Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

A Study on the Compression paddle of meterials in Mammography (유방촬영장치에서 압박대 재질에 관한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.187-188
    • /
    • 2015
  • 유방촬영은 날로 증가추세에 있으며 압박을통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질 중 비결정 플라스틱에 대한 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

The Evaluation of Radiation Dose by Compression paddle meterials in Mammography (유방촬영장치에서 압박대 재료에 따른 피폭선량 평가)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.183-184
    • /
    • 2014
  • 유방촬영은 날로 증가추세에 있으며 압박을 통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기 위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질과 탄소계열의 카본의 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

Evaluation of Radiolucent Considering the Compression Paddle Materials in Mammography (유방촬영장치의 압박대 재질을 고려한 투과선량 평가)

  • Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.307-312
    • /
    • 2015
  • Mammography improves image quality that is on the increase day by day and get a picture with the pressure it is essential to reduce the dose. However, because due to the thickness of the cuff itself may increase the dose scattering lines is necessary study on the cuff material. Material that is currently being used in clinical Polycarbonate is a plastic and family. If you try to reduce the exposure of patients than itgie need to consider for the better material in this study to compare against a radiolucent line for amorphous plastic material of the plastic. results radiolucent and half layer, transmitting dose Pixel values HIPS, GPPS, ABS, Tritan, PC, PMMA showed high results in the net.

Analysis of Factors Related to Pain Relief on Modified Mammography (변형 유방촬영술시 통증완화에 따른 요인 분석)

  • Jang, Myung Mi;Kim, Hwa Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.413-421
    • /
    • 2017
  • Mammography, the basic test for finding and treating increased breast cancer, gives the anxiety of cancer and radiation exposure to most women. In addition, it gave very severe compression pain, so we studied the degree of pain and tried to reduce the pain. The purpose of this study is to compare and analyze the modified imaging technique and the basic imaging technique based on clinical experience, respectively. The subjects of this study were 160 women from 30 to 60 years old who visited to Seoul Boramae Hospital operated by Seoul National University Hospital from February to March 2017 for breast screening. Modified 80 persons and 80 persons were divided into two groups, and each group was asked to fill out questionnaires sequentially without knowing the subjects. The first method is a modified method in which an automatic pedal is divided into four or more presses, a manual pressure is used together, and an attitude is described in detail. Secondly, we used only the automatic pedal compression method and press it within 1-3 times. In the mean of the pain distribution, the experimental group (modified method) was 2.49 and the control group (basic method) had an average of 4.86, which showed 48.8% less pain. In this modified method, the pain scores of the experimental group were lower than those of the control group, and the degree of the pain was statistically significant.

Evaluation of Breast Dose by Breast Pressure Thickness of Breast Prosthesis Insertion (보형물 삽입 유방의 압박 두께에 따른 유방 선량 평가)

  • Lee, Hyeon-Yong;Kim, Ji-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.469-473
    • /
    • 2020
  • Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through appropriate test conditions. The significance of this study is that breast dose studies, which were limited to ordinary women, were applied to breast implant patient. Using MCNP simulation, the phantom with prosthesis inserted was developed to compare dose by tube voltage by pressure thickness. In addition phantom without prostheses has higher dose than phantom with prostheses. If these results were used as basic data, it would be possible to recommend test condition guideline only for breast implant patients.

Patient Dose in Mammography (유방촬영에서 환자 피폭선량)

  • Shin, Gwi-Soon;Kim, You-Hyun;Kim, Jung-Min;Kim, Chang-Kyun;Yang, Jeong-Hwa;Choi, Jong-Hak
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.293-299
    • /
    • 2005
  • In the present investigation, we analyzed the data of 1,318 patients (2,636 images) who underwent mammographic examinations and obtained the distribution of the patient age and compressed breast thickness. We measured also average glandular doses (AGD) as function of compressed breast thickness. In order to obtain the values of AGD, we measured half value layer (HVL) and tube output (mR/mAs) for each kVp and target/filter combination. Entrance surface air kerma (ESAK) was calculated from the tube output as measured for each voltage used under clinical conditions and from the tube loading (mAs). AGD per exposure were calculated by multiplying the ESAK values by the conversion factors tabulated by Dance. We obtained in this study the following conclusions. The mean value of compressed breast thickness for cranio-caudal (CC) view was 35.8mm and that for medio-lateral oblique (MLO) view was 43.3 mm. The mean value of AGD for CC view was 1.55 mGy and that for MLO view was 1.70 mGy. The AGD for MLO view was 0.15 mGy (10%) higher than that for CC view because the thickness for MLO view was on average 4.8 mm higher than that for CC view. The values of AGD increased with increasing compressed brest thickness. The increased AGD value was on average 0.34 mGy per 10 mm in the thickness ranges $10{\sim}80\;mm$, therefore differences between the AGD values of each thickness were relative large. Thus, it is considered to need limited doses for mammography with the upper end of exposure range at several different compressed brest thickness.

  • PDF

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.

A Study on Development of Mammo Pad and Analysis of Factors Affecting Compression Pain for Mammography (유방 방사선 검사를 위한 압박 패드의 제작 및 유방 압박 통증에 영향을 주는 요인 분석)

  • Kim, Do-Hee;Yi, Ann;Kwon, Bo-Ra;Ku, Hong-Uk;Bang, Yong-Sik;Cho, Myeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.629-636
    • /
    • 2021
  • The purpose of this study was to identify the effects of mammo pad made of different kinds of materials on the reduced inconvenience and compression pains of patients to examine plausible interchangeability of existing pads made of single kind of material, and to examine the changes in pains of patients taking mammography and various factors therein. The high-hardness and highly-elastic mammo pressure pads, capable of replacing existing mammo pad of "H" company, were manufactured, and the display quality of mammography obtained from respective mammo pad were compared to each other to appraise the availability of manufactured mammo pad. In addition, 200 patients, who came to a general hospital in Seoul, were selected as subjects for the survey employing a questionnaire which was distributed to the subjects from December 2018 to March 2020 to identify the factors involved with the mammo pad of patients while taking mammography. The results of mammography obtained from both of the existing and newly manufactured mammo pad revealed appropriate display qualities fell within the range of clinical criteria. Besides, the factors associated with changing compression pains of patients taking mammography were analyzed wherefrom the general factors in the following order of age, height, and BMI index appeared, while the experiential and female factors appeared as in the following order: presence of menstruation, experience of child-birth, experience of breast feeding, menopause, grade of breast, shape of breast, and experience of mammography. In conclusion, the following factors comprising the age, experience of breast feeding, experience of mammography, and menopause rendered approximately 54% of power of explaining the degree of changing pains during mammography. Regarding the changes in compression pains while taking mammography, the increasing experience of mammography of patients rendered approximately 0.26 times more at the intermediate range of compression pains and approximately 0.14 times more at the range of severe pains.