• Title/Summary/Keyword: 유방보형물

Search Result 13, Processing Time 0.024 seconds

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Understanding Silicone Breast Implant-Associated Complications for Radiologists (영상의학과 의사들을 위한 실리콘 유방 보형물 관련 합병증의 이해)

  • Jeongmin Lee;Sung Hun Kim;Jae Hee Lee;Boo Kyung Han
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.49-65
    • /
    • 2021
  • With the increase in the number of cases of silicone implant insertion either for cosmetic surgery or breast reconstruction after mastectomy, it is not unusual to encounter patients with silicone implants in clinical settings. Recently, the first case of breast implant-associated anaplastic large cell lymphoma was reported in Korea. In addition to previously known complications, such as implant rupture or contracture, the number of implant-associated imaging examinations has also increased. Considering this background, radiologists should have sufficient knowledge about the type of examination required in patients who have undergone implant insertion and imaging findings to correctly identify implant-associated complications. In this article, various complications of silicone implants are discussed, including various imaging findings, which radiologists should know.

Postpartum Galactocele in Augmented Breast after Using Breast Pump Mimicking Breast Implant-Associated Anaplastic Large Cell Lymphoma: A Case Report (유방확대술 받은 수유 중인 여성에서 유축기를 사용한 뒤 발생한 유방 보형물 관련 역형성 거대 세포 림프종 모방 산후 젖낭종: 증례 보고)

  • Ga Young Lee;Gi Won Shin;Young Mi Park;Anbok Lee;Ha Young Park;Yoo Jin Lee;Ji-Yeon Han
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1570-1574
    • /
    • 2021
  • Post-partum galactocele is a common benign disease among breastfeeding women, whereas retromammary and peri-implant galactocele are relatively rare conditions. Herein, a 34-year-old, 1 month-postpartum female, who had augmentation mammoplasty and a 1-month history of breast pump use, presented with left breast enlargement for 2 weeks. An initial left breast US revealed hyperechoic peri-implant fluid collection. Additional US-guided fine needle aspiration was done using a 21G-needle, draining the milk component in the process, and cytologic results revealed numerous crystals, suggestive of galactocele. Various diseases, especially breast implant-associated anaplastic large cell lymphoma, can cause peri-implant fluid collection in an augmented breast. Thus, correlating imaging features with clinical information and cytologic analysis plays an important role in appropriate management.

Evaluation of Breast Dose by Breast Pressure Thickness of Breast Prosthesis Insertion (보형물 삽입 유방의 압박 두께에 따른 유방 선량 평가)

  • Lee, Hyeon-Yong;Kim, Ji-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.469-473
    • /
    • 2020
  • Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through appropriate test conditions. The significance of this study is that breast dose studies, which were limited to ordinary women, were applied to breast implant patient. Using MCNP simulation, the phantom with prosthesis inserted was developed to compare dose by tube voltage by pressure thickness. In addition phantom without prostheses has higher dose than phantom with prostheses. If these results were used as basic data, it would be possible to recommend test condition guideline only for breast implant patients.

Evaluation of Breast Dose in Mammography for Breast Implant Patient using a Monte Carlo Simulation (몬테칼로 모의모사를 이용한 유방성형술 환자의 유방선량평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.253-259
    • /
    • 2020
  • Mammography has the advantage of being economical, simple and effective in detecting microcalcification, but breast is a highly sensitive organ and is accompanied by the risk of an over-exposure. While accurate dose assessments are important to prevent this, current breast dose assessments are limited to breast implant patients. This purpose of this study was to identify dose variations due to tube voltages by forming a mock-up with breast implants for an accurate dosimetric assessment on breast implant patients. As a result, doses from the presence of breast implants were smaller than those from the absence of the mammal. As the result of the change of the voltage to 26, 28, 30, and 32 kV, the imcreased tube voltage included larger dose regardless of the presence of Breast implant. Therefore, it is believed that diagnosis recommendations for breast implants will be possible if further studies on internal and external bioretical imaging and quality assessment are carried out as the basis for this study.

Simultaneous Nuss Operation and Mammoplasty in an Adult Patient with Pectus Excavatum - A case report - (성인 여자 오목가슴 환자에서 유방 확대술과 동시에 시행한 너스 수술 - 1예 보고 -)

  • Kim, Kyung-Soo;Cho, Deog-Gon;Cho, Kyu-Do;Jo, Min-Seop;Kang, Chul-Ung
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.523-526
    • /
    • 2008
  • Minimally Invasive repair of pectus excavatum using a metal bar, as advocated by Nuss, has been broadly accepted recently for its aesthetic aspect. There are and various treatment methods, as welt. Pectus excavatum may be accompaniedso many modified repair methods have been developed and performed. We report a case of a 33-year-old woman with pectus excavatum and breast hypoplasia, which were simultaneously corrected using a substernal steel bar and mammoplasty.

A Study on Effect of the Image Applying to Breast Implants in Breast Specific Gamma Imaging (유방전용감마카메라에서 유방 보형물이 영상에 미치는 영향에 관한 고찰)

  • Lee, Juyoung;Lee, Tae Soo;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.33-38
    • /
    • 2018
  • There are limits to check the lesion as inserting a breast implant patients. So the application of BSGI based on Nuclear Medicine examination has increased. In this study, therefore we confirmed the effect of the image applying to breast implants in Breast Specific Gamma Imaging. We utilized Dilon 6800 BSGI scanner and developed the phantom. The self-development phantom was a rectangular shape of $230{\times}190{\times}80mm$ size and had 5 spheres which consisted of diameters of 10, 13, 17, 22, 28 mm in central part. We injected $^{99m}TcO_4$ into the self-development phantom in the proportion of four to one and made each additional phantom filled with 0.9 % sodium chloride, silicon and paraffin. Each additional phantom was placed between detector and self-development phantom. Each image was acquired five times depending on the type and thickness of the additional phantom. Statistical analysis with SPSS ver.18 was applied. In the test of variation according to the thickness of all additional phantoms, as the phantoms which 0.9% sodium chloride, silicon and paraffin increased, the attenuation variation was higher(P<0.005). There was no significant difference in the attenuation variation and the quality of image for type of the additional phantom. Therefore, if the effect of the image applying to breast implants in Breast Specific Gamma Imaging is confirmed, the higher diagnostic value can be achieved.

Immediate Breast Reconstruction Placing the Breast Implant under the Pectoralis Major-Serratus Anterior Pocket without Tissue Expansion (조직확장술을 거치지 않고 유방보형물을 대흉근-전거근 포켓에 삽입한 즉시 유방재건술)

  • Kim, Hoon;Eom, Jin Sub;Ahn, Sei Hyun;Son, Byung Ho;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.622-627
    • /
    • 2007
  • Purpose: Although the autogenous tissue transfer has been the mainstay of the breast reconstruction, concern for the donor site morbidity can lead to the superseded method using tissue expander with implant or permanent expander-implant. However, the additional procedure of tissue expansion possibly cause discomfort and raise the cost. We tried to verify the efficacy of using the saline-filled breast implant by itself for the safe and convenient immediate breast reconstruction modality if the patients have small, round and non-ptotic breasts and the sufficient breast skin can be saved with mastectomy. Methods: From July 2002 to July 2005, 29 breasts of 26 patients were restored only with the saline-filled breast implant immediately after the skin sparing or nipple-areolar skin sparing mastectomy in Asan Medical Center. A pocket with pectoralis major and serratus anterior muscle was created and the implant was covered with this muscle pocket. Simultaneous contralateral augmentation was performed in patients whose mastectomy specimen weighed less than 100g. Results: Using only the saline-filled breast implant resulted in the successful reconstruction with few complications including partial necrosis of nipple areolar skin (five cases, 17.2%), capsular contracture (three cases, 10.3%), hematoma (one case, 3.4%), depigmentation of areolar skin (one case, 3.4%), hypertrophic scar (one case, 3.4%), which were all healed by conservative management. There were no significant complications such as implant exposure and subsequent removal. Conclusion: Immediate breast reconstruction only with the saline-filled breast implant can be a satisfactory alternative option for the patients whose breast is small, round and non-ptotic, especially when the nipple-areolar skin of the breast is preserved in the mastectomy.

Predicting the Degree of Breast Size in Augmentation with Cohesive Gel Implant (코헤시브 실리콘 젤 보형물을 이용한 유방확대술시 보형물 크기에 따른 유방 크기 변화 예측)

  • Lee, Jung-Ho;Seo, Je-Won;Lee, Paik-Kwon;Oh, Deuk-Young;Rhie, Jong-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.256-258
    • /
    • 2010
  • Purpose: Predicting the change in breast size for a specific patient's need is a challenging problem in breast augmentation. We intended to investigate the postaugmentation degree of breast size according to the size of cohesive silicone gel implant. Methods: To predict post-augmentation breast size, we measured 100 patients' pre-and postoperative 3 month's bust circumference. All patients were performed by total subfascial breast augmentation with moderate profile cohesive silicone gel implant through areolar omega (transareolar-perinipple) incision. Results: According to this study, each additional one pair of 100 mL in implant size yielded an approximate 1.5 cm increase in bust circumference (p=0.006). Conclusion: From this result, we conclude that each additional one pair of 100 mL in implant volume yielded about 1.5 cm increase in bust circumference. Although this result may not be applied to every patient, we believe that it yields a practical chart that can help to predict the amount of increase in breast size with the use of cohesive silicone gel implant of a specific size preoperatively.

Algorithm for Fabricating 3D Breast Implants by Using MRI and 3D Scan Data (MRI와 3D 스캔 데이터를 이용한 3D 프린팅 유방 인공보형물의 제작 알고리즘)

  • Jeong, Young Jin;Choi, Dong Hun;Kim, Ku-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1385-1395
    • /
    • 2019
  • In this paper, we propose a method to fabricate a patient-specific breast implant using MRI images and 3D scan data. Existing breast implants for breast reconstruction surgery are primarily fabricated products for shaping, and among the limited types of implants, products similar to the patient's breast have been used. In fact, the larger the difference between the shape of the breast and the implant, the more frequent the postoperative side effects and the lower the satisfaction. Previous researches on the fabrication of patient-specific breast implants have used limited information based on only MRI images or on only 3D scan data. In this paper, we propose an algorithm for the fabrication of patient-specific breast implants that combines MRI images with 3D scan data, considering anatomical suitability for external shape, volume, and pectoral muscle. Experimental results show that we can produce precise breast implants using the proposed algorithm.