• Title/Summary/Keyword: 위치정도

Search Result 3,350, Processing Time 0.037 seconds

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

Analysis of Plants Social Network for Vegetation Management on Taejongdae in Busan Metropolitan City (부산 태종대 식생관리를 위한 식물사회네트워크 분석)

  • Sang-Cheol Lee;Hyun-Mi Kang;Seok-Gon Park;Jae-Bong Baek;Chan-Yeol Yu;In-Chun Hwang;Song-Hyun Choi
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.6
    • /
    • pp.651-661
    • /
    • 2022
  • Plants social network analysis, which combines plants society and social network analyses, is a new research method for understanding plants society. This study was conducted to investigate the relationship between species, using plant social network analysis targeting Taejongdae in Busan, and build basic data for management. Taejongdae, located in the warm temperate forest in Korea, is a representative coastal forest of Busan Metropolitan City, and the Pinus thunbergii-Eurya japonicacommunity is widely distributed. This study set up 100 quadrats (size of 100m2each) in Taejongdae to investigate the species that emerged and analyzed the interspecies association focusing on major species. Based on the results, a sociogram was created using the Gephi 0.9.2, and the network centrality and structure were analyzed. The results showed that the frequency of appearance was high in the order of P. thunbergii, E. japonica, Quercus serrata, Sorbus alnifolia, Ligustrum japonicum, and Styrax japonicusand that many evergreen broad-leaved trees appeared due to the environmental characteristics of the site. The plants social network of Taejongdae was composed of a small-scale network with 50 nodes and 172 links and was divided into 4 groups through modularization. The succession sere identified through a sociogram confirmed that the group that include P. thunbergiiand E. japonicawould progress to a deciduous broadleaf community dominated by Q. serrataand Carpinus tschonoskii, using hub nodes such as Prunus serrulataf. spontaneaand Toxicodendron trichocarpum. Another succession sere was highly likely to progress to an evergreen broad-leaved community dominated by Machilus thunbergiiand Neolitsea sericea, using M. thunbergiias a medium. In some areas, a transition to a deciduous broad-leaved community dominated by Celtis sinensis, Q. variabilisand Zelkova serratausing Lindera obtusilobaand C. sinensisas hub nodes was expected.

Analysis on the Rainfall Triggered Slope Failure with a Variation of Soil Layer Thickness: Flume Tests (강우로 인한 조립토 사면에서의 토층 두께 변화에 따른 사면의 활동 분석: 실내 모형실험)

  • SaGong, Myung;Yoo, Jea-Ho;Lee, Sung-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.4
    • /
    • pp.91-103
    • /
    • 2009
  • Slope failure depends upon the climatic features related to related rainfall, structural geology and geomorphological features as well as the variation of the mechanical behaviors of soil constituting a slope. In this paper, among many variables, effects of soil layer thickness on the slope failure process, and variations of matric suction and volumetric water content were observed. When the soil layer is relatively thick, the descending wetting front decreases matric suction and the observed matric suction reaches to "0" value. When the wetting front reaches to the impermeable boundary, the bottom surface of steel soil box, ascending wetting front was observed. This observation can be postulated to be the effects of various sizes of pores. When macro size pores exist, the capillary effects can be reduced and infilling of pore will be limited. The partially filled pores would be filled with water during the ascending of the wetting front, which bounces from the impermeable boundary. This assumption has been assured from the observation of variation of the volumetric water contents at different depth. When the soil layer is thick (thickness = 20 cm), for granular material, erosion is a cause triggering the slope failure. It has been found that the initiation of erosion occurs when the top soil is fully saturated. Meanwhile, when the soil layer is shallow (thickness = 10 cm), slope slides as en mass. The slope failure for this condition occurs when the wetting front reaches to the interface between the soil layer and steel soil box. As the wetting front approaches to the bottom of soil layer, reduction of shear resistance along the boundary and increase of the unit weight due to the infiltration occur and these produce complex effects on the slope failure processes.

Limb Salvage Using a Combined Distal Femur and Proximal Tibia Replacement in the Sequelae of an Infected Reconstruction on Either Side of the Knee Joint (슬관절 주위 재건물 감염 후유증 시 슬관절 상하부 종양인공관절을 이용한 사지 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Park, Hwanseong;Nam, Heeseung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Purpose: Tumor infiltration around the knee joint or skip metastasis, repeated infection sequelae after tumor prosthesis implantation, regional recurrence, and mechanical failure of the megaprosthesis might require combined distal femur and proximal tibia replacement (CFTR). Among the aforementioned situations, there are few reports on the indication, complications, and implant survival of CFTR in temporarily arthrodesed patients who had a massive bony defect on either side of the knee joint to control infection. Materials and Methods: Thirty-four CFTR patients were reviewed retrospectively and 13 temporary arthrodesed cases switched to CFTR were extracted. All 13 cases had undergone a massive bony resection on either side of the knee joint and temporary arthrodesis state to control the repeated infection. This paper describes the diagnosis, tumor location, number of operations until CFTR, duration from the index operation to CFTR, survival of CFTR, complications, and Musculoskeletal Tumor Society (MSTS) score. Results: According to Kaplan-Meier plot, the 5- and 10-year survival of CFTR was 69.0%±12.8%, 46.0%±20.7%, respectively. Six (46.2%) of the 13 cases had major complications. Three cases underwent removal of the prosthesis and were converted to arthrodesis due to infection. Two cases underwent partial change of the implant due to loosening and periprosthetic fracture. The remaining case with a deep infection was resolved after extensive debridement. At the final follow-up, the average MSTS score of 10 cases with CFTR was 24.6 (21-27). In contrast, the MSTS score of 3 arthrodesis cases with failed CFTR was 12.3 (12-13). The average range of motion of the 10 CFTR cases was 67° (0°-100°). The mean extension lag of 10 cases was 48° (20°-80°). Conclusion: Although the complication rates is substantial, conversion of an arthrodesed knee to a mobile joint using CFTR in a patient who had a massive bony defect on either side of the knee joint to control infection should be considered. The patient's functional outcome was different from the arthrodesed one. For successful conversion to a mobile joint, thorough the eradication of scar tissue and creating sufficient space for the tumor prosthesis to flex the knee joint up to 60° to 70° without soft tissue tension.

Study on Nozzle Type and Proper Discharge Pressure of Sprayer for Vehicle Disinfecting System (차량소독장치용 노즐형태와 분무기의 적정토출압력에 관한 연구)

  • Lim, Young-Il;Chang, Dong-Il;Kim, Jeong-Chul;Park, Dong-Suk;Lee, Seung-Joo;Kang, Beom-Sun;Kim, Suk;Gutierrez, Winson M.;Lee, Tae-Hoon;Choi, Chung-Heon;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.119-127
    • /
    • 2016
  • The current disinfection method of vehicles being applied in South Korea has various shortcomings. So, the epidemic has generated continuously at livestock farms. It is very important to develop an effective disinfection system for reduction of the epidemic. And various basic data is required for this development. Therefore, this study was performed to identify the nozzle type and proper discharge pressure of sprayers. The experiment was conducted from January 10, 2012 until February 28, 2012. All the performance measurement experiments were repeated five times. The subjects of experiment were the A, B and C company's products. The sprayed capacity, angle of spray and the covering area ratio were measured for each product. As a result, the sprayed capacity, angle of spray and the covering area ratio were increased as the discharge pressure of the sprayer was increased. In conclusion, the conical shaped of the nozzle is considered more appropriate than V-shaped, and the proper discharge pressure is expected to be at least 20kg/㎠.

A Study on the Awareness & Preferences about the Nursing Homes (노인요양시설에 대한 고령자 인식 및 시설 내부 색채선호 경향에 관한 연구)

  • Jeong, Mu Lin;Park, Hey Kyung
    • Korea Science and Art Forum
    • /
    • v.29
    • /
    • pp.319-331
    • /
    • 2017
  • South Korea has entered the age of aging society since the elderly population over 65 reached 13.1% in 2015. This increase rate is the fastest in the OECD members. as a part of the precaution, the Korean government has enforced the long term care insurance from July 2008 and the increase of related nursing homes until 2015 was 220.2% which is rapid and quantitative. It was natural that quantitative expansion leads to qualitative improvement. With regard to service environment conditions, color environment draws attention as one of the most effective measures. color environment supports nursing home's spatial functions and the aged class is subject to the research as the potential customers. This study aims to understand color environment, conduct surveys for color preference and attitude toward color environment, and suggest directions for color environment plan. The ultimate goal is to improve the quality of Korean nursing home environment. It studied definition, state, color environment and space functions of nursing homes as well as the preceding researches. With 100 people over 60s in Busan and Gyeongnam area (52 male and 48 female), the survey examined attitudes for color environment and color preference by space functions in nursing home. The research method is as follows. First, as a result of the consciousness survey on color environment in elderly nursing home, it considers service (37%), medical service (20%), and location (19%) heavily in order. color environment plan is not recognized significantly. However, the need of indoor color plan in the elderly nursing homes has "agree (32%) and "strongly agree (25%), which suggests that color introduction is required to the nursing homes. Second, the indoor coloration for the elderly nursing homes has various color preferences. The color preference order for bedroom was R, P, and G but this order changes in nursing space (program room) to G, R, and Y. The communal space such as lobby prefers R, G and Y in order. R color was preferred in general.

Pre-service mathematics teachers' noticing competency: Focusing on teaching for robust understanding of mathematics (예비 수학교사의 수학적 사고 중심 수업에 관한 노티싱 역량 탐색)

  • Kim, Hee-jeong
    • The Mathematical Education
    • /
    • v.61 no.2
    • /
    • pp.339-357
    • /
    • 2022
  • This study explores pre-service secondary mathematics teachers (PSTs)' noticing competency. 17 PSTs participated in this study as a part of the mathematics teaching method class. Individual PST's essays regarding the question 'what effective mathematics teaching would be?' that they discussed and wrote at the beginning of the course were collected as the first data. PSTs' written analysis of an expert teacher's teaching video, colleague PSTs' demo-teaching video, and own demo-teaching video were also collected and analyzed. Findings showed that most PSTs' noticing level improved as the class progressed and showed a pattern of focusing on each key aspect in terms of the Teaching for Robust Understanding of Mathematics (TRU Math) framework, but their reasoning strategies were somewhat varied. This suggests that the TRU Math framework can support PSTs to improve the competency of 'what to attend' among the noticing components. In addition, the instructional reasoning strategies imply that PSTs' noticing reasoning strategy was mostly related to their interpretation of noticing components, which should be also emphasized in the teacher education program.

A Inquiry of Zhang Bo-duan's Writings (장백단(張伯端)의 저술고(著述考))

  • Kim, Kyeongsoo
    • The Journal of Korean Philosophical History
    • /
    • no.29
    • /
    • pp.255-280
    • /
    • 2010
  • Zhang Bo-duan compiled about internal alchemy in Taoism. Although he lived in the mundane world, he wished to seek theory on neidan of Taoism(internal alchemy). After finding enlightenment, he elucidated that the enlightenment was a state of rising above world not needed to leave the world. After ages, he was admired as the founder of Taoism in Southern school and his Oh Jin Peon which contents internal alchemy was considered seriously to have more than 30 people who annotated with it until Ch'ing Empire. At his age of 80, he met the real person who gave him theory on neidan of Taoism(internal alchemy), its preface tells that he organized its main point, and then wrote Oh Jin Peon with it in 1075. Generally Zhang Bo-duan was known to leave three books as Oh Jin Peon, Guem Dan Sa Baek Ja, and Cheung Hwa Bi Mun, most of critics have been studying on the basis of them. However, it is not correct whether all of them is his writings and there is not exact analysis but simple belief about it. I think accuracy and details are indispensible in philosophical approach. The study not having verification about primary data is no more than a visionary projet which soon collapses. So the purpose of this study is adding the detail analysis on it and making its exact basis of philosophical approach. Zhang Bo-duan over his age of 80, became enlightened, in his old age handed down his student the secret as a record and theory on neidan of Taoism(internal alchemy). And not in his living but after his dying his status was soared. Because of his high status in internal alchemy Taoism, it seems that there are more interest in it and some published books which just leave his name. In this study, I accept Oh Jin Peon as a his real writing among unsure his writings and criticize systematically and classify its characteristics. And I demonstrate that Guem Dan Sa Baek Ja, Cheung Hwa Bi Mun couldn't be his real writings, these could be forgeries by posterity, with proposing some basis of the argument.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Preliminary Study on the Genesis and Nickel Potential of Ultramafic Rocks in Chungnam Yugu area, South Korea (충남 유구지역 초염기성암의 성인과 니켈 잠재성에 대한 예비연구)

  • Ijeung Kim;Sang-Mo Koh;Otgon-Erdene Davaasuren;Gi Moon Ahn;Chul-Ho Heo;Bum Han Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.4
    • /
    • pp.323-336
    • /
    • 2023
  • We investigated the nickel potential and genesis of ultramafic rocks in the Yugu area to secure nickel resources in South Korea. The Yugu ultramafic rocks, located in the southwest of the Gyeonggi Massif, are characterized by spinel peridotite and exhibit strong serpentinization along their boundaries. The serpentinization is observed as olivine transformed to antigorite and chrysotile, while pentlandite, the nickel sulfide mineral, altered into millerite and awaruite. Serpentine displays distinct foliation, aligning subparallel to the ultramafic rock boundaries and foliation of Yugu gneiss. This suggests that the uplift of ultramafic rocks resulted in hydrothermal infiltration likely sourced from the Yugu gneiss metamorphism. The Yugu ultramafic rocks are residues after 5~18% partial melting of abyssal peridotite. Enriched light rare earth elements and Eu imply secondary metasomatism. Geochemistry suggests a link between the formation of Yugu ultramafic rock and the Triassic collision of the North and South China continents. The nickel content is around 0.17~0.21%, mainly contained in olivine and serpentine. Hence, in addition to the mineral processing study on the sulfide minerals, focused studies on oxide minerals for enhanced nickel recovery within the Yugu ultramafic rock are strongly suggested.