• Title/Summary/Keyword: 유방촬영

Search Result 248, Processing Time 0.025 seconds

Measurement of the Compression Force and Thickness applied during Mammography (유방촬영술에서 압력과 두께 측정)

  • Kweon, Dae-Cheol;Lee, Eun-Mi;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.29-35
    • /
    • 2003
  • The purpose of this study was to compare the compression force and thickness of the compressed breast between mediolateral oblique and craniocaudal mammography. This population consisted of 204 paired mediolateral oblique and craniocaudal mammography obtained on one mammographic unit by certified mammography technologists during 2 month period. The women examined were $30{\sim}59$ years old with breast implants, the patients were classified into 3 groups according to age, $30{\sim}39$, $40{\sim}49$, and $50{\sim}59$, prior breast cancer, mastectomy or breast deformity were excluded. The digital readout of compressed breast compression force and thickness was recorded. Mammographic positioning was assessed using standard criteria. The mean compression force of the compressed breast on the craniocaudal projection was less than the mean compression force on the mediolateral projection(14 versus 13.88 daN, p<0.05). The mean thickness of the compressed breast for mediolateral projection was 41.46 mm and that for the craniocaudal projection was 39.50 mm(p<0.05). The compressed breast is higher or thicker on mediolateral oblique than on craniocaudal mammography.

  • PDF

Micrometer Spatial Resolution Imaging System Using Synchrotron X-ray (Synchrotron X-선을 이용한 Micrometer 공간 분해능 영상시스템)

  • 홍진오;정해조;정하규;제정호;김은경;유형식;김희중
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.165-169
    • /
    • 2001
  • 최근 포항 방사광 가속기 연구소에 미세구조 X-선 영상 실험을 위한 5C1 방사광(Synchrtoron Radiation) 빔라인이 건설되었다. 광대역의 에너지 스펙트럼을 가진 방사광 X-선이 물체를 투과한 후 CdWO$_{4}$ scintillator에 의해 가시광선으로 바뀌고, 그 빛을 CCD 카메라로 받아들여 영상을 획득하게 된다. 방사광 X-선은 일반 의료진단용 X-선에 비하여 위상이 일치하고, 평행하며, 그 양이 풍부한 특성들을 갖고 있다. 방사광 영상시스템과 X-선 유방촬영 시스템에서 영상을 획득하여 영상특성들을 비교, 분석하였다. 고-분해능 X-선 시험 패턴(20 line pairs mm$^{-1}$), 유방촬영 팬텀, 파라핀에 고정한 인체 유방암조직과 포르말린에 고정한 인체 유방암조직, 그리고 capillary tube내 micro-bubbles등의 방사광 영상은 기존의 X-선 유방촬영시스템에서 얻은 영상보다 분해능이 뛰어나고 영상질도 우수하였다. 방사광 X-선 영상시스템은 micrometer 공간 분해능 영상을 획득할 수 있어 많은 기초분야의 영상연구와 의료영상분야에서도 활발하게 활용될 것으로 기대된다.

  • PDF

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Analysis of Radiation Protection, Awareness and Attitude of Radiological Technologist in Mammography Room (유방촬영실에 근무하는 방사선사의 방사선 방어, 인식 및 태도에 관한 분석)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.557-565
    • /
    • 2017
  • This study was conducted to investigate the radiation protection, awareness, and attitude of radiological technologists in the mammography room due to the low energy use of breast imaging. Data collection was performed by 222 independent radiological technologists in the breast and breast clinic of six hospitals except Jeju Island. The independent sample t-test and oneway variance analysis were performed. As a result, it was found that the lower the number of men(p<0.05), the age of 30s(p<0.05), the marriage(p<0.05), the work experience of more than 10 years(p<0.05), the working hours of 8 hours(p<0.01), the less the impact of radiation(p<0.01), the more important it was to radiation defense. appear. This is thought to be influenced by the work specificity and work environment of the mammography room, and it will be used as a basic data to raise awareness and act on the exposure through analysis with other factors.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Quality Management for Mammography Equipment and Mammography (유방촬영장치와 유방검사를 위한 품질관리)

  • zheng, Hao Yang;Cho, Pyong Kon;Kim, Tae Woo;Kim, Jung Soo;Jang, Hyon Chol;Lee, Mi Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.683-692
    • /
    • 2018
  • Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.

Material Decomposition through Weighted Image Subtraction in Dual-energy Spectral Mammography with an Energy-resolved Photon-counting Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 광자계수검출기 기반 이중에너지 스펙트럼 유방촬영에서 가중 영상 감산법을 통한 물질분리)

  • Eom, Jisoo;Kang, Sooncheol;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.443-451
    • /
    • 2017
  • Mammography is commonly used for screening early breast cancer. However, mammographic images, which depend on the physical properties of breast components, are limited to provide information about whether a lesion is malignant or benign. Although a dual-energy subtraction technique decomposes a certain material from a mixture, it increases radiation dose and degrades the accuracy of material decomposition. In this study, we simulated a breast phantom using attenuation characteristics, and we proposed a technique to enable the accurate material decomposition by applying weighting factors for the dual-energy mammography based on a photon-counting detector using a Monte Carlo simulation tool. We also evaluated the contrast and noise of simulated breast images for validating the proposed technique. As a result, the contrast for a malignant tumor in the dual-energy weighted subtraction technique was 0.98 and 1.06 times similar than those in the general mammography and dual-energy subtraction techniques, respectively. However the contrast between malignant and benign tumors dramatically increased 13.54 times due to the low contrast of a benign tumor. Therefore, the proposed technique can increase the material decomposition accuracy for malignant tumor and improve the diagnostic accuracy of mammography.

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

Scintigraphic Detection of Small Breast Carcinomas (핵의학 유방영상법을 이용한 작은 유방암 진단)

  • Park, Chan-H.;Gonsalves Carin;Rosenberg Ann;Rosato Francis;Feig Stephen A.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.459-463
    • /
    • 1997
  • 핵의학적 유방영상법은 오랜동안 시범되어 왔지만 임상에서 큰 역할을 못했고, 근래에 핵의약품과 핵의학기기 사용방법의 발전으로 scintimammogram(SM)이 다시 각광을 받게 되었다. 유방암 진단에 대한 핵의학영상법의 특이도와 예민도가 방사선 유방촬영법보다 높다고 보고되었으나 1cm보다 작은 유방암은 SM에 용이하게 발견되지 않는다. 본 보고에서는 1cm보다 작은 유방암이 발견된 두 증례를 발표한다. 한증례는 $^{99m}Tc$ MDP를 수술전 골영상을 위해서 사용하였고, 두 번째 증례는 비촉지 유방종괴를 $^{99m}Tc$ MIBI로 유방촬영 하였다.

  • PDF

Labeling and Marking in Mammography (유방촬영에 있어서의 기호표시)

  • Woo, Wan-Hee
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2000
  • 최근에는 우리나라에서도 mammography의 중요성이 더욱 부각되고 있는데, 아마도 이전 보다 유방암 환자가 더 늘어났기 때문이 아닌가 생각된다. 미국에서는 오래전부터 mammography에 대해 체계적인 관리와 지속적인 교육이 이루어져, 오늘날에는 방사선과전문의, 방사선사, 물리학자 등의 자격기준과 유방촬영장치에 대한 기준, 그리고 patient care에 이르기까지, mammography에 대한 전반적인 기준이 마련되어 있다. 이에 반해 우리는 아직까지 이렇다할 기준이 없는 상태이나 최근에 mammography의 중요성이 논의되고, 기준 마련에 대한 노력이 이루어지고 있어 좋은 결과가 기대된다. 이러한 여러 사람들의 노력에 일조하는 마음으로 ACR(American College of Radiology)에서 권고하는 labeling과 표준화된 marking에 대하여 소개한다.

  • PDF