• Title/Summary/Keyword: 운행모드

Search Result 42, Processing Time 0.037 seconds

Durability Evaluation of Gangway Ring for the Articulated Bogie of High speed Railway Vehicle (고속철도차량 관절대차 갱웨이 링의 내구성 평가)

  • Kang, Gil-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.66-72
    • /
    • 2019
  • To improve ride quality and running stability of high speed train(HST), it is important that connection between coaches adopts the articulated bogies by using a gangway ring, unlike the conventional independent bogies assembled with car bodies. Although the gangway ring should be ensured absolute safety against passenger movement between coaches during train operation, there is still a lack of quantitative durability criteria of that. Therefore, in order to improve the passenger safety of HST, it is important to study the test requirements on durability evaluation for the ring. In this study, seven mixed loading cases were derived from the triaxial loading(vertical/lateral/longitudinal) modes. The safety factor of each component is at least 2.4 or more from the results of the finite element analysis. In addition, fatigue safety was evaluated through durability analysis from the viewpoint of strain-life design. Durability tests for the gangway ring carried out a total of 10 million cycles in 4 phases load conditions. After the durability test, the defect of each component was investigated using nondestructive testing techniques.

A Study on the Selection of Train Operationg Mode Minimizing the Running Energy Consumption (전동열차 운행에너지를 최소화 하는 운전모드 결정)

  • Kim, Yong-Hyun;Kim, Dong-Hwan;Kim, Chi-Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.119-124
    • /
    • 2005
  • Decision of operation performance mode to minimize the energy consumption of urban rail vehicle. This paper analyses how much acceleration and deceleration of urban rail vehicle should be applied andhow to choose an operation mode to minimize energy consumption when train runs between station within the fixed operation time. The decided operation pattern satisfying the minimum energy consumption becomes a target trajectory and a basis for the controller design criteria. To make this goal it grasps the characteristics of urban rail vehicle, realize operation energy model of urban rail vehicle and verify the accuracy of embodied model the Matlab simulation with the same operation result of real route. It searches for operation pattern to minimize operation energy by changing the acceleration and deceleration on the imaginative route and proposes operation pattern minimizing energy consumption by applying real operation data between Dolgogee-Sukgye section of Seoul Metropolitan Subway Line 6.

  • PDF

ArcSAR System Design and Manufacturing (ArcSAR 시스템 설계 및 제작)

  • Cho, Seong-Jun;Lee, Hoon-Yol;Kim, Kwang-Eun;Lee, Jae-Hee;Sung, Nak-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.78-81
    • /
    • 2009
  • 레일형 GB-SAR의 단점을 극복하고자 차량에 원형레일을 탑재하여 신속한 기동을 확보하고 합성구경의 길이를 늘리며 영상영역을 확장한 ArcSAR를 세계 최초로 설계하고 시작품을 제작하였다. ArcSAR의 핵심기술이라고 할 수 있는 원형레일은 알루미늄 프로파일로 제작한 회전디스크, 곡선가이드, 리니어 가이드로 구성되며, 서보모터를 이용하여 구동된다. 회전디스크의 지름은 2.1 m 이며, 회전 디스크 위에 장착된 곡선 가이드를 따라 안테나가 탑재된 리니어 가이드가 이동하며 정밀한 원형 운행을 하게 된다. 리니어 가이드는 슬라이드식으로 제작되어 최대 3 m 까지 확장이 가능하여 스폿 모드 측정시 6 m 길이의 레일에서의 자료 획득과 유사한 결과를 얻게 된다. SAR 측정 장비는 회전디스크 위에 장착되어 전원을 제외한 별도의 슬립링을 사용을 자제하였다. 레일의 구동과 자료의 획득은 LabVIEW 기반의 통합 제어측정 소프트웨어를 통해 구현하였으며, 실내 실험 및 현장적용 실험을 통해 가능성을 확인하였다.

  • PDF

전기철도차량 전력변환장치 성능시험 기술

  • Kim, Myeong-Ryong;Ryu, Jun-Hyeong
    • KIPE Magazine
    • /
    • v.14 no.5
    • /
    • pp.36-41
    • /
    • 2009
  • 전기철도차량에는 대용량 추진제어 컨버터/인버터부터 소용량 스위칭 모드 전원장치에 이르기까지 철도차량의 운행에 필요한 각종 동력 및 전력을 공급하기 위한 여러 가지 형태의 전력변환장치가 사용되고 있다. 그 중 가장 대표적인 전력변환장치가 추진제어인버터와 보조전원장치이다. 전기철도차량의 성능평가는 전력변환장치의 성능평가라 할 수 있을 정도로 많은 비중을 전력변환장치가 차지하고 있다. 한국철도기술연구원은 국토해양부로부터 지정받은 성능시험기관으로서 국내 도시철도 및 철도차량의 성능평가를 수행하고 있다. 성능시험은 차량의 제작공정에 따라 부품시험, 구성품시험, 완성차시험, 예비주행 및 본선시운전의 각 단계별로 실시하고 그 시험기준으로 도시철도차량의 성능시험에관한기준 및 철도차량성능시험 시행지침이 적용된다. 성능시험기준을 근간으로 추진제어인버터와 보조전원장치의 성능시험 대한 시험항목과 시험방법에 대하여 소개한다.

A module type battery charger-discharger of easily extensible (확장성이 용이한 모듈타입 배터리 충방전기)

  • Park, Jin-Wook;Qu, Zhong-Zhi;Kwon, Soon-Jae;Kim, Young-Su;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.407-408
    • /
    • 2014
  • 최근 하이브리드 자동차, 지능형 자동차 등을 비롯한 미래형 자동차 분야와 관련된 연구 개발과 맞물려 자동차 전장 회로 시스템은 더욱 복잡해지고 있다. 자동차 전장 시스템의 경향으로 그린카를 들 수 있는데 이에 대한 하나의 방향성은 연비 개선과 최적의 운행조건을 위한 ISG System( Idle Stop & Go system )의 채택으로 가고 있는 추세이다. 여러 장점을 가진 ISG 시스템이지만 시동 모드 시 많은 양의 전류가 순간적으로 흘러가 일순간 전압강하 발생과 높은 스위칭 주파수에 의한 표피효과가 일어난다. 이를 제어하는 기술로 전장회로상의 DC/DC 컨버터 기술이 핵심이라 할 수 있다. 이에 따라 본 논문에서는 확장성이 용이한 고효율 DC/DC 컨버터를 제안하고 모의 실험과 실제 실험을 통해 검토한다.

  • PDF

Evaluation of the Impact of Fuel Economy by Each of Driving Modes for Medium-Size Low-Floor Bus (중형저상버스의 개별주행모드에 따른 연료소비율 평가)

  • Jung, Jae-wook;Ro, Yun-sik;Ahn, Byong-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.133-140
    • /
    • 2016
  • The Ministry of Land, Infrastructure and Transport has introduced low-floor buses, which are convenient for passengers getting on and off the bus and for the handicapped. The standard bus model is 11 m long and uses compressed natural gas (CNG). However, this model has drawbacks in narrow rural road conditions such as those in farming and fishing villages and mountainous areas, as well as difficulty in refueling since CNG facilities are not readily available. In this study, running resistance values were obtained by coasting performance tests on actual roads using a Tata Daewoo LF-40 model with three different weight conditions: curb vehicle weight (CVW), half vehicle weight (HVW), and gross vehicle weight (GVW).The test methods include WHVC, NIER-06, and constant-speed driving at 60 km/h. These tests were used to measure the fuel economy of vehicles other than the target vehicles to obtain the combined fuel economy. The energy efficiency was highest in the case of CVW. In the WHVC mode, the fuel consumption rates of HVW and GVW were typically 3.5% and 12% higher than that of CVW, respectively. In constant-speed driving, the fuel efficiency of HVW was higher than that of CVW. Further research is required to analyze the exhaust gas data.

Study of the effects of injector cleaning on the exhaust gases in a common rail diesel engine (커먼레일 디젤엔진의 인젝터 클리닝이 배기가스에 미치는 영향에 관한 연구)

  • Cho, Hong-Hyun;Kim, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5980-5987
    • /
    • 2014
  • As a response to exhaust gas regulations, the electronic control system was applied to the diesel engine. The injected fuel mass and injection timing are accurately controlled using it, and the fuel efficiency and the engine output are significantly increased. In addition, the noise and the vibration of vehicles are decreased. To maintain the optimal performance of an electronic control diesel engine, it is important to control the fuel injection pressure accurately using the fuel pressure regulator. When the fuel pressure regulator is not worked normally, the failure phenomena (starting failure, staring delay, accelerated failure, engine mismatch et al.) occurred because the fuel pressure is not stabilized and controlled accurately. In this study, the effects on a fuel pressure, return fuel mass flow, and engine rotating speed according to the control rate of fuel pressure regulator were investigated to analyze the performance variation under the failure conditions of a fuel pressure regulator. As a result, when the control rate of a fuel pressure regulator decreased by 4%~6% compared to that of the standard condition, the variation of engine rotating speed and return fuel flow were increased greatly, and the abnormal condition occurred. In addition, it is possible to diagnose the failure of a fuel pressure regulator by monitoring these conditions.

Design on the interfacing between auto-pilot and water-jet drive system (Auto pilot 와 water jet drive system 간의 Interface 설계)

  • Jin, Hyong-Du;Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.535-538
    • /
    • 2009
  • Auto Pilot is the system which move automatically the vessel through locating operation mode to automatic after entering operating course using a electronic chart or plotter. And water jet is the a propulsion system that make a power to push the vessel through spouting the accelerated water which is absolbed by the hole in the bottom of vessel. The water jet receive the effect of the depth of water lowly, it's acceletion efficiency is higher under high speed and have an advantage on vibrating and floating sound, so it's demand is increasing as new propulsion system. However, the signal systems of auto Pilot and water jet are defferant, we need the system to communicate between each system. We propose the interface system which communicate between Auto pilot and water jet efficiently in this journal.

  • PDF

Transponder and Ground Station Systems for Drones

  • Kim, Ki-Su;Ha, Heon-Seong;Lee, Jong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.9-15
    • /
    • 2020
  • In this paper, we propose a case that drone (unmanned aerial vehicle), one of the representative technologies of the 4th Industrial Revolution, threatens airport safety and privacy infringement, and describes a drone control system proposal to solve the problem. Unmanned aerial vehicle (Drone) is creating a serious problem recently, In Korea, on May 21, 19, according to the Jeju Regional Aviation Administration, drones flew over Jeju Jeongseok Airfield twice in the same month, causing problems in aircraft operation. In overseas cases, two drones near the runway of Gatwick International Airport in the UK There has been a disturbance in which the takeoff and landing of the aircraft flies for a while, and various problems have occurred, such as voyeuring the private life of an individual using a drone. This paper is equipped with an Acess Point transponder mounted on a drone (unmanned aerial vehicle), and unspecified many who want to receive flight information (coordinates, altitude, and obstacles) of the drone access the drone AP, receive and receive the flight information of the drone, and receive unspecified multiple Drone AP flight information is collected and collected to provide the information of the drone currently floating on one user interface screen. In addition, an AP transponder is proposed to operate a safe drone (unmanned aerial vehicle) and the drone's flight information is transmitted., To receive and collect and collect data.

Experimental study on cooling performance characteristics of hybrid refrigeration system in a heavy duty vehicle (상용차 하이브리드 냉방시스템 냉방 성능 특성 연구)

  • Lee, Ho-Seong;Jeon, Hanbyeol;Kim, Jung-Il;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.419-425
    • /
    • 2019
  • The objective of this study was to investigate the cooling performance characteristics of a hybrid refrigeration system in a heavy duty vehicle. The tested hybrid refrigeration system had additionally an electric compressor besides the present mechanical compressor for selective use according to the operating conditions. The applied electric compressor was a scroll type and with 18.0 cc displacement. In order to analyze the performance characteristics of the hybrid refrigeration system with respect to the cooling capacity and Coefficient of Performance (COP), other components, including two different types of compressors, were installed and tested under various operating conditions such as compressor speed and air flow rate of the evaporator. When the electric compressor was operated at 4,500 rev/min, the cooling capacity was about 4.0kW and COP was 3.5. When the mechanical compressor was operated, whereas the cooling capacity was higher than the electric controlled compressor, COP was lower due to the larger displacement and higher power consumption. To analyze the hybrid system operating characteristics due to reasonable cooling capacity with electric compressor operation, the mechanical compressor and electric compressor were operated by turns every 10 minutes under certain system operating conditions. Because surge pressure occurred when both compressors were switched on, the operating strategy required some time to balance the system pressure.