DOI QR코드

DOI QR Code

Operating Characteristics of Serially Connected Centrifugal Blowers Used for Automated Vacuum Waste Collection System

생활폐기물 자동집하시설용 다단직렬연결 원심블로어 운전특성

  • Jang, Choon-Man (Environmental Engineering Research Division, Korea Institute of Construction Technology) ;
  • Lee, Jong-Sung (Environmental Engineering Research Division, Korea Institute of Construction Technology)
  • 장춘만 (한국건설기술연구원 환경연구실) ;
  • 이종성 (한국건설기술연구원 환경연구실)
  • Received : 2014.04.01
  • Accepted : 2014.05.22
  • Published : 2014.08.01

Abstract

This paper describes blower performance characteristics of a automated vacuum waste collection system. Blowers serially connected to six or seven centrifugal blowers are evaluated by experimental measurements to understand blower performances according to blower numbers operated. Two different blowers and duct diameters connected to the main blowers are considered. Data acquisition system is introduced to measure pressure and pressure difference at the main duct simultaneously, which is connected to several blowers serially. A auxiliary blower, which is installed between a filter room and an air deodorizing apparatus, is also added to simulate its performance effect on the main blower. Throughout the experimental measurements of the blower system, it is found that pressure and inlet velocity at the upstream of a blower increase 3.7 and 2.4 times separately by increasing the operating blower numbers from one to seven. It is noted that blower efficiency and pressure measured at the system vary according to the distance between a air intake and a blower system. Auxiliary blower is effective to increase blower inlet suction pressure, while total energy consumption is increased relatively.

Keywords

References

  1. Jang, C.-M., Lee, S.-Y. and Suh, S.-H., 2007, "Pressure Drop in a Circular Pipe of Waste Collection Piping System," Journal of Fluid Machinery, Vol. 10, No. 4, pp. 55-60. https://doi.org/10.5293/KFMA.2007.10.4.055
  2. Jang, C.-M., 2009, "Flow Characteristics of Piping System Having Various Shapes in Refuse Collection System," Journal of Fluid Machinery, Vol. 12, No. 3, pp. 13-18.
  3. Jang, C.-M., 2010, "Optimal Design and Operation of a Turbo Blower Used for Refuse Collection System," Journal of Fluid Machinery, Vol. 13, No. 5, pp. 58-63. https://doi.org/10.5293/KFMA.2010.13.5.058
  4. Bayomi, N. N., Abdel Hafiz, A., and Osman, A. M, 2006, "Effect of Inlet Straighteners on Centrifugal Fan Performance," Energy Conversion & Management, Vol. 47, pp. 3307-3318. https://doi.org/10.1016/j.enconman.2006.01.003
  5. Lee, J.-S., and Jang, C.-M., 2012, "Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower,", Journal of Trans. of Korean Hydrogen and New Energy Society, Vol. 23, No. 6, pp. 688-695. https://doi.org/10.7316/KHNES.2012.23.6.688
  6. Cesar, F., Felip, M., Carles, M. and Francina, S.-M. 2013, "Modeling Energy Consumption in Automated Vacuum Waste Collection Systems," Environmental Modelling & Software, http://dx.doi.org/10.1016/j.envsoft.2013.11.013.
  7. Ong, H. L., Goh, T. N., Poh, K. L. and Lim, C. C., 1990, "A Computerized Vehicle Routing System for Refuse Collection," Adv. Eng. Software, Vol. 12, No. 2, pp. 54-58. https://doi.org/10.1016/0141-1195(90)90019-3
  8. Basic Design Report of Automated Vacuum Waste Collection System at Incheon Cheongra. 2007.

Cited by

  1. Management of Automated Vacuum Waste Collection Systems in Suburban Apartment Complexes vol.38, pp.2, 2016, https://doi.org/10.4491/KSEE.2016.38.2.56
  2. Resident's Assessment of Automated Vacuum Waste Collection System in New Public Housing Estates vol.38, pp.4, 2016, https://doi.org/10.4491/KSEE.2016.38.4.155
  3. 생활폐기물 자동집하시설 이송관망 성능평가 vol.18, pp.5, 2014, https://doi.org/10.5293/kfma.2015.18.5.026
  4. 디스포저에 의한 음식물류폐기물 횡지관 유동성 평가 vol.20, pp.1, 2014, https://doi.org/10.5293/kfma.2017.20.1.053