• Title/Summary/Keyword: 유동안정성 확보

Search Result 82, Processing Time 0.027 seconds

A Study on the Development and Performance Test of Supersonic Wind Tunnel for Education (교육용 초음속 풍동 개발 및 성능검증에 관한 연구)

  • Lee, Jin-Ho;Huh, Choul-Jun;Bae, Ki-Joon;Bae, Yung-Woo;Byun, Yung-Hwan;Lee, Jae-Woo;Chang, Jo-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.129-137
    • /
    • 2004
  • A small size - low priced supersonic wind tunnel of which test section size is 30mm by 35.6mm and run time is 20sec is developed. This educational supersonic wind tunnel is an intermittent blowdown type with an exchangeable nozzle block. In this study, the proper sized and low priced commercial parts are used to reduce the total cost of supersonic wind tunnel. A nozzle design and small supersonic wind tunnel design process has been established, and it is confirmed that a given supersonic flow field has been obtained and proved by experiment.

Numerical Technique to Analyze the Flow Characteristics of a Propeller Using Immersed Boundary Lattice Boltzmann Method (가상경계 격자볼쯔만법을 이용한 프로펠러의 유동특성해석 방법에 관한 연구)

  • Kim, Hyung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.441-448
    • /
    • 2016
  • The thrust force created by a propeller depends on the incoming flow velocity and the rotational velocity of the propeller. The performance of the propeller can be described by dimensionless variables, advanced ratio, thrust coefficient, and power coefficient. This study included the application of the immersed boundary lattice Boltzmann method (IBLBM) with the stereo lithography (STL) file of the rotating object for performance analysis. The immersed boundary method included the addition of the external force term to the LB equation defined by the velocity difference between the lattice points of the propeller and the grid points in the domain. The flow by rotating a 4-blade propeller was simulated with various Reynolds numbers (Re) (including 100, 500 and 1000), with advanced ratios in the range of 0.2~1.4 to verify the suggested method. The typical tendency of the thrust efficiency of the propeller was obtained from the simulation results of different advanced ratios. It was also necessary to keep the maximum mesh size ratio of the propeller surface to a grid size below 3. Additionally, a sufficient length of the downstream region in the domain was maintained to ensure the numerical stability of the higher Re and advanced ratio flow.

Heat Transfer Characteristics of 0.5 t/h Class Non-Furnace Boiler with a Metal Fiber Burner (금속섬유 버너를 채택한 0.5 t/h 급 무연소실 보일러의 열전달 특성)

  • Ahn, Joon;Kim, Jong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.215-220
    • /
    • 2011
  • A 0.5 t/h class non-furnace boiler has been developed with the aim of achieving a high efficiency and compactness. A metal fiber burner has been adopted so that a stable flame can be obtained. The tube banks are installed downstream of the burner. Bare tubes are used upstream, while finned tubes are installed downstream. The heat-transfer characteristics of the non-furnace boiler have been studies on the basis of the results of the numerical simulation as well as those of the experiment. Important design parameters such as the bulk temperature along the streamwise direction and the temperature of the fin tips have been evaluated using the CFD results and compared with the experimental data and the empirical correlations typically used for the design of the boiler.

Temperature performance improvement of SMPS using thermal simulation (열 해석을 이용한 SMPS 온도 특성 개선)

  • Na, Tae-Kwon;Jung, Jee-Hoon;Choo, Jong-Yang;Kwon, Joong-Gi
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.183-185
    • /
    • 2008
  • 재택근무와 소규모 창업 등 사무 환경의 변화 에 따라 프린터와 복합기의 소형화가 요구 되고 있다. 이러한 소형화에 의해 프린터 내부의 발열 요소들이 제한 된 공간에 배치되어, 기기 내부의 열 유동 및 발열 개선은 제품의 수명과 안정성 확보를 위한 중요 사항이 되었다. 본 논문에서는 프린터와 복합기의 내부 요소 중 주요 발열원인 전원 공급 장치에 대하여 Computational fluid dynamics (CFD) software 인 ICEPAK을 이용하여 중요 부품의 배치 조건에 따른 대류 와 온도 특성을 확인 하고, 최적화 된 부품 배치 방법을 제안한다. 또한 제안하는 부품 배치 방법을 적용한 초박형 프린터용 50W 급 전원 공급 장치를 제작하여 실제 온도 특성이 개선됨을 확인한다.

  • PDF

Kinematic Analysis of Samdan Didimsae Movement for Jajinmori Jangdan (자진모리장단에 따른 한국무용3단 디딤새 동작에 관한 운동학적 분석)

  • Ahn, Wan-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.203-212
    • /
    • 2008
  • The purpose of this study is to propose appropriate model for 3 staged Didimsae movement to Jajinmori rhythm and to provide information for ideal foot step movements. For the locational change of body center, the height of body center is lowered at the moment of forward step and during forward intersection of the feet, forward direction linear motion is converted to vertical motion to maintain stability. Speed change of body center reduces flow of body on step forward moment and controls rapid forward movement for stabled movement and position when preventing fast forward horizontal direction movement of centroid speed while knee joint and foot joint are vertically risen for heel bone contacts the ground. For angle changes of joints, in order to prevent hyperextension of lower leg, hip joint is extended and knee joint is curved to secure stability of movement for smooth curves and extension. When centroid of foot joint is moved from top of the feet to whole foot sole and when left foot makes dorsal curve, stabled movement is accomplished.

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Interaction Analysis between Construction Business Indicators and Business Performance Indicators of Civil Specialty Contractors (토목 전문건설업체의 건설경기지표와 경영성과지표의 상관성 분석)

  • Kim, Nam-Sik;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1599-1608
    • /
    • 2014
  • This study is to suggest specialty contractors with countermeasures to construction orders falling off, one of the construction business indicators for the construction industry, by analyzing the impact of dwindling construction orders to business performance indicators of specialty contractors as well as identifying inter-relationships between those performance indicators. For specialty contractors of civil construction, it is analyzed that their current ratio is significantly affecting obtention of construction orders, which in turn greatly affecting the ratio of owner's equity. It seems that the amount of construction orders has a direct relationship with the corporate stability. Therefore, this type of specialty contractors are determined to be able to obtain more orders for construction by improving current ratio.

Conjunctive Numerical Model of Surface Runoff and River Flow (지표면-하천 유출의 연계 수치모형)

  • Yu, Dong-Hun;Lee, Jeong-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.1
    • /
    • pp.91-103
    • /
    • 2001
  • In this studs, hydraulic routing model has been developed to predict the water level and discharge in each river section with considering the full interaction between surface runoff and river flow. It improved the computation of flood runoff by reflecting the shape of hydrograph that was determined by the geological and flood characteristics, and the excessive computation of the peak discharge was eliminated by considering the effect of infiltration. The Inflow from surface runoff to river flow was applied to the equation of continuity by implementing effectively the flow in a number of river section, and resulted in a numerical stability at the rapid variation of rainfall. Measurements were conducted during heavy rain in the watershed area of Yang-Yang Namdae-Chun. The present model was tested to the field, and the computed results were compared to the observed data. Its applicability was confirmed with its verification.

  • PDF

Centrifuge Modeling on Lateral Flow of Soft Soils and Displacement of Bridge Abutment on the Composite Ground (복합지반상 교대변위 및 지반 측방유동에 관한 원심모델링)

  • Heo, Yol;Park, Sunghun;Yun, Seokhyun;Kwon, Seonuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.39-46
    • /
    • 2007
  • In this study, the centrifuge tests were performed to investigate the lateral flow behavior and stability of the ground improved by SCP. The centrifuge tests were fulfilled in the case of the back of abutment filled by EPS (case 1) and soil (case 2), and the potentiometer was installed on the abutment and embankment to measure the vertical and horizontal displacement at the top of abutment. As a result, the vertical displacement measured at the back of abutment was maximum 2.1 m, which was about 12% if compared with the height of embankment. In the case of the back of abutment filled by soil, the vertical and horizontal displacement measured at the top of abutment was 10 cm and 1.1 m, respectively, which exceeded the allowable horizontal displacement. On the other hand, in the case of the back of abutment filled by EPS, the vertical displacement of abutment did nor occur and the horizontal displacement was 1.4 cm. Therefore, the effect of SCP improvement with EPS method adopted to prevent the lateral flow and assure the stability of embankment on the soft ground was far superior.

  • PDF

Study on Flow Lubrication Selection of Driving Gear Unit for EMU (전동차용 DRIVING GEAR UNIT의 윤활유량 선정에 관한 연구)

  • Kim, Kyung-Han;Lee, Tae-Hun;Kim, Hak-Soo;Seo, Young-Jin;Ko, Hyung-Keun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.132-137
    • /
    • 2011
  • Many studies are being conducted to improve high speed, light weight and safety of passenger. To improve safety of rolling stock, safety of running performance is most important, and optimizing flow lubrication in driving gear is essential. This study simulates lubricant flow change in driving gear casing which is splashed by the surface of low speed gear teeth following rotational direction of driving gear unit for EMU by using CFD analysis, and based on analysis detail, non-load actual test is conducted for similar driving condition to find out suitability of analysis, selection of lubricate and stability of driving gear.

  • PDF