• Title/Summary/Keyword: 운전 모드

Search Result 418, Processing Time 0.024 seconds

Characteristics of Braking Noise in accordance with Operating Mode of KTX High Speed Vehicle (KTX 열차 운전 모드에 따른 정차소음 특성)

  • Lee Chan-Woo;Kim Jae-Chul;Cho Jun-Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.816-822
    • /
    • 2005
  • High speed trains with maximum speed of 300km/h, named KTX, have started revenue services since April 2004. Is becoming big problem where currently the KTX train because excessive braking noise at a station platform. The KTX braking noise follows in operating mode of KTX train and important railroad station where the quality appears different, the quality against hereupon from the commerce vehicle from the research which it sees it executes and comparison to analyze.

  • PDF

Degraded Modes and Vigilance System Analysis of High-speed Trains Driving Activities (고속철 운전 활동 저하모드 및 경계시스템 분석)

  • Noh, Hee-Min;Hong, Sun-Ho;Cho, Yon-Ok
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.2035-2039
    • /
    • 2008
  • In this paper, degrades modes of high-speed trains are deduced and analyzed by using Systems engineering architecture methods for a preceding research of hazard identification and scenarios deduction of the KTX. Moreover, Vigilance System of the high-speed trains is analyzed.

  • PDF

Periodically operating absorption heat pumps (주기적으로 작동하는 흡수식 열펌프)

  • Knoche K. F
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.5
    • /
    • pp.463-476
    • /
    • 1987
  • 주기적으로 작동하는 흡수식 장치가 부착된 직접 연소식 고효율 난방기기를 특정 공간 난방 목적으로 설계하여 제작하였다. 작동 유체는 메타놀/물-리치움브로마이드이다. 네개의 구성품으로 된 이 기기에는 동작부품이 없다. 제 1 시제품의 결과와 경험에 기반을 두고 개선형 시제품을 설계, 제작하였다. 현재까지 발생기-응축기 모듈이 설치되어 보일러 운전모드 결과가 확립되어 있다. 또한 난방기기의 경제성과 작동 유체의 안정성 연구가 중요한 부수 조건을 확립하기 위하여 수행되고 있다.

  • PDF

Effect of the Composition of a Reduced Fuel on the Concentration Change of UCl3 in the Electrorefiner (금속전환체 조성의 전해정련 전해조 UCl3 농도변화에 대한 영향)

  • Paek, Seungwoo;Lee, Chang-Hwa;Lee, Sung-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.347-353
    • /
    • 2019
  • The composition of the reduced fuel produced in the electrolytic reduction process of pyroprocessing affects the concentration change of $UCl_3$, an important operating variable of the electrorefining process. In this study, we examined the concentration change of $UCl_3$ in the electrorefiner according to the content of TRU and RE elements in the reduced fuel and the concentration of $Li_2O$ introduced in the electrorefiner accompanied with the reduced fuel. Considering only the TRU and RE elements, the concentration of $UCl_3$ decreased with increasing the number of electrorefining operation batch. In order to operate one campaign (20 batches) of electrorefining process, it was found that additional injection of $UCl_3$ should be conducted more than 3 times. On the other hand, the concentration of $UCl_3$ in the electrorefiner changed significantly depending on the concentration of $Li_2O$ and, accordingly the number of operable electrorefining batches decreased rapidly, showing that the concentration of $Li_2O$ is an important operating variable in electrorefining. Therefore, the results of this study show that to maintain the concentration of $UCl_3$ in the electrorefiner, the operation mode should be set by taking into account the effect of $Li_2O$ as well as the TRU and RE elements contained in the reduced fuel.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

Aeromechanical stability analysis and control of helicopter rotor blades (헬리콥터 회전날개깃의 안정성 해석과 제어)

  • Kim, J.S.;Chattopadhyay, Aditi
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.9 no.1
    • /
    • pp.59-69
    • /
    • 2001
  • The rotor blade is modeled using a composite box beam with arbitrary wall. The active constrained damping layers are bonded to the upper and lower surfaces of the box beam to provide active and passive damping. A finite element model, based on a hybrid displacement theory, is used in the structural analysis. The theory is capable of accurately capturing the transverse shear effects in the composite primary structure, the viscoelastic and the piezoelectric layers within the ACLs. A reduced order model is derived based on the Hankel singular value. A linear quadratic Gaussian (LQG) controller is designed based on the reduced order model and the available measurement output. However, the LQG control system fails to stabilize the perturbed system although it shows good control performance at the nominal operating condition. To improve the robust stability of LQG controller, the loop transfer recovery (LTR) method is applied. Numerical results show that the proposed controller significantly improves rotor aeromechanical stability and suppresses rotor response over large variations in rotating speed by increasing lead-lag modal damping in the coupled rotor-body system.

  • PDF

GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part Ⅰ Operating Condition Optimization (GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part Ⅰ 운전조건 최적화)

  • Oh, Jeong-Seog;Kim, Min-Ki;Heo, Pil-Won;Lee, Jang-Soo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.43-50
    • /
    • 2008
  • DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

A SRF Power Flow Control Method for Grid-Connected Single-Phase Inverter Systems (단상 계통연계 인버터의 SRF 전력제어 방법)

  • Park, Han-Eol;Kim, Eun-Seok;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.129-135
    • /
    • 2010
  • It is well known that distributed generation(DG) system using renewable energy is an alternative to solve the problems which result from the exhaustion of fossil fuel and the environmental pollution. A PWM inverter is required for a power flow control in the DG systems. This paper proposes a SRF power flow control method considering grid impedance in grid-connected single-phase inverter systems. The proposed SRF power flow control method can provide a voltage-reference for the single-phase inverter even without any grid impedance estimation so that the single-phase inverter system could operate in stand-alone mode and grid-connected mode based on the known nominal value of grid impedance. Also independent controls of active and reactive power are achieved by the proposed control method. The effectiveness and the validity of the proposed control method are demonstrated through simulations. The simulation results show that the proposed control method can control properly power flow in grid-connected single-phase inverter systems.