• Title/Summary/Keyword: 유동 계수

Search Result 1,313, Processing Time 0.026 seconds

Explicit Design of Commercial Pipe on a Slope with Pumping Power (동력경사 상용관의 양해법 설계)

  • Yu, Dong-Hun;Gang, Chan-Su
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.5
    • /
    • pp.495-501
    • /
    • 1997
  • Pumping power being given, traditional method requires an iteration process for the solution of discharge and pipe diameter. Yoo and Kang (1996) have developed explicit equations for the estimation of discharge and pipe diameter for the cases of uniformly rough pipe on a sloping bed with a pumping power. The use of poser law for the estimation of friction factor enabled to develop the explicit form of equations. Yoo (1995a) has suggested the mean friction factor method for the estimation of friction factor of commercial pipe or composite surface pipe. With the same approach, the present work has developed the explicit equations of discharge or pipe diameter for the general case of commercial pipe on a sloping bed with a pumping power by adopting the mean friction factor method.

  • PDF

Application of Artificial Neural Network to Predict Aerodynamic Coefficients of the Nose Section of the Missiles (인공신경망 기반의 유도탄 노즈 공력계수 예측 연구)

  • Lee, Jeongyong;Lee, Bok Jik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.11
    • /
    • pp.901-907
    • /
    • 2021
  • The present study introduces an artificial neural network (ANN) that can predict the missile aerodynamic coefficients for various missile nose shapes and flow conditions such as Mach number and angle of attack. A semi-empirical missile aerodynamics code is utilized to generate a dataset comprised of the geometric description of the nose section of the missiles, flow conditions, and aerodynamic coefficients. Data normalization is performed during the data preprocessing step to improve the performance of the ANN. Dropout is used during the training phase to prevent overfitting. For the missile nose shape and flow conditions not included in the training dataset, the aerodynamic coefficients are predicted through ANN to verify the performance of the ANN. The result shows that not only the ANN predictions are very similar to the aerodynamic coefficients produced by the semi-empirical missile aerodynamics code, but also ANN can predict missile aerodynamic coefficients for the untrained nose section of the missile and flow conditions.

Cavitating Flow in an Impinging-type Injector (충돌형 분사기 내의 캐비테이션 유동)

  • Jo, Won Guk;Ryu, Cheol Seong;Lee, Dae Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.80-86
    • /
    • 2003
  • An anaysis on the discharge performance of an impinging-type injector for cavitating flow has been conducted by both numerical and experimental method. The predicted discharge coefficient for cavitating flow agrees well with the measured data showing less than 1% discrepancy. For the case of non-cavitating flow analysis, the disagreement between CFD results and the experimental data is 8%. The discharge coefficient for the cavitating flow decreases with decrease in the Reynolds number. On the other hand, it increases slightly as the Reynolds number increases for the non-cavitating flow because of the reduced viscous effect. From the present study, it is confirmed that the fact that cavitation phenomena should be included to predict accurately the discharge performance of injectors for cavitating flow regime. The uniformity of density and velocity magnitude degraded at the injector exit, and the secondary flow strength through the injector orifice accentuated due to cavitation.

Numerical Study About Flow Control Using Blending Gurney Flap with Jet Flap (Gurney플랩과 제트 플랩을 혼용한 유동제어 기법에 관한 수치적 연구)

  • Choi, Sung-Yoon;Kwon, Oh-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.7
    • /
    • pp.565-574
    • /
    • 2007
  • The flow control effect of blending Gurney flap with jet flap for flow around an NACA 0012 airfoil was numerically investigated through parameter variation of each flow control mechanism on unstructured meshes. The aerodynamic force and moment variations due to flow control were examined, and the results were compared between the blending control and each individual flow control. The results showed that the blending control required less energy input to achieve the same level of lift increment than that of the jet flap, and at the same time alleviated drag increment caused by introducing the Gurney flap.

Hydrodynamic Study in the Cold CFB Reactor with 3-Cyclones (3개의 사이클론 갖는 순환유동층에서의 수력학적 특성 연구)

  • 이종민;김재성;김종진
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.57-60
    • /
    • 1999
  • 순환유동층 보일러는 연소로 (상승관: riser)내에 공기를 고속으로 주입하여 비말동반되는 고체입자를 사이클론에서 포집 하여 재주입하는 유동층을 이르는 것으로, 난류유동층(turbulent fluidized bed), 고속유동층(fast fluidized bed) 그리고 희박상 유동(dilute phase flow) 영역에서 조업이 이루어진다. 순환유동층은 비교적 높은 기체 유속에서 조업이 이루어지기 때문에 고체입자의 혼합 및 비산 그리고 재순환이 격렬하게 이루어지고, 기-고체간 접촉효율 및 전열계수가 높아 전체적인 처리량 및 효율이 좋은 장점을 가지고 있다.(중략)

  • PDF

Heat Transfer Measurement in a Supersonic Flowfield by an Infra-red Thermography (적외선 측정 기법을 이용한 초음속 유동내 열전달 측정)

  • Yu, Man-Sun;Yi, Jong-Ju;Song, Ji-Woon;Cho, Hyung-Hee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.359-362
    • /
    • 2006
  • Infra-red thermography was conducted to understand a heat transfer characteristic on a surface protruded to a supersonic flowfield. Surface temperature distribution was obtained under the constant heat flux condition with a infra-red camera and the convective heat transfer coefficient distribution was calculated. Finally, two dimensional distribution of heat transfer coefficient on a surface around a cylinder body was derived.

  • PDF

A CFD Analysis on the Gas-Liquid Ejector (가스-액체 이젝터에 대한 CFD 해석)

  • Jeong, H.M.;Utomo, Tony;Jin, Z.H.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.28-34
    • /
    • 2008
  • 가스-액체 이젝터에 관한 수치해석은 3차원 CFD 모델로 수행하였다. 본 논문에서는 이젝터의 유동특성과 질량전달특성에 대한 작동조건과 이젝터의 기하학적 모형의 영향에 관한 연구를 수행하고자 한다. CFD 결과 실험 데이터에 의하여 검증되었으며, 유동 분석과 이젝터 성능의 예측 또한 실행되었다. 작동상태의 변화는 0.2 $\sim$ 1.2 범위에서 가스-액체 유량비를 변화시킴으로서 주어진다. 혼합관의 $L_M/D_M$이 4 $\sim$ 10의 범위에서 변화를 주었다. CFD 연구는 길이와 직경비가 5.5일 때 체적 유량전달계수는 가스 유량이 증가함에 따라 증가한다는 것을 나타낸다. 동시에 $L_M/D_M$가 4일 때 체적유량전달계수는 기체-액체 유량비가 0.6에서 최대치에 도달한다. 또한, 체적 유량전달계수는 혼합 튜브길이가 증가함에 따라 감소한다.

  • PDF

A numerical study of supersonic flow characteristics around biplane airfoil (Supersonic biplane airfoil의 유동 특성에 대한 수치 해석적 연구)

  • Park, Jang-Ho
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.365-370
    • /
    • 2013
  • 현대에 이르러 초음속 운영 영역에서의 항공기에 대한 많은 연구가 진행되고 있으나, 음속 폭음 현상과 충격파 현상에서 야기된 높은 항력 및 연료 효율성 저하로 인하여 그 한계에 부딪치고 있다. Busemann 복엽 익형은 이와 같은 문제를 해결하기 위한 형상이며, 상하 형상에 의한 파동 상쇄효과 및 파동 감소효과를 통해 충격파의 강도와 음속 폭음 효과를 감소시키는 형상이다. 하지만 본 익형은 탈설계 조건에서 항력 계수가 급격하게 증가하는 등의 문제점을 가지고 있다. 본 연구에서는 EDISON_CFD를 이용하여 Busemann 복엽 익형의 주변 유동 특성에 대하여 면밀한 고찰을 수행하였다. 우선 Busemann 복엽 익형의 초기 형상에 대한 유동 조건별 해석을 통하여 탈설계 조건에서의 항력 성능 저하 문제에 대한 고찰을 하였다. 이후 3개의 형상 변수에 대한 매개 변수 연구를 통하여 익형의 각 형상 변수가 탈설계 영역 및 해당 영역에서의 최대 항력 계수에 미치는 영향에 대한 고찰을 수행하였으며, 이를 통하여 기존 형상보다 좁은 탈설계 구간을 가지고, 최대 항력 계수가 약 34.8% 감소한 부스만 복엽 익형을 설계하였다.

  • PDF

A Basic Study of Roughness coefficient of Domestic Rivers (국내 하천 조도계수 산정을 위한 기초연구)

  • Yoo, Dong-Hoon;Lee, Tae-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1775-1780
    • /
    • 2009
  • 개수로 마찰흐름 특성에 관한 연구로서 유량조사사업단(2006)의 우리나라 3대강 유역 하천 관측자료와 Jarrett(1984)의 미국 Colorado지역 하천의 관측자료로 부터 흐름특성을 구분하여 개수로 흐름의 마찰특성 또는 조도계수의 변이특성을 분석하였다. 기존 지수형 완난류 마찰계수 산정식(유동훈과 이민호,1997)의 비례상수 $\alpha$에 조도계수 n을 도입하여 실무에서 보다 편하게 적용할 수 있는 새로운 산정식을 개발하였다. 유량조사사업단의 관측자료 분석에 있어서 유량 관측시 관측지점의 수면경사 및 하상경사의 미관측으로 하천정비기본계획상에 제시된 지형으로부터 관측지점의 하상경사를 추정하였으며 1차적으로 에너지경사는 하상경사와 동일하다고 가정하였다. 이러한 가정하에 하천정비기본계획상에 제시된 Manning의 조도계수를 인용하여 관측유속과 계산유속을 비교8 분석하였다. 또한 전통적 산정식인 Ganguillet & Kutter(1869)식과 Manning(1889)식으로 부터 산정된 유속과의 비교를 통하여 조도계수 n을 추정하였고 추정된n을 도입하여 새로 개발된 지수형 마찰계수 산정식의 적용성을 입증하였을 뿐만 아니라 기존 조도계수 산정의 문제점을 제시하였다.

  • PDF

Study of Pool Boiling Heat Transfer on Various Surfaces with Variation of Flow Velocity (다양한 표면에서 유동 속도에 따른 풀 비등 열전달에 관한 연구)

  • Kang, Dong-Gyu;Lee, Yohan;Seo, Hoon;Jung, Dongsoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.343-352
    • /
    • 2013
  • In this study, a smooth flat surface, low fin, Turbo-B, and Thermoexcel-E surfaces are used to examine the effect of the flow velocity on the pool boiling heat transfer coefficients (HTCs) and critical heat fluxes (CHFs). HTCs and CHFs are measured on a smooth square heater of $9.53{\times}9.53mm^2$ at $60^{\circ}C$ in a pool of pure water at various fluid velocities of 0, 0.1, 0.15, and 0.2 m/s. Test results show that for all surfaces, CHFs obtained with flow are higher than those obtained without flow. CHFs of the low fin surface are higher than those of the Turbo-B and Thermoexcel-E surfaces due largely to the increase in surface area and sufficient fin spaces for the easy removal of bubbles. CHFs of the low fin surface show even 5 times higher CHFs as compared to the plain surface. On the other hand, both Turbo-B and Thermoexcel-E surfaces do not show satisfactory results because their pore sizes are too small and water bubbles easily cover them. At low heat fluxes of less than $50kW/m^2$, HTCs increase as the flow velocity increases for all surfaces. In conclusion, a low fin geometry is good for application to steam generators in nuclear power plants.