmission Loss Prediction of KHST′s Wall)

  • Kim, Kwanju;Taejung Yoon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.317.2-317
    • /
    • 2002
  • Transmission loss of KHST passenger vehicle was calculated using measured acoustic data: In order to verify the transmission loss results for KHST case, similar experiment was carried out in laboratory condition, which result was compared those by geometric acoustic method. The computational results shows good agreement with the transmission loss magnitude from experiments. This paper also mentions items to obtain more accurate transmission loss values, i. e. how to assure reverberant field condition, the selection of source speaker' location.

  • PDF

64채널 디지털 보청기의 In-situ에 의한 휘팅 실험 연구 (An Experimental Study on the Fitting of 64 Channel Digital Hearing Aid by In-situ Method)

  • 장순석
    • 한국음향학회지
    • /
    • 제31권5호
    • /
    • pp.273-279
    • /
    • 2012
  • 본 논문에서는 64채널 디지털 보청기의 주파수 채널 별 비선형 압축을 위한 휘팅 기법을 연구하였다. 청력 검사 결과로부터 수행되는 기존의 휘팅 포뮬라 기법과 달리, 귓속형 보청기를 사용자가 외이도에 착용한 상태에서 고막에서의 청력 역치를 측정하여 이를 휘팅에 적용하였다. 또한 외부 음성 음압의 주파수 별 분포도를 활용하여 입력 음압 대비 출력 음압 압축 곡선을 구현하였다. FFT-iFFT 방식의 이론적 압축 연구 결과를 실험적으로도 검증하였으며, 입력음압 레벨이 각각 50 dB, 70 dB, 90 dB일 때의 증폭 이득 곡선을 보여주었다.

제주 연안산 잿방어의 청각특성에 관한 기초적 연구 (A Fundamental Study on the Auditory Characteristics of Amberjack Seriola dumerili in the Coast of Jeju Island)

  • 서익조;김성호;김병엽;이창헌;서두옥
    • 수산해양기술연구
    • /
    • 제39권4호
    • /
    • pp.269-275
    • /
    • 2003
  • 제주도 연안 정치망의 여름철 주 어획대상인 잿방어를 실험어로 하여, 음향을 이용한 어군행동 제어, 음향순치 등 바다목장 조성을 위한 어군의 관리, 사육, 어획기술에 이용할 기초자료를 제공할 목적으로 육상수조에서 수중 가청 저주파음과 전기충격을 이용하여 음향 학습 시킨 후, 주파수와 음압을 변화시켜가면서 잿방어의 섬전도를 도출 하여 심박간격의 변화로부터 청각문턱치, 청각임계비를 측정하였다. 자연환경소음에서 잿방어의 청각문턱치는 측정 주파수 80∼800 HZ의 수중 가청음을 모두 인식하였고, 측정 주파수 200∼500 HZ 에서 청각 감도가 양호하였으며, 측정 주파수 300 Hz에서 평균 음압 94.5 dB, 표준편차 4.5 dB로 가장 낮은 청각문턱치를 보였다. 평균 음압을 65 dB, 70 dB, 75 dB의 3단계로 변화시킨 백색잡음 방성으로 측정한 잿방어의 청각임계비는 측정 주파수 80, 100, 200, 300, 400, 500, 800 HZ에서 각각 평균 음압 45.9, 52.8, 42.5, 36.4, 38.6, 39.4, 44.4 dB이었다. 측정 주파수 300 HZ, 400 HZ 그리고 500 HZ 에서는 백색잡음 중에서 측정음을 식별하는 능력이 다른 측정 주파수에 비하여 우수했다. 잿방어가 주파수 300 HZ의 수중 가청음을 충분히 인식하기 위해서는 최저 100 dB 이상의 음압 강도가 펼요하며 환경 소음이 존재하는 환경에서는 소음 스펙트럼 음압 레벨보다 약 35 dB 이상 크게 방성할 펼요가 있다.

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(2) - 음압레벨에 의한 평가 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(2) - Estimation by Sound Pressure Level -)

  • 김철환;장태순;이기정;김동준;정태량;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1125-1128
    • /
    • 2007
  • In order to improve the acoustic performance of a noise barrier without increasing its height, various type of acoustic devices are suggested but, there is no proper method to estimate the performance in Korea. For this, an outdoor test facility was established in Expressway and Transportation Technology Institute(ETTI) of Korea Expressway Corporation for testing the acoustical performance of noise reducing devices installed on the top of a noise barrier. Noise measurements before and after installation of the noise reducing devices were carried out by using sound pressure level for long distance range from the barrier, from 10m to 40m. For considering the directivity effects of noise reducing devices, multivariate regression analysis was attempted.

  • PDF

거주자의 거동으로 발생하는 바닥진동의 층간 전달 및 바닥충격음의 음압레벨 특성 평가 (Characteristics of Transmission of Floor Vibration and Floor Impact Noise Due to Human Activities)

  • 이민정;최현기
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.5-13
    • /
    • 2017
  • Noise complaints among neighbors in apartment building are mainly caused by floor impact noise that is structure born noise due to occupant induced floor vibration. To control this noise problems many researchers have investigated floor systems and finishing materials. Light-weight impact noise affects by finishing materials, but heavy-weight impact noise induced by heel impacts during normal walking or jumping of children is concerned with structural system and floor vibration. To figure out the characteristics of floor impact noise and transmission of floor vibration due to human activities, vibration tests were conducted in apartment buildings. Impact hammer, heel drop and walking activities were loaded at center of upstairs living room, and accelerations of slabs for both upstairs and downstairs and sound pressure levels for downstairs were measured. The acceleration ratio of transmitted floor vibration to downstairs and human induced vibration in upstairs was between 0.5 and 1.0 according to slab size, wall, and load type. And floor impact noise occurred in the range of natural frequency of slab.

천장형 에어컨 소음의 허용 음압레벨 도출 (Allowable sound pressure levels of ceiling mounted air-conditioning sounds)

  • 유진;정충일;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

강의실에서의 음향특성 평가에 관한 연구 (A study of the estimation for sound property in the classroom)

  • 이채봉
    • 융합신호처리학회논문지
    • /
    • 제8권1호
    • /
    • pp.32-38
    • /
    • 2007
  • 강의실에서의 환경조건을 확립하기 위해 PA(Public-Address)를 사용한 경우와 PA를 사용하지 않은 경우의 두 가지 패턴으로 임펄스 응답을 측정하였다. 측정결과에 의해 음성 명료도에 관련된 음향물리지표를 계산하고 PA 유무에 의한 각 지표의 차이를 검토하였다. 그리고 임펄스 응답을 이용하여 4연속 음절 명료도 시험을 하여 잔향에 따른 PA사용이 어느 정도 음성 듣기를 향상시키고 있는가도 검토하였다. 그 결과, 잔향이 어느 정도 적은 경우에는 PA에 의한 음압레벨의 향상이 충분한 명료도의 개선이 되는 가능성이 있으나 잔향이 긴 경우에는 제시 음압레벨을 높여도 PA 시스템에서는 명료도의 개선이 기여되지 않는다는 것을 알 수 있었다.

  • PDF

T자형 복도 공간의 비상 방송용 확성기 배치별 음압 레벨과 음성 명료도 비교 (Comparison of Sound Pressure Level and Speech Intelligibility of Emergency Broadcasting System at T-junction Corridor Space)

  • 정정호;이성찬
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.105-112
    • /
    • 2019
  • 본 연구에서는 T자형의 복도 연결 공간에서 비상 방송음이 명료하고 고르게 전달되는지를 건축음향 시뮬레이션을 이용하여 알아보았다. 복도 공간의 흡음성능 변화, 비상 방송용 확성기의 설치 위치와 간격을 변화시켜 보았으며 변화에 따른 음압 레벨 분포, 음성 전달 지수(STI, RASTI) 분포를 비교하였다. 시뮬레이션 결과 명료한 음성 전달을 위해서는 비상 방송용 확성기를 T자형 복도 연결부의 중심에서 약 10 m를 이격시켜 설치하는 것이 좋은 것으로 나타났다. NFSC의 25 m 설치 간격을 좁히는 경우 더욱 명료하고 충분한 음량을 갖는 비상 방송음이 고르게 전달될 수 있는 것으로 나타났다.

송풍기${\cdot}$압축기의 소음레벨 측정방법 KS B 6361의 개정 (Method of A-Weighted Sound Pressure Level Measurement for Fans, Blowers and Compressors)

  • 이승배;김경호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.189-199
    • /
    • 1999
  • The revision was proposed for methods A-weighted sound pressure measurement for fans, blowers and compressors in order to apply newly developed measurement techniques to KS B 6361 established in 1987. This proposal includes modification of terminologies, revision of sound power methods for radiated sound from the body, inclusion of In-duct measurement method, and correction method for flow noise upon microphon.

  • PDF