• Title/Summary/Keyword: 원심 블로어

Search Result 8, Processing Time 0.024 seconds

Performance Enhancement of Dual-Inlet Centrifugal Blower by Optimal Design of Splitter (스플리터 형상최적화에 의한 양흡입 원심블로어 성능개선)

  • Lee, Jong Sung;Jang, Choon Man
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1065-1072
    • /
    • 2014
  • The shape of an impeller splitter for a dual-inlet centrifugal blower was optimized to enhance the blower performance. Two design variable, the normalized chord and pitch of a splitter, were used to evaluate the blower performance and internal flow fields based on the three-dimensional flow analysis. The blower performance obtained using this numerical simulation had a maximum error of 4 percent compared to that in an experiment at the design flow condition. The shape optimization of the splitter successfully increased the blower efficiency and pressure by 3.65 and 1.14 percent compared to the reference values. The blower performance was increased by reducing the flow separation near the blade suction surface by optimizing the shape of the splitter, which produced a pressure increase at the outlet of the volute casing.

Development of Turboblower for Fuel Cell Automobile Applications (연료전지 자동차용 터보블로어 개발)

  • Kwon Hyuckroul;Park Hyungkeun;Kim Seongkyun;Kim Chimyung;Park Yongsun;Hwang Inchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.345-348
    • /
    • 2005
  • 본 개발의 목적은 연료전지차량에 탑재되는 연료전지 시스템에 장착될 공기공급기를 개발하는 것이었다. 개발된 공기공급기의 형태는 공급해야 할 공기의 유량과 압력 범위, 소음 및 향후 양산성 등을 고려하여 원심형 블로어를 선택하였으며, 차량 부하에 따른 공기공급량을 제어하기 위한 제어기도 적용되었다. 또한 차량에 적용될 경우, 예상되는 가혹한 사용환경에서 안정적인 성능을 발휘하고, 내구성을 할 수 있도록 설계되었으며, 특히, 외기온도 $45^{\circ}C$에서도 충분한 방열성능을 갖도록 모터 및 모터 방열구조를 설계하였다. 이를 위하여 공급되는 공기로 직접 모터를 냉각하는 개념을 적용하였다. 개발된 터보블로어의 응답성을 포함한 성능평가를 수행하였으며, 설계점에서 600시간 연속운전을 통하여 기본 내구평가를 완료하였다.

  • PDF

Operating Characteristics of Serially Connected Centrifugal Blowers Used for Automated Vacuum Waste Collection System (생활폐기물 자동집하시설용 다단직렬연결 원심블로어 운전특성)

  • Jang, Choon-Man;Lee, Jong-Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.4
    • /
    • pp.40-46
    • /
    • 2014
  • This paper describes blower performance characteristics of a automated vacuum waste collection system. Blowers serially connected to six or seven centrifugal blowers are evaluated by experimental measurements to understand blower performances according to blower numbers operated. Two different blowers and duct diameters connected to the main blowers are considered. Data acquisition system is introduced to measure pressure and pressure difference at the main duct simultaneously, which is connected to several blowers serially. A auxiliary blower, which is installed between a filter room and an air deodorizing apparatus, is also added to simulate its performance effect on the main blower. Throughout the experimental measurements of the blower system, it is found that pressure and inlet velocity at the upstream of a blower increase 3.7 and 2.4 times separately by increasing the operating blower numbers from one to seven. It is noted that blower efficiency and pressure measured at the system vary according to the distance between a air intake and a blower system. Auxiliary blower is effective to increase blower inlet suction pressure, while total energy consumption is increased relatively.

Quantitative Visualization of Inlet Flow of the Centrifugal Blower (원심 블로어 입구 유동의 정량적 가시화 연구)

  • Jeong, Tae-Sik;Tu, Xin Cheng;Kim, Sung-Jun;Jang, Hwan-Young;Kim, Jin-Kwang;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.2
    • /
    • pp.27-33
    • /
    • 2013
  • The inlet flow of centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower system is one of the key parts of EV battery cooling system, the quantitative information of flow field of centrifugal blower is important to design and optimize the cooling system. Two types of inlet parts were used in this study. One is the straight inlet and the other is a bended one. The results showed the flow asymmetry exists in the straight model due to the pressure difference in the blower. In case of the bended one, the separation bubble and the increase of head loss appeared compared with the straight model.

Performance Characteristics according to the Outlet Impeller Blade Shape of a Centrifugal Blower (원심블로어 임펠러 토출 날개 형상에 따른 성능특성)

  • Lee, Jong-Sung;Jeon, Hyun-Jun;Jang, Choon-Man
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • This paper presents the performance characteristics of a centrifugal blower using the design parameters of an impeller blade. Two design variables, the bending length from the blade trailing edge and bending angles of an impeller blade, are introduced to analyze the effects on the blower performance. Three-dimensional Navier-Stokes equations with shear stress transport turbulence model are introduced to analyze the performance and internal flow of the blower. Relatively good agreement between experimental measurements and numerical simulation at the design flow condition is obtained. Throughout present study, it is known that pressure increases as the bending length from the trailing edge and bending angle increase while efficiency decreases. But efficiency is decreased. Detailed flow field inside the centrifugal blower is also analyzed and compared.

Quantitative Visualization of Outlet Flow of the Centrifugal Blower (원심 블로어 출구 유동의 정량적 가시화 연구)

  • Tu, Xin Cheng;Kim, Sung-Jun;Park, Seung Ha;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.25-29
    • /
    • 2014
  • The outlet flow of the centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower is one of the key parts of electric vehicle battery cooling system, the quantitative information of centrifugal blower is necessary to design and optimize the cooling system. The effect of different inlet flow condition to the outlet flow was investigated in this study. Two different inlet ducts were used. One is the straight inlet and the other is a bended one. The results clearly showed the outlet flow asymmetry in both inlet ducts. When the blower has the bended inlet, the flow rate decreases due to the increase of the head loss.

Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower (산업용 원심블로어 수치해석을 위한 수치모델 평가)

  • Lee, Jongsung;Jang, Choonman
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.6
    • /
    • pp.688-695
    • /
    • 2012
  • The present study represents the effects of boundary condition on the performance of a centrifugal blower at the interference plane between rotational and stationary domains using three dimensional compressible Navier-Stocks equations. Two boundary conditions, frozen-rotor and stage, are compared to analyze the blower performance. Installation angle between the cutoff of a volute casing and a impeller blade is also introduced to evaluate the blower performance and to understand the internal flow inside the blower. Throughout numerical simulation, it is found that the frozen rotor interface method at the interference plane represents well the variations of flow field inside the blower compared to stage interface method. However, pressure has maximum two percent error according to the installation angles while pressure is almost constant for the stage interface method. And stage interface method can relatively well predict the blower performance. Detailed internal flows of the centrifugal blower are compared and analyzed by numerical simulation.

Evaluation of Inflow Uniformity on the Performance of Double-Inlet Centrifugal Blower Using Optimal Design Method (양흡입 원심블로어 성능향상을 위한 입구 유동 최적화 연구)

  • Lee, Jong-Sung;Jang, Choon-Man;Jeon, Hyun-Jun
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.4
    • /
    • pp.326-333
    • /
    • 2013
  • This paper presents the performance enhancement of a double-inlet centrifugal blower by the shape optimization of an inlet duct. Two design variables, a length of anti circulation vane and an angles of inlet guide, are introduced to improve the inlet flow uniformity leading to the blower performance. Three-dimensional Navier-Stokes equations are used to analyze the blower performance and the internal flow of the blower. From the shape optimization of the inlet duct of the double-inlet centrifugal blower, the optimal positions of each design variable are determined. Throughout the analysis of sensitivity, it is found that the angle of the inlet guide is more effective than the length of the anti-circulation vane to increase flow uniformity at the outlet of the duct. Efficiency and pressure for the optimal inlet duct shape are successfully increased up to 3.55% and 3.2% compared to those of reference blower at the design flow condition, respectively. Detailed flow field inside the blower is also analyzed and compared.