Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

Quality Management for Mammography Equipment and Mammography (유방촬영장치와 유방검사를 위한 품질관리)

  • zheng, Hao Yang;Cho, Pyong Kon;Kim, Tae Woo;Kim, Jung Soo;Jang, Hyon Chol;Lee, Mi Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.683-692
    • /
    • 2018
  • Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.

A Study on Radiation Beam Quality Set-up of Mammography Equipment and Average Glandular Dose (유방 촬영 장치의 국제 규격 Beam Quality 기준에 따른 평균 선량 평가에 관한 연구)

  • Park, Yoon-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Mammography using X-rays is currently the most used for early diagnosis of breast cancer. As the frequency of use of X-ray devices increases, interest in radiation hazards caused by mammography is increasing. Therefore, in this study, in order to measure the exposure dose of the mammary gland in X-ray mammography that requires high contrast and high resolution, the international Atomic Energy Agency (IAEA) stipulates the international standards presented by IEC 62220-1-2: 2015. Based on the beam quality criteria of the recommendation, we tried to present a guideline for evaluating the average mammary gland dose. As a result, the average streamline dose value of the 4.5 cm PMMA phantom was 2.3 mGy at the maximum within the 30 kV range, and was evaluated to be 1.19 mGy based on 28 kV.

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

Labeling and Marking in Mammography (유방촬영에 있어서의 기호표시)

  • Woo, Wan-Hee
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2000
  • 최근에는 우리나라에서도 mammography의 중요성이 더욱 부각되고 있는데, 아마도 이전 보다 유방암 환자가 더 늘어났기 때문이 아닌가 생각된다. 미국에서는 오래전부터 mammography에 대해 체계적인 관리와 지속적인 교육이 이루어져, 오늘날에는 방사선과전문의, 방사선사, 물리학자 등의 자격기준과 유방촬영장치에 대한 기준, 그리고 patient care에 이르기까지, mammography에 대한 전반적인 기준이 마련되어 있다. 이에 반해 우리는 아직까지 이렇다할 기준이 없는 상태이나 최근에 mammography의 중요성이 논의되고, 기준 마련에 대한 노력이 이루어지고 있어 좋은 결과가 기대된다. 이러한 여러 사람들의 노력에 일조하는 마음으로 ACR(American College of Radiology)에서 권고하는 labeling과 표준화된 marking에 대하여 소개한다.

  • PDF

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

The energy spectrum and phantom image quality according to mammography target-filter combinations (유방촬영장치의 타깃에 따른 에너지스펙트럼 및 팬텀영상화질)

  • Jang, Seyoung;Oh, Wanggyun;Park, Jongbae;Jin, Gyehwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2013
  • When the X-ray energy is high, the X-ray penetrates the object and decrease the contrast of imaging, and when the X-ray energy is low, the X-ray increases the contrast of imaging but it is to be absorbed into the object, which in the long run increases patient's radiation exposure level. Therefore, appropriate X-ray energy is an essential element affecting the imaging quality and radiation exposure level. This study simulated the energy spectrums according to the target materials of mammography, and compared qualities of phantom imaging for the management of radiolographic quality and patient's radiation exposure level with the introduction of the mammography that employs diversified radiation quality by using new anode materials.