• Title/Summary/Keyword: 운동 정확도 측정

Search Result 254, Processing Time 0.03 seconds

Pose Calibration of Inertial Measurement Units on Joint-Constrained Rigid Bodies (관절체에 고정된 관성 센서의 위치 및 자세 보정 기법)

  • Kim, Sinyoung;Kim, Hyejin;Lee, Sung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.19 no.4
    • /
    • pp.13-22
    • /
    • 2013
  • A motion capture system is widely used in movies, computer game, and computer animation industries because it allows for creating realistic human motions efficiently. The inertial motion capture system has several advantages over more popular vision-based systems in terms of the required space and cost. However, it suffers from low accuracy due to the relatively high noise levels of the inertial sensors. In particular, the accelerometer used for measuring gravity direction loses the accuracy when the sensor is moving with non-zero linear acceleration. In this paper, we propose a method to remove the linear acceleration component from the accelerometer data in order to improve the accuracy of measuring gravity direction. In addition, we develop a simple method to calibrate the joint axis of a link to which an inertial sensor belongs as well as the position of a sensor with respect to the link. The calibration enables attaching inertial sensors in an arbitrary position and orientation with respect to a link.

Comparison of Oligosaccharyltransferase Assay Methods Using a Fluorescent Peptide (형광펩타이드를 이용한 Oligosaccharyltransferase Assay 방법 연구)

  • Kim, Seong-Hun
    • Korean Journal of Microbiology
    • /
    • v.46 no.1
    • /
    • pp.96-103
    • /
    • 2010
  • Oligosaccharyltransferase (OTase) catalyzes the transfer of a lipid-linked oligosaccharide (LLO) to the nascent polypeptide. Most eukaryotes have an OTase composed of a multisubunit protein complex. However, the kinetoplastid Leishmania major and the bacterium Campylobacter jejuni have only a single subunit for OTase activity, Stt3p and PglB, respectively. In this study, a new in vitro assay for OTase was developed by using a fluorescent peptide containing N-glycosylation sequon, Asn-Xaa-Thr/Ser, where Xaa can be any amino acid residue except Pro. L. major Stt3p and C. jejuni PglB as a model OTase enzyme demonstrated the formation of glycopeptides from a fluorescent peptide through OTase activities. For separation and measurement of the glycopeptides produced by the OTases, Tricine-SDS-PAGE, a lectin column and fluorospectrophotometer, and HPLC were applied. Comparison of these assay methods for analyzing a fluorescent glycopeptide showed HPLC analysis is the best method for separation of glycopeptides and nonglycosylated peptides as well as for quantify the peptides than other methods.

Implementation of Marine Optical Sensor System Using A Line-CCD (Line-CCD를 이용한 수중광학 센서 시스템의 구현)

  • Jeong, Ui-Seok;Lee, Dong-Ho;Lee, Kyoung-Woon;Lim, A-Ram;Jeong, Jae-Wook;Park, Jung-Ho
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.244-249
    • /
    • 2010
  • We fabricated optical sensor system that take a measurement particles using a line-CCD in ocean. To measure particles, we used 680nm laser diode which is appropriate. we tested to operate optical system in water tank and ocean. It has performance that detected signal of sensors transfer microprocessor, FPGA as long as move up and down it's motion. The system algorithm also analysis output -pressure, temperature, particle numbers in depth.-For experiment, our particle sensor system has high accuracy counter. therefore, we proposed that a line-CCD is available on optical sensor system in ocean.

근육 피로도 분석시 사용되는 매개변수들간의 민감도 비교 연구

  • 정명철;김정룡
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.406-413
    • /
    • 1997
  • 근전도(EMG:Electromyogram)를 사용하여 국부 근육 피로(Localized Muscle Fatigue)를 정량화으로 분석 하기 위해 널리 이용되고 있는 AR(Autoregressive)모델의 1차 계수, RMS(Root Mean Square), ZCR(Zero Crossing Rate), MPF(Mean Power Frequency), MF(Median Frequency)를 선택하여, 근육이 발휘하는 힘과 시간의 흐름에 따라 근육 피로의 정도를 민감하게 나타내는 매개변수를 규명하였다. 피실험자 10명의 좌우 척추세움근(Erector Spinae Muscle)을 대상으로 등장수축(Sustained Isometric Contraction)조건에서 허리의 신전(Extension)운동을 실시하였다. 이때 발휘해야 하는 힘의 수준은 15%, 30%, 45%, 60%, 75% MVC 로 정하였고 각 수준마다 20초 동안 근전도를 측정하 였다. 데이터 분석은 총20초 구간의 근전도를 0.5초 간격으로 나누어 매개변수들을 각각 구하고 분석을 실시하였다. 시간의 흐름에 대한 피로도 분석 결과, AR 모델의 1차 계수와 MPF가 유의한 차이를 보였으며, 낮은 수준의 %MVC에서는 AR 계수가, 높은 수준에서는 MPF가 민감한 반응 결과를 나타냈다. 그리고 근육이 발휘하는 힘의 정도를 분석하기 위해 주로 사용되고 있는 RMS 보다는 더 AR 계수가 모든 수준에서 뚜렷하게 차이를 보인 것이 확인되었다. 따라서 AR 모델의 1차 계수가 근육의 피로 정도와 힘의 수준을 다른 매개변수에 비해 더욱 민감하게 구별함이 입증되었다. 이러한 결과는 다른 분야에서도 근육 피로를 정량적으로 측정하는데 사용될 수 있을 것으로 생각되며, 개인적 변이도를 고려한 확률 기법을 사용한다면 보다 정확한 근전도 분석이 이루어질 것으로 기대된다.있음을 알 수 있었다. 사료된다.의 결과는 자전거 에르고노미터의 결과가 트레드밀의 결과에 87.60%정도 나타났다.음을 관찰하였다. 특히 vitamin C와 E의 병용투여는 상승적으로 적용하여 간세포손상을 더욱 억제시킴을 알 수 있었다.mance and on TFP(Total Factor Productivity) growth which is a pure measure of firm performance. To utilize the advantage of panel data, FEM(Fixed Effect Model) and REM(Random Effect Model) were used. The empirical result shows that the entropy index as a measurement of inter-business relatedness is not significant but technological relatedness index is significant. OLS estimates on pooled data were considerably different from FEM or REM estimates on panel data. By introducing interaction effect among the three variables for business portfolio properties, we obtained three findings. First, only VI (Vertical integration) has a significant positive correlation with ROS. Second, when using TFP growth as an dependent variable, both TR(Technological Relatedness) and f[ are signif

  • PDF

Numerical Analysis of Flowfield around Multicopter for the Analysis of Air Data Sensor Installation (대기자료센서 장착위치 분석을 위한 멀티콥터 주변 유동장 수치해석)

  • Park, Young Min;Lee, Chang Ho;Lee, Yung Gyo
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.20-27
    • /
    • 2017
  • The present paper describes the flow analysis of the flows around the multicopter for the selection of optimal position of air data sensor. For the flow analysis, the commercial fluid dynamics solver, STAR-CCM+ was used with polygon mesh and k-w SST turbulence modeling options. For the simulation of each rotating 4 propellers, unstructured overset mesh method was used. Hovering, forward flight, ascending and descending flight conditions are selected for the analysis and airspeed and flow angle errors were investigated using the CFD results. Through the flow field analysis, sensor location above one propeller diameter distance from the propeller rotating plane showed airspeed error less than 1m/s within the typical flight conditions of multicopter except descending.

Design of AHRS using Low-Cost MEMS IMU Sensor and Multiple Filters (저가형 MEMS IMU센서와 다중필터를 활용한 AHRS 설계)

  • Jang, Woojin;Park, Chansik
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.1
    • /
    • pp.177-186
    • /
    • 2017
  • Recently, Autonomous vehicles are getting hot attention. Amazon, the biggest online shopping service provider is developing a delivery system that uses drones. This kinds of platforms are need accurate attitude information for navigation. In this paper, a structure design of AHRS using low-cost inertia sensor is proposed. To estimate attitudes a Kalman filter which uses a quaternion based dynamic model, bias-removed measurements from MEMS Gyro, raw measurements from MEMS accelerometer and magnetometer, is designed. To remove bias from MEMS Gyro, an additional Kalman filter which uses raw Gyro measurements and attitude estimates, is designed. The performance of implemented AHRS is compared with high price off-the-shelf 3DM-GX3-25 AHRS from Microstrain. The Gyro bias was estimated within 0.0001[deg/s]. And from the estimated attitude, roll and pitch angle error is smaller than 0.2 and 0.3 degree. Yaw angle error is smaller than 6 degree.

Voice onset time in children with bilateral cochlear implants (양측 인공와우이식 아동의 성대진동시작시간 특성)

  • Jeon, Yesol;Lee, Youngmee
    • Phonetics and Speech Sciences
    • /
    • v.14 no.2
    • /
    • pp.77-86
    • /
    • 2022
  • This study aimed to investigate the voice onset time (VOT) of plosives in the VCV syllables by the place of articulation and phonation type spoken by children with bilateral cochlear implants (CIs) in comparison with children with typical hearing (TH). In all, 15 children with bilateral CIs and 15 children with TH participated in this study, aged between 5 to 10 years. All children produced 9 VCV syllables and their VOT were analyzed by the Praat software. There was no significant difference in mean VOT between children with bilateral CIs and children with TH. However, there was a significant difference in mean VOT by the place of articulation, such that the VOT for velars were longer than those for bilabials and alveolars. Additionally, there was a significant difference in mean VOT by the phonation type, such that the VOT of aspirated consonants were longer than those of lenis and fortis consonants. The results of this study suggest that children with bilateral CIs can distinguish the acoustic properties of plosive consonants and control the speech timing between the structures of the larynx and the oral cavity at a similar level as children with TH.

Multi-Objective Onboard Measurement from the Viewpoint of Safety and Efficiency (안전성 및 효율성 관점에서의 다목적 실선 실험)

  • Sang-Won Lee;Kenji Sasa;Ik-Soon Cho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.116-118
    • /
    • 2023
  • In recent years, the need for economical and sustainable ship routing has emerged due to the enforced regulations on environmental issues. Despite the development of weather forecasting technology, maritime accidents by rough waves have continued to occur due to incorrect weather forecasts. In this study, onboard measurements are conducted to observe the acutal situation on merchant ships in operation encountering rough waves. The types of measured data include information related to navigation (Ship's position, speed, bearing, rudder angle) and engine (engine revolutions, power, shaft thrust, fuel consumption), weather conditions (wind, waves), and ship motions (roll, pitch, and yaw). These ship experiments was conducted to 28,000 DWT bulk carrier, 63,000 DWT bulk carrier, 20,000 TEU container ship, and 12,000 TEU container ship. The actual ship experiment of each ship is intended to acquire various types of data and utilize them for multi-objective studies related to ship operation. Additionally, in order to confirm the sea conditions, the directional wave spectrum was reproduced using a wave simulation model. Through data collection from ship experiments and wave simulations, various studies could be proceeding such as the measurement for accurate wave information by marine radar and analysis for cargo collapse accidents. In addition, it is expected to be utilized in various themes from the perspective of safety and efficiency in ship operation.

  • PDF

Strength Evaluation of Sin91e-Radius Total Knee Replacement (TKR) (인공무릎관절의 단축법위 회전시 근력정가)

  • Wan, Jin-Young;Sub, Kwak-Yi
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.484-489
    • /
    • 2004
  • Artificial joint replacement is one of the major surgical advances of the 21th century. The primary purpose of a TKA (Total Knee Arthroplasty) is to restore normal knee Auction. Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from a chair or climbing stairs;(b) allow the same range of motion as an complete knee; and (c) provide adequate knee joint stability. Four individuals (2 peoples after surgery one year and 2 peoples after surgery three years) participated in this study. All they were prescreened for health and functional status by the same surgeon who performed the operations. Two days of accommodation practice occurred prior to the actual strength testing. The isometric strength (KIN-COM III) of the quadriceps and hamstring were measured at 60$^\circ$ and 30$^\circ$ of knee flexion, respectively. During isokinetic concentric testing, the range of motion was between 10$^\circ$ to 80$^\circ$ of knee flexion (stand-to-sit) and extension (sit-to-stand). for a given test, the trial exhibiting maximum torque was analyzed. A 16-channel MYOPACTM EMG system (Run Technologies, Inc.) was used to collect the differential input surface electromyographic (EMG) signals of the vastus medialis (VM), vastus lateralis(VL), rectus femoris (RF) during sit-to-stand and stand-to-sit tests. Disposable electrodes (Blue SensorTM, Medicotest, Inc.) were used to collect the EMG signals. The results were as follows; 1. Less maximum concentric (16% and 21% less for 1 yew man and 3 years mm, respectively) and isometric (12% and 29%, respectively) quadriceps torque for both participants. 2.14% less maximum hamstrings concentric torque for 1 year man but 16% greater torque for 3 years mm. However, 1 year man had similar hamstring isometric peak torque for both knees. 3. Less quadriceps co-contraction by 1 year man except for the VM at 10$^\circ$-20$^\circ$ and 30$^\circ$-50$^\circ$ range of knee flexion.

Development of u-Health Care System for Dementia Patients (치매환자를 위한 u-Health Care 시스템 개발)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1106-1113
    • /
    • 2013
  • For patients who have senile mental disorder such as dementia, quantity of excercise and amount of sunlight are important clue for dose and the treatment. Therefore, monitoring health information of daily life is necessary for patients' safety and healthy life. Portable & wearable sensor device and server configuration monitoring data are needed to provide these services for patients. Watch-type device(smart watch) which patients wear and server system are developed in this paper. Smart watch developed includes GPS, accelerometer and illumination sensor, and can obtain real time health information by measuring the position of patients, quantity of exercise and amount of sunlight. Server system includes the sensor data analysis algorithm and web server that doctor and protector can monitor through sensor data acquired from smart watch. The proposed data analysis algorithm acquires quantity of exercise information and detects step count in patients' motion acquired from acceleration sensor and to verify this, the three cases with fast pace, slow pace, and walking pace show 96% of the experimental result. If developed u-Healthcare System for dementia patients is applied, more high-quality medical service can be provided to patients.