• Title/Summary/Keyword: 원자방출분광법

Search Result 63, Processing Time 0.032 seconds

Rare Earth Element Analysis with Chromatography-Inductively Coupled Plasma Atomic Emission Spectrometry and the Comparison of Cross Flow and Ultrasonic Nebulizers (크로마토그래피-유도 결합 플라스마 원자방출 분광법을 이용한 희토류 원소들의 연속적 분석 및 직교형과 초음파분무기의 비교)

Simultaneous Determination of Sulfur, Phosphorus, and Zine in Lubricating Oils by Microwave Digestion System and ICP-AES (마이크로파 분해장치와 유도결합 플라스마 원자방출분광법을 이용한 윤활유 시료 중 S, P 및 Zn의 동시 분석)

  • Cho, Sung-Ill;Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.324-330
    • /
    • 2001
  • For the analysis of S, P and Zn in lubricating oil, microwave digestion method was studied by using inductively coupled plasma-atomic emission spectrometry(ICP-AES). Lubricating oil was completely decomposed with nitric acid or a mixture of nitric acid and hydrogen peroxide using and closed microwave digestion system. Digestions are completed within 50 min, a factor of at least 3~4 times faster than for the conventional digestion. A gradual heating program operated by the pulsed mode was found suitable for decomposing the lubricating oil matrix safely. The proposed method of digestion gave relative standard deviations(RSD) less than 3% for the elements determined.

  • PDF

Determination of calcium content and dissolution characteristics of oyster shell by ICP-AES (유도결합플라즈마 원자방출분광법을 이용한 모려 칼슘의 함량 및 용출 특성 분석)

  • Yang, Dong-Hyug;Lee, Mi-Young
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.389-394
    • /
    • 2010
  • An ICP-AES method for determination of calcium content and dissolution characteristics of oyster shell (Ostrea gigas) has been developed and validated. Total calcium content in oyster shell was determined using ICPAES. The dissolution characteristics, which would reflect the composition of $CaCO_3$ polymorphs and calcium salts in oyster shell, were also evaluated by dissolution test. The total calcium contents ranged from 31.8 to 39.9% and the dissolution ratios varied from 62.7 to 83.6% (n=15). The determination of calcium content and dissolution characteristics by ICP-AES would provide useful information for the quality control of oyster shell.

Qualitative and Quantitative Analysis of Space Minerals using Laser-Induced Breakdown Spectroscopy and Raman Spectroscopy (레이저 유도 분해 분광법과 라만 분광법을 이용한 우주 광물의 정성 및 정량 분석 기법)

  • Kim, Dongyoung;Yoh, Jack J.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.519-526
    • /
    • 2018
  • In order to analyze space resources, it had to be brought to earth. However, using laser-induced breakdown spectroscopy(LIBS) and Raman spectroscopy, it is possible to analyze qualitative and quantitative analysis of space minerals in real time. LIBS is a spectroscopic method in which a high energy laser is concentrated on a material surface to generate a plasma, and the emitted light is acquired through a spectroscope to analyze the atomic composition. Raman spectroscopy is a spectroscopic method that analyzes the molecular structure by measuring scattered light. These two spectroscopic methods are complementary spectroscopic methods for analyzing the atoms and molecules of unknown minerals and have an advantage as space payloads. In this study, data were analyzed qualitatively by using principal component analysis(PCA). In addition, a mixture of two minerals was prepared and a quantitative analysis was performed to predict the concentration of the material.

Simultaneous Determination of Mercury and Arsenic by Reductive Vapor Generation-ICP-AES (환원 증기 발생법-유도결합 플라즈마 원자방출 분광계를 이용한 수은과 비소의 동시 분석법)

  • Shin, Hyung-Seon;Choi, Man-Sik;Kim, Kang-Jin
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.273-278
    • /
    • 1999
  • Simultaneous determination of mercury and arsenic has been studied by reductive vapor generation-ICP-AES. Samples were digested with a microwave digestion system and extracted with acids. Reductive vapor generation was carried out with 6N HCI and 2% $NaBH_4$. Detection limit of Hg and As are found to be 0.06 ppb and 0.08 ppb, respectively. Measured values of Hg and As in inorganic samples agree well with reference value of SRMs, but the recovery of As from organic samples is obtained approximately 80% of the reference values.

  • PDF

Some Effects of Acid Concentrations in Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry (유도결합 플라즈마 원자방출분광법 및 질량분석법에서 산의 농도에 의한 영향)

  • Cho, Man-Sik;Lim, Heoungbin;Kim, Young-Sang;Lee, Kwang-Woo
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.277-283
    • /
    • 1992
  • Acid effects on the ICP-AES signals are studied as the concentrations of nitric acid, hydrochloric acid, sulfuric acid, and 1:1 mixture of nitric acid and hydrochloric acid are changed. Almost all analyte signals are depressed. The extent of the depression due to the pressence of the acids became to be pecular when the acid concentration was over 1%. Among the acids used, the suppression due to sulfuric acid is most severe and unexpectable. The ratios of the analyte signal to Ar signal and the Mg II signal to Mg I signal are measured as the concentration of the acids changed. In this study, it is proved that the main reason of the signal reduction is the change in the nebulization efficiency, for example, droplet size distribution, viscosity and surface tension variation, not the alteration of plasma excitation characteristics. There was no relationship found between ionization potential and analyte signal reduction in ICP-MS.

  • PDF

Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet (헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼)

  • Lee, Yonghoon;Choi, Daewoong;Gong, Yongdeuk;Nam, Sang-Ho;Nah, Changwoon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-244
    • /
    • 2013
  • Detection of halogens using laser-induced breakdown spectroscopy (LIBS) in open air is very difficult since their strong atomic emission lines are located in VUV region. In NIR region, there are other emission lines of halogens through electronic transitions between excited states. However, these lines undergo Stark broadening severely. We report the observation of the emission lines of halogens in laser-induced plasma (LIP) spectra in NIR region using a helium gas flow. Particularly, the emission lines of iodine at 804.374 and 905.833 nm from LIPs have been observed for the first time. In the helium ambient gas, Stark broadening of the emission lines and background continuum emission could be suppressed significantly. Variations of the line intensity, plasma temperature, and electron density with the helium flow rate was investigated. Detection of chlorine and bromine in flame retardant of rubbers was demonstrated using this method. Finally, we suggest a pulsed helium gas jet as a practical and ecomonical helium gas source for the LIBS analysis of halogens in open air.

Direct Determination of Tellurium in Simulated Nuclear Spent Fuels by Hydride Generation-Inductively Coupled Plasma Atomic Emission Spectrometry (수소화물 생성-유도결합플라스마 원자방출분광법을 이용한 모의사용후 핵연료 중의 텔루르 분석)

  • Choi, Kwang Soon;Lee, Chang Heon;Han, Sun Ho;Joe, Kih Soo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.781-788
    • /
    • 2000
  • Tellurium in simulated nuclear spent fuels (SIMFUEL) has been determined by hydride generation-inductively coupled plasma atomic emission spectrometry (HG-ICP-AES). Parameters such as concentrations of HCl and $NaBH_4$, flow rate of HCl and $NaBH_4$ were optimized and then the effects of U, Mo, Pd, Rh and Ru on the Te intensity were investigated. A thiourea as a masking agent was used to eliminate or minimize such interferences specially caused by palladium. Tellurium was measured by HG-ICP-AES and ICP-MS after separation of tellurium from SIMFUEL with cation exchange chromatography. The relative deviation between direct measurement and separation method was less than 6% based on the data by ICP-MS.

  • PDF