Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

A study on the interaction between visual perception and the body in contemporary painting space (20세기 회화공간에서 시지각과 신체의 상관성에 관한 연구)

  • Lee, Kum-Hee
    • Journal of Science of Art and Design
    • /
    • v.11
    • /
    • pp.109-152
    • /
    • 2007
  • This thesis started from accepting the criticism and concretely seeking the possibility of visual visuality, in particular, visual physicality or physical visuality through the expression revealed in painting space. This study aims at stressing the role of the body in visual perception and pictorial expression by it by examining the interaction between it and the body. First of all, this study explored perception and the position of the body in the great frame of the historical stream from modernism, through minimalism, through post-minimalism to later art in order to confirm the interaction between visual perception and the body or the change in the intervention of physicality in the stream of contemporary art, and connected them with a discourse on perception and the body. It raised as the grounds for it the discussions which provided the theoretical background about perception. It dealt with the scientific discussions on perceptual physicality by Gestalt psychology in perceptive psychology, and next the discussion of Rudolf Arnheim who exemplified Gestalt psychology mainly on the dimension of visual art. It is significant in explaining the perceptual activeness which is the same as that of M. Merleau-Ponty as a primary debater to solve the questions of perceptual physicality and physical visuality. M. Merleau-Ponty set forth ambiguous perception and the body as its background as the fundamental bases for perceiving the world rather than consciousness proved explicitly. As Hal Foster said, as minimalist phenomenological background they provided appropriate theoretical background to the late art rising against modernist logic. Next, after the 1970s Frank Stella showed a working method and a tendency entirely different from those in the previous period. For example, deconstruction of frame, decentralized spatial expression, dynamic and mixed expression, and allowing real space by overlapping were judged to swing to approval of perceptual physicality. Francis Bacon's painting structure, that is, figure, triptych, aplat and a method of production by accident were understood to well reflect M. Merleau-Ponty's chair logic of chiasme. This study tries to seek the possibility of pictorial expression from works aiming at defining the question of seeing in connection with physicality, the role of the body as the body accumulated and the linking with a real, daily life as the background of the body, and confirm the phase shift.

  • PDF

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.

The Effect of a Bypass Operation for Atherosclerotic Arterial Obstructive Disease at the Lower Extremity (동맥경화성 하지 동맥 폐색증에 대한 우회로 수술의 효과)

  • Choi, Won-Suk;Park, Jae-Min;Lee, Yang-Haeng;Han, Il-Yong;Jun, Hee-Jae;Yoon, Young-Chul;Hwang, Youn-Ho;Cho, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.610-618
    • /
    • 2008
  • Background: There are various treatment modalities for atherosclerotic arterial obstructive disease at the lower limbs, for example, conservative physical therapy, medication, operation etc. Yet it has been established that an arterial bypass operation is the most effective treatment. The aim of this study is to evaluate the effect of arterial bypass operation within our experience and to determine the indicators of treatment. Material and Method: Ninety six patients received arterial bypass operation for atherosclerotic arterial obstructive disease from June 2002 to April 2006. We evaluated the feasibility of arterial bypass operation based on the improvement of symptoms and the ankle-brachial index (ABI) and the surgical outcomes, as based on the complications, the amputation rates and the patency rates. We also assessed the possible risk factors such as gender, age, a smoking history, co-morbidities, the anastomotic sites, the graft size and the graft type. We retrospectively reviewed the medical records of the patients. The total mean follow-up period was $29.4{\pm}13.1$ months. Result: The mean age was $65.95{\pm}9.61$ and there were 88 male patients. The most common clinical manifestation was ischemic resting pain in the lower extremities. The underlying combined diseases were hypertension (61%), diabetes (43%), cardiac problems (35%) and smoking (91.7%). The most frequent site of arterial obstruction was the superficial femoral artery (44 cases, 40%). A femoropopliteal artery bypass operation with a Polytetrafluoroethylene(PTFE) synthetic graft was done in 44 cases (40%) and the great saphenous vein graft was used in 11 cases. The postoperative ABI increased significantly from $0.30{\pm}0.11$ preoperatively to $0.63{\pm}0.11$ (p<0.001) postoperatively. In 8 cases, amputations above the ankle level were necessary. The graft patency rates were 86.4% and 68.0% after 1 and 3 years, respectively. There were 29 cases (30.21%) of patency failure; the male gender, smokers and hypertension were significantly more frequent in the failure group. Of these, hypertension was the most powerful risk factor (p=0.042). Conclusion: The arterial bypass operation is an effective treatment modality for controlling the symptoms such as pain and claudication, and for preventing major amputations for the patients with atherosclerotic arterial obstructive disease. This study suggests quitting smoking, strict blood pressure control, selection of an appropriate graft, regular outpatient follow up and proper medication would offer higher patency rates and more favorable outcomes.

Studies on Glycolipids in Bacteria -Part II. On the Structure of Glycolipid of Selenomonas ruminantium- (세균(細菌)의 당지질(糖脂質)에 관(關)한 연구(硏究) -제2보(第二報) Selenomonas ruminantium의 당지질(糖脂質)의 구조(構造)-)

  • Kim, Kyo-Chang
    • Applied Biological Chemistry
    • /
    • v.17 no.2
    • /
    • pp.125-137
    • /
    • 1974
  • The chemical structure of glycolipid of Selenomonas ruminantium cell wall was to be elucidated. The bacterial cells were treated in hot TCA and the glycolipid fractions were extracted by the solvent $CHCl_3\;:\;CH_3OH$ (1 : 3). The extracted glycolipids fraction was further separated by acetone extraction. The acetone soluble fraction was named as the spot A-compound. The acetone insoluble but ether soluble fraction was named as the spot B-compound. These two compounds were examined for elucidation of their chemical structure. The results were as follows: 1. The IR spectral analysis showed that O-acyl and N-acyl fatty acids were linked to glucosamine moiety in the spot A-compound. However in the spot B-compound in addition to O and N-acyl acids phosphorus was shown to be attached to glucosamine. 2. It was recognized by gas liquid chromatography that spot A compound contained beta-OH $C_{13:0}$ fatty acid in predominance in addition to the fatty acid with beta-OH $C_{9:0}$, whereas the spot B compound was composed of the predominant fatty acid of beta-OH $C_{13:0}$ with small amount of beta-OH $C_{9:0}$. 3. According to the paper chromatographic analysis of hydrazinolysis products of the spot A compound, a compound of a similar Rf value as the chitobiose was recognized, which indicated a structure of two molecules glucosamine condensed. The low Rf value of the hydrazinolysis product of the spot B-compound confirmed the presence of phosphorus attached to glucosamine. 4. The appearance of arabinose resulting from. ninhydrin decomposition of the acid hydrolyzate of the spot A compound indicated that the amino group is attached to $C_2$ of glucosamine. 5. The amount of glucosamine in the N-acetylated spot A compound decreased in half of the original content by the treatment. with $NaBH_4$, indicating that there are two molecules of glucosamines in the spot A compound. The presence of 1, 6-linkage between two molecules of glucosamine was suggested by the Morgan-Elson reaction and confirmed by the periodate decomposition test. 6. By the action of ${\beta}-N-acetyl$ glucosaminidase the N-acetylated spot A compound was completely decomposed into N-acetyl glucosamine, whereas the spot B compound was not. This indicated the spot A compound has a beta-linkage. 7. When phosphodiesterase or phosphomonoesterase acted on $^{32}P-labeled$ spot B compound, $^{32}P$ was not released by phosphodiesterase, but completely released by phosphomonoesterase. This indicated that one phosphorus is linked to glucosamine moiety. 8. The spot A compound is assumed to have the following chemical structure: That is glucosaminyl, ${\beta}-1$, 6-glucosamine to which O-acyl and N-acyl fatty acids are linked, of which the predominant fatty acid is beta-OH $C_{13:0}$ fatty acid in addition to beta-OH $C_{9:0}$ fatty acid 9. The spot B compound is likely to have the linkage of $glucosaminyl-{\beta}-1$, 6-glucosamine to which phosphorus is linked in monoester linkage. Furthermore both O-acyl and N-acyl fatty acids contained beta-OH $C_{13:0}$ fatty acid predominantly in addition to beta-OH $C_{9:0}$ fatty acid.

  • PDF

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Effect of Dose Rate Variation on Dose Distribution in IMRT with a Dynamic Multileaf Collimator (동적다엽콜리메이터를 이용한 세기변조방사선 치료 시 선량분포상의 선량률 변화에 따른 효과)

  • Lim, Kyoung-Dal;Jae, Young-Wan;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Purpose: To evaluate dose distribution differences when the dose rates are randomly changed in intensity-modulated radiation therapy using a dynamic multileafcollimator. Materials and Methods: Two IMRT treatment plans including small-field and large-field plans were made using a commercial treatment planning system (Eclipse, Varian, Palo Alto, CA). Each plan had three sub-plans according to various dose rates of 100, 400, and 600 MU/min. A chamber array (2D-Array Seven729, PTW-Freiburg) was positioned between solid water phantom slabs to give measurement depth of 5 cm and backscattering depth of 5 cm. Beam deliveries were performed on the array detector using a 6 MV beam of a linear accelerator (Clinac 21EX, Varian, Palo Alto, CA) equipped with 120-leaf MLC (Millenium 120, Varian). At first, the beam was delivered with same dose rates as planned to obtain reference values. After the standard measurements, dose rates were then changed as follows: 1) for plans with 100 MU/min, dose rate was varied to 200, 300, 400, 500 and 600 MU/min, 2) for plans with 400 MU/min, dose rate was varied to 100, 200, 300, 500 and 600 MU/min, 3) for plans with 600 MU/min, dose rate was varied to 100, 200, 300, 400 and 500 MU/min. Finally, using an analysis software (Verisoft 3.1, PTW-Freiburg), the dose difference and distribution between the reference and dose-rate-varied measurements was evaluated. Results: For the small field plan, the local dose differences were -0.8, -1.1, -1.3, -1.5, and -1.6% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +0.9, +0.3, +0.1, -0.2, and -0.2% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.4, +0.8, +0.5, +0.3, and +0.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). On the other hand, for the large field plan, the pass-rate differences were -1.3, -1.6, -1.8, -2.0, and -2.4% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +2.0, +1.8, +0.5, -1.2, and -1.6% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.5, +1.9, +1.7, +1.9, and +1.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). In short, the dose difference of dose-rate variation was measured to the -2.4~+2.0%. Conclusion: Using the Varian linear accelerator with 120 MLC, the IMRT dose distribution is differed a little <(${\pm}3%$) even though the dose-rate is changed.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Clinical Features of Acute Nonspecific Mesenteric Lymphadenitis and Factors for Differential Diagnosis with Acute Appendicitis (급성 비특이성 장간막 림프절염의 임상 소견과 급성 충수돌기염과의 감별 인자)

  • Shin, Kyung Hwa;Kim, Gab Cheol;Lee, Jung Kwon;Lee, Young Hwan;Kam, Sin;Hwang, Jin Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • Purpose: Although acute nonspecific mesenteric lymphadenitis (ANML) is probably common cause of abdominal pain in children, which can be severe enough to be an abdominal emergency, the clinical features of mesenteric lymphadenitis are not clear. Also, a differential diagnosis with acute appendicitis (APPE) is indispensable to avoid serious complications. The clinical features of ANML were determined, and the risk factors for differential diagnosis with APPE were analyzed. Methods: Between November 2000 and May 2001, data from 26 patients (aged 1 to 11 years) with ANML and 21 patients (aged 2 to 13 years) with APPE were reviewed. ANML was defined as a cluster of five or more lymph nodes measuring 10 mm or greater in their longitudinal diameter in the right lower quadrant (RLQ) without an identifiable specific inflammatory process on the ultrasonographic examination. There were risk factors on patient's history, physical examination, and laboratory examination; the location of abdominal pain, abdominal rigidity, rebound tenderness, fever, nocturnal pain, the vomiting intensity, the diarrhea intensity, the symptom duration, and the peripheral blood leukocytes count. Results: Of the 26 ANML patients and 21 APPE patients, abdominal pain was noted on periumbilical (76.9% vs 14.2%), on RLQ (11.5% vs 71.4%), with abdomen rigidity (7.6% vs 80.9%), with rebound tenderness (0.0% vs 76.1%)(p<0.05), in the lower abdomen (11.5% vs 14.2%), and at night (80.8% vs 100.0%) (p>0.05). The clinical symptoms were vomiting (38.4% vs 90.4%), the vomiting intensity ($1.5{\pm}0.7$ [1~3]/day vs $4.5{\pm}2.9$ [1~10]/day), diarrhea (65.3% vs 28.5%) (p<0.05), and fever (61.5% vs 76.2%)(p>0.05). The period to the subsidence of abdominal pain in the ANMA patients was $2.5{\pm}0.5$ (2~3) days. The laboratory data showed a significant difference in the peripheral blood leukocytes count ($8,403{\pm}1,737[5,900{\sim}12,300]/mm^3\;vs\;15,471{\pm}3,749[5,400{\sim}20,800]/mm^3$)(p<0.05). Discriminant analysis between ANML and APPE showed that the independent discriminant factors were a vomiting intensity and the peripheral blood leukocytes count and the discriminant power was 95.7%. Conclusion: The clinical characteristics of ANML were abrupt onset of periumbilical pain without rigidity or rebound tenderness, a mild vomiting intensity, normal peripheral leukocytes count, and relatively short clinical course. If the abdominal pain persist for more than 3 days, and/or the vomiting intensity is more than 3 times/day, and/or the peripheral leukocytes count is over $13,500/mm^3$, abdominal ultrasonography is recommended to rule out APPE.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.