• Title/Summary/Keyword: 유도방출

Search Result 346, Processing Time 0.029 seconds

Evolution of Carbofuran in Soils Treated with Its Aminothio Derivatives, Carbosulfan, Furathiocarb and Benfuracarb (Carbosulfan, Furathiocarb 및 Benfuracarb 처리토양중 Carbofuran 방출특성)

  • Lee, Young-Deuk;Choi, Ju-Hyeon
    • Korean Journal of Environmental Agriculture
    • /
    • v.14 no.2
    • /
    • pp.179-185
    • /
    • 1995
  • Three aminothio derivatives of carbofuran including carbosulfan, furathiocarb and benfuracarb were subjected to the degradation study in soils to investigate how fast and efficiently carbofuran would be evolved from them. Carbofuran was rapidly released from the derivatives in soils as the carbamoyl nitrogen-sulfur bond cleaved. Their degradation rates in soils, with half-lives of $23{\sim}68$ hours, were largely affected by structures of aminothio moieties and soil moisture conditions. Conversion rates into carbofuran ranged from 64 to 84% in soils on the basis of parent compounds 5 days after treatment. Application of aminothio derivatives led to less drastic increase in the carbofuran level in soils than when carbofuran was applied as such, and hence this might result in lower side effects in situ.

  • PDF

Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet (헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼)

  • Lee, Yonghoon;Choi, Daewoong;Gong, Yongdeuk;Nam, Sang-Ho;Nah, Changwoon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-244
    • /
    • 2013
  • Detection of halogens using laser-induced breakdown spectroscopy (LIBS) in open air is very difficult since their strong atomic emission lines are located in VUV region. In NIR region, there are other emission lines of halogens through electronic transitions between excited states. However, these lines undergo Stark broadening severely. We report the observation of the emission lines of halogens in laser-induced plasma (LIP) spectra in NIR region using a helium gas flow. Particularly, the emission lines of iodine at 804.374 and 905.833 nm from LIPs have been observed for the first time. In the helium ambient gas, Stark broadening of the emission lines and background continuum emission could be suppressed significantly. Variations of the line intensity, plasma temperature, and electron density with the helium flow rate was investigated. Detection of chlorine and bromine in flame retardant of rubbers was demonstrated using this method. Finally, we suggest a pulsed helium gas jet as a practical and ecomonical helium gas source for the LIBS analysis of halogens in open air.

유도결합플라즈마 공정에서 조건별 플라즈마 방출광 세기 변화에 따른 전자온도의 전기적, 광학적 진단에 관한 연구

  • Lee, Ye-Seul;Park, Hye-Jin;Choe, Jin-U;Kim, U-Jae;Hwang, Sang-Hyeok;Jo, Tae-Hun;Yun, Myeong-Su;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.215.1-215.1
    • /
    • 2016
  • 플라즈마는 반도체, 디스플레이, 태양전지 등 다양한 산업 분야에 이용된다. 플라즈마 공정 시 수율 향상을 위해 플라즈마를 진단하는 기술이 필요한데, 대표적으로 전자온도가 있다. 반도체 공정의 낮은 압력과 높은 밀도의 플라즈마에서 전자온도는 1~10 eV 정도인데, 0.5 eV정도의 아주 적은 차이로도 공정 결과에 큰 영향을 미친다. 플라즈마의 전자온도를 측정하는 방법은 전기적 탐침 방법인 랑뮤어 탐침(Langmuir Probe)과 와이즈 프로브(Wise Probe)를 이용한 방법, 그리고 광학적 방법인 방출분광법(OES : Optical Emission Spectroscopy)이 있다. 전기적 탐침 방법은 직접 플라즈마 내부에 탐침을 넣기 때문에 불활성 기체를 사용한 공정에서는 잘 작동하지만 건식식각이나 증착에 사용할 경우 탐침의 오염으로 인한 오동작, 공정 시 생성된 샘플에 영향을 줄 수 있다는 단점이 있다. 반면에 방출분광법은 광학적 진단으로, 플라즈마를 사용하는 공정 진행 중에 외부에 광학계를 설치하여 플라즈마에서 발생하는 빛을 광학적으로 분석하기 때문에 공정에 영향을 미치지 않고, 공정 장비에 적용이 쉬운 장점을 가지고 있다. 본 연구에서는 RF Power를 인가한 유도결합플라즈마(ICP : Inductively Coupled Plasma) 공정에서 아르곤 가스와 산소 혼합가스 분압과 인가전압을 변화시켜 플라즈마 방출광 세기 변화에 따른 전자온도를 측정하였다. 전자온도 측정에는 전기적 방법인 랑뮤어 탐침, 와이즈 프로브를 이용한 방법과 광학적 방법인 방출분광법을 사용하여 측정하였으며 이를 비교 분석하였다.

  • PDF

3극형 CNT 에미터가 장착된 초소형 X선 튜브의 제작 및 결함 분석

  • Gang, Jun-Tae;Kim, Jae-U;Jeong, Jin-U;Choe, Seong-Yeol;Choe, Jeong-Yong;An, Seung-Jun;Song, Yun-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.263.1-263.1
    • /
    • 2013
  • 탄소나노튜브(CNT)를 이용한 초소형 X선 튜브는 근접 암치료, 비파괴 X선 영상 장치, 휴대용 X선 분광계 등에서 X선 발생소스로 많이 연구되고 있다. 2극형 CNT 에미터의 경우 구조가 단순하여 초소형 X선 튜브에 쉽게 장착할 수 있지만 아노드의 전압과 전류가 연동되기 때문에 튜브의 조작성이 제한적이다. 3극형은 상대적으로 복잡한 구조이고, CNT에서 방출된 전자가 게이트 전극으로 흐르는 누설 전류 그리고 절연체와 충돌하여 차징을 발생시킬 수 있기 때문에 직경이 좁은 초소형 X선 튜브에 구현하기가 쉽지 않다. 하지만 초소형 X선 튜브를 다양한 X선 장치에 응용하기 위해서는 아노드 전압과 전류의 독립된 조작이 가능한 3극형 CNT 에미터가 반드시 구현되어야 한다. 본 발표에서는 전자빔의 아노드 집속을 강화하고 절연체에서의 차징을 줄이는 포커싱 기능의 게이트(FFG) 구조를 제안하였고. 이를 적용하여 초소형 X선 튜브들을 제작하고, 분석하였다. FFG 구조가 성공적으로 적용된 초소형 X선 튜브는 게이트 누설 전류 없이 뛰어난 전류 및 X선 방출 특성을 보였다. 이와는 달리, 몇몇 초소형 X선 튜브들에서는 게이트 누설 전류가 나타났고, 아노드 전압에 의한 게이트 전압 상승이 발생하여 불안정한 구동 특성을 보였다. 초소형 X선 튜브를 밀봉하지 않고 진공 챔버에서 실험한 결과, 유도된 게이트 전압은 상당한 시간이 흐르거나 진공챔버에 공기를 주입하고 다시 진공상태로 만들면 유도전압이 제거되는 것을 볼 수 있었다. 결론적으로 CNT에서 방출된 전자빔이 정상궤도를 벗어나 게이트 누설전류와 차징에 의한 게이트 유도전압을 발생시키면 초소형 X선 튜브가 불안정한 구동을 하고, 결국 튜브의 심각한 결함으로 나타나게 된다. 즉, 게이트 누설 전류와 유도된 게이트 전압은 3극형 CNT 에미터가 장착된 초소형 X선 튜브의 디자인과 제작에 있어서 성공 기준이 될 수 있다.

  • PDF

Synthesis of Hyaluronic Acid Scaffold for Tissue Engineering and Evaluation of Its Drug Release Behaviors (히아루론산을 이용한 조직공학용 Scaffold의 제조와 약물 방출 거동에 관한 연구)

  • Nam, Hye-Sung;Kim, Ji-Heng;An, Jeong-Ho;Chung, Dong-June
    • Polymer(Korea)
    • /
    • v.25 no.4
    • /
    • pp.476-485
    • /
    • 2001
  • In this study, we tried to design and synthesize using natural polymers (hyaluronic acid and sodium alginate) and also to make some kinds of scaffolds as sponge type for reducing the burst effect of loaded drug from them. Photo-dimerizable group was incorporated to hyaluronic acid and degradable hydrogel was prepared by the UV radiation of the polymer. The pore size and its distribution of scaffold were controlled by changing microsphere production conditions such as solution concentration and spraying pressure. It was found that drug release behavior from synthesized scaffolds was affected by hybridization of two naturally originated polymers (cinnamoylated tetrabutylammonium hyaluronate: CHT and cinnamolylated sodium alginate: CSA) and the obtained scaffolds were degraded in fairly long time (about 2 months) under in vitro environment. Therefore, we expect that obtained scaffolds can be applicable for the tissue regeneration scaffolds in the fields of orthopaedic surgery.

  • PDF

Drug Release by Poly(DL-lactide) Coated Chitosan Derivatives Matrices (Poly(DL-lactide)로 피막된 키토산 유도체 매트릭스에서의 약물방출)

  • 차월석;나재운이동병
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.461-467
    • /
    • 1995
  • In this study, the release experiments of drug were operated in the phosphate buffer solutions of pH 7.4 and pH 1.2 by using drug carriers(chitosan, chitosan hydrochloride, and sulfonated chitosan)coated by poly(DL-lactide) with prednisolone for delivery drug. The release time of drug was more delayed in pH 7.4 than in pH 1.2. The release time of according to the kinds of drug carrier was delayed in the order of chitosan, sulfonated chitosan, and chitosan hydrochloride. In short, the formulation allows biodegradable coated monolithic polymetic matrices to suppress the burst effect of the drug release mechanism, which led to the sustained release pattern.

  • PDF

Establishment of Release Limits for Airborne Effluent into the Environment Based on ALARA Concept (ALARA 개념(槪念)에 의한 기체상방사성물질(氣體狀放射性物質)의 환경방출한도(環境放出限度) 설정(設定))

  • Lee, Byung-Ki;Cha, Moon-Hoe;Nam, Soon-Kwon;Chang, Si-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.50-63
    • /
    • 1985
  • A derivation of new release limit, named Derived Release Limit(DRL), into the atomsphere from a reference nuclear power plant has been performed on the basis of the new system of dose limitation recommended by the ICRP, instead of the (MPC)a limit which has been currently used until now as a general standard for radioactive effluents in Korea. In DRL Calculation, a Concentration Factor Method was applied, in which the concentrations of long-term routinely released radionuclides were in equilibrium with dose in environment under the steady state condition. The analytical model used in the exposure pathway analysis was the one which has been suggested by the USNRC and the exposure limits applied in this analysis were those recommended by the USEPA lately. In the exposure pathway analysis, all of the pathways are not considered and some may be excluded either because they are not applicable or their contribution to the exposure is insignificant compared with other pathways. In case, the environmental model developed in this study was applied to the Kori nuclear power plant as the reference power plant, the highest DRL value was calculated to be as $9.10{\times}10^6Ci/yr$ for Kr-85 in external whole body exposure from the semi-infinite radioactive cloud, while the lowest DRL value was observed 3.64Ci/yr for Co-60 in external whole body exposure from the contaminated ground, by the radioactive particulates. The most critical exposure pathway to an individual in the unrestricted area of interest (Kilchun-Ri, 1.3 km to the north of the release point) seems to be the exposure pathway from the contaminated ground and the most critical radionuclide in all pathways appears to be Co-60 in the same pathway. When comparing the actual release rate from KNU-l in 1982 with the DRL's obtained here the release of radionuclides from KNU-1 were much lower than the DRL's and it could be conclued that the exposure to an individual had been kept below the exposure limits recommended by the USEPA.

  • PDF