• Title/Summary/Keyword: 운동 정확도 측정

Search Result 254, Processing Time 0.025 seconds

Physical Examinations of Rotator Cuff Tear (회전근 개 파열의 이학적 검사)

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Successful treatment of any pathological condition of the shoulder requires an accurate diagnosis. Physical examination represents an integral part of the assessment of shoulder disorders. Pain, loss of strength, decreased range of motion, and instability are the most common symptoms caused by a great variety of different shoulder pathologies. Therefore, a sophisticated clinical approach to the patient with shoulder pathology is essential. A standardized evaluation including a variety of diagnostic tests and clinical assessments improves the diagnostic accuracy by specifically examining one component of the shoulder complex. In most cases a careful physical examination will establish or suggest a diagnosis and special investigative techniques such as imaging procedures can be applied more selectively for confirmation or further evaluation of the pathological entity.

A Study for brake distance according to a car and rail conditions (차량과 레일 조건에 따른 제동거리에 관한 고찰)

  • Jeon, Woon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1943-1952
    • /
    • 2011
  • Rail vehicle brakes partly or completely transform the kinetic energy of moving vehicles into other forms of energy, in order to reduce the speed, and if necessary to bring them to a halt. To fulfil these requirements, the effect of a certain brake force is necessary and especially it is considered that the brake force is a important device to rail vehicles as a mass transit. The brake distance is a criterion for measuring brake force. The brake force is measured via dozens of brake distance test before its service operation. The brake distance is influenced by cars and rail conditions; weight of cars, speed on the verge of braking, temperature of brake disk and condition of the upper side of rail, etc. Therefore we will study how the these factors impact with the brake distance via a real test results.

  • PDF

A Study on Linear Energy Transfer and Specific Primary lonizaton for Charged Particles Incident on Water (대전 입자들의 초기 이온화비에 관한 연구 I)

  • 남궁미선;김부길;김정홍
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.39-47
    • /
    • 1995
  • In order to accurate treat damage induced by ionizing radiation in biological system on the cellular or subcellular level with physical parameters characterising the radiation, specific primary ionization (SPI) is introduced as the parameter which does not suffer from limitation of linear energy transfer (LET). In this present study, we calculate specitic primayt ionization with total ionization cross section (TICS) of electrons, protons and alppa particles incident on water. The used energy ranges cover those that have been freqently used in radiobioligical experiments. For electrons above 1 keV, we have relativistic corrections and also compare the results with other data. For electrons energies below 100keV, our results are in excellent agreement with theoretical calculations published recently by (perris and zarris 1987). These results may be easily applied by the interested radiobiogists.

  • PDF

Target Tracking Using Image Features in a Cluttered Environment (클러터환경에서 영상특징을 이용한 표적 추적)

  • Jung, Young-Hun;Kwak, Dong-Min;Kim, Do-Jong;Ko, Jung-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.209-216
    • /
    • 2012
  • In this paper, we propose a novel tracking method which uses image features consisted of the area, average intensity, aspect ratio of a target image for the real-time IR surveillance system. The image features of the ground target can be modeled as a random process with exponential autocorrelation function mathematically. Finally, we derived a discrete target dynamic equation including kinematic states and geometric states of the target. Simulation results shows that the performance of the proposed method is better than that of the previous tracking method.

Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging (Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Park, Soon-Ah
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.475-483
    • /
    • 1999
  • Purpose: Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to Prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Materials and Methods: Seventeen patients (M:F: 12:5, mean age; $50.4{\pm}17.5$ years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: $197{\pm}81$ days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. Results: All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern was 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization ($1.96{\pm}0.87$ vs $1.17{\pm}0.08$, p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization ($8.44{\pm}5.45$ vs $2.20{\pm}0.87$, p<0.05). Conclusion: In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy.

  • PDF

Effect of Occlusal Stabilization Appliance on Driving Distance in Golf (교합안정장치가 전문골프선수들의 드라이버 비거리에 미치는 영향)

  • Kwon, Tae-Hoon;Shin, Sang-Wan;Ryu, Jae-Jun;Lee, Richard Sung-Bok;Ahn, Su-Jin;Choi, Yeo-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.157-168
    • /
    • 2010
  • Many athletes have been using occlusal stabilization appliances to improve their performance. Few studies have examined the benefits of such an appliance in golf. We determined the effect of such appliances on the masticatory muscle activities and driving distances of professional golf players. The appliances were customized for each player and adjusted using a computerized device. The electromyographic muscle activities and driving distances with and without the appliance were measured and compared using the K7 Analyzer and the GolfAchiever II assembly. A paired t-test was used for statistical analysis. The muscle activities of the temporo-frontal and masseter muscles with the appliance were significantly more stable than those without the appliance, and the driving distances with the appliance were significantly different from those without it. Although there were intra-individual differences, professional golf players with temporomandibular disorders showed a greater improvement in performance.

Effects of Balletfit on the Body Shape (발레핏(Balletfit)프로그램이 체형 변화에 미치는 효과 연구)

  • LEE, Jaesun
    • Trans-
    • /
    • v.4
    • /
    • pp.111-134
    • /
    • 2018
  • The purpose of this study is to understand the principles of Balletfit and its program structure and to establish Balletfit's effects on body shape change and postural correction. Interview, the most commonly used method of qualitative research, was chosen as the research method. Ten Balletfit class participants, who have attended private lessons twice per week, for three to six months period of time, were selected. These participants were chosen from participants of private lessons instead of group lessons for in-depth insights. The research was limited to a small group of participants and therefore, it is difficult to standardize the result. Also, because this study is based on the opinions of the participants, not by a posture measuring device, the accuracy of the result is limited as well. The followings are the conclusion of this research. First, the participation motive was either internet research or acquaintance's recommendation. Secondly, the effort to change the body shape. After experiencing Balletfit classes, the participants became aware of their body and made an effort to recover their posture by holding the stomach tight and sitting up correctly. Thirdly, their posture became ideal. Most participants became aware of what an ideal posture is and as their body became ideal, the participants also recovered their health by becoming aware of their inner and outer body. Lastly, they tend to prefer beautiful body line. After the experience, all participants became interested in the body line and preferred to build a beautiful body line with correct postures. The most significant effect of Balletfit was the body line. Therefore, the experience of Balletfit develops the inner and outer body awareness and also can be consider to effect the change of the body shape. Balletfit will become a satisfying exercise for modern people, who desire a beautiful, healthy body.

  • PDF

Differences in Ability to Predict the Success of Motor Action According to Dance Expertise - Focusing on Pirouette En Dehors (무용 숙련성에 따른 동작결과예측 능력의 차이: 삐루엣 앙 디올 동작을 중심으로)

  • Han, Siwan;Ryu, Je-Kwang;Yi, Woojong;Yang, Jonghyun
    • Korean Journal of Cognitive Science
    • /
    • v.29 no.2
    • /
    • pp.121-135
    • /
    • 2018
  • Dancers' motions are perceived by observers through visual processes with visual information forming the basis for the observers' appreciation and evaluation of the dancers' motions. There have been many discussions as to whether or not observers' personal athletic capabilities form an essential basis for accurate assessment of the motions of others but, so far, no valid conclusions have been reached. The purpose of this study is to investigate how the ability to predict motions of others varies depending on the athletic expertise of the observers. Participants of this research were ballet dancers of varying athletic expertise. Twenty seven participants were divided into three groups with nine in each: beginners, intermediate experts and experts. The participants watched the same dance video and then evaluated whether the motion would be successful or not. The movement related visual information required to evaluate the success of the motion was systematically adjusted by controlling the length of the video. Using the temporal occlusion method, this study measured the response accuracy of the participants by category of expertise. Under the circumstance with insufficient visual information to utilize, the experts showed higher rates of correct response than the intermediate experts and the beginners. The beginners showed higher rates of wrong response than the experts and the intermediate experts. These results showed that the ability to predict success or failure of a dance motion varied depending on motion expertise of the observers, although they had similar level of expertise in perception. Participants considered to have high athletic expertise showed high prediction ability on the result of the motion. In addition, high expertise in perception reduced the likelihood that participants would make hasty responses under the circumstance with insufficient information and helped to reduce wrong response rate. In conclusion, this study showed that motor expertise and perceptual expertise contribute to prediction accuracy of observed motions.

Design and Analysis of Square Beam Type Piezo-electric Vibrating Gyroscope (압전세락믹을 이용한 사각보형 진동자이로의 설계, 제작 및 평가)

  • 이정훈;박규연;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.282-286
    • /
    • 1995
  • 일반적으로 관성계 내의 물체에 대한 동적특성의 파악을 위해서는 속도, 가속도 및 각속도, 각가속도에 대한 정보를 필요로 하며 자이로는 이중에서 각속도를 측정하는 장치이다. 운동하는 질량에 회전각속도가 인가될 때 발생되는 코리올리힘을 측정하여 회전각속도를 검출하는 개념의 각속도 센서인 진동자이로는 성능이 회전형 자이로에 비해 떨어지나 구조가 간단하고 소형이며 대량생산이 가능한 장점이 있다. 진동자이로의 효시로는 1950년 영국의 Sperry Gyroscope Company의 "Gyroton"이며, 전자기력을 이용한 가진과 측정이 그 특징으로서 실험실 조건에서 지구의 자전속도를 측정할 수 있었다. 그후 1960년대에 General Electric에서 "VYRO"라는 모델을 개발했는데 압전소자를 이용하여 가진과 측정을 하는 방법이 사용되었다. 1980년대에 Watson Ind., Soderkvist등은 센서자체가 압전물질로 만들어진 자이로를 실험하였고 1990년도에 들어서는 진동자이로의 원리를 마이크로 머시닝 기술과 연계시켜서 소형 경량화와 대량생산을 목표로 연구가 일부 진행되고 있다. 현재 제품화되어 실제 응용되고 있는 예로는 무라다사의 삼각프리즘 형태의 자이로, 토킨사의 원통형 자이로 등이 있으며 이러한 자이로는 캠코더 화면의 안정화 장치에 주로 사용되고 있다. 본 논문에서는 압전소자의 압전, 전왜 방정식으로 출발하여 자이로헤드의 동적 거동을 해석하였다. 진동자이로는 물체의 공진주파수에서의 진동현상을 이용하며, 두 방향의 고유진동수를 일치시켜야 하는 등의 설계조건이 있다. 이러한 조건을 만족하도록 사각보 구조를 기본으로 하여 새로운 형태의 자이로헤드를 고안하였다. 자이로헤드의 구동회로를 설계, 해석하고 각속도를 측정할 수 있는 검출회로를 설계하여 설계된 진동자이로의 동적 특성을 확인하고 보정회로를 이용하여 사용 주파수 영역을 넓혔다.이용하여 사용 주파수 영역을 넓혔다.러한 강이성들이 보장되는 제어이론들 중 H$_{\infty}$ 제어이론이 많이 연구/응용 되고 있다. 특히 공칭 플랜트 모델과 함께 사용되는 플랜트 모델과 함께 사용되는 플랜트 불확실성 모델은 직접적으로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the

  • PDF

What Effect can Simple Hand Tapping Have on the Accuracy and Fluency of Speech Production in Children With and Without Speech Sound Disorders? (단순 손동작 반복이 말소리장애 아동과 일반 아동의 말소리산출의 정확성과 유창성에 미치는 영향)

  • Shin, Yu-Na;Ha, Ji-Wan
    • Therapeutic Science for Rehabilitation
    • /
    • v.8 no.2
    • /
    • pp.67-78
    • /
    • 2019
  • Objective : The purpose of this study was to investigate the effect of hand tapping on the accuracy and the fluency of speech production in children with speech sound disorder(SSD) and their typically developing peers(TD). Methods : The study subjects were 15 SSD children and 15 TD children aged 4, 5, and 6 years of age. Subjects were asked to give a picture name without hand tapping in the first experimental condition, and with hand tapping in the second experiment condition. Results : The results showed that hand tapping significantly increased disfluency in TD, whereas in SSD. it did not affect the accuracy or fluency of speech production. In addition, TD demonstrated a significant positive correlation with the changes of accuracy and disfluency due to hand tapping, whereas SSD had no correlation. Conclusion : We discussed the possibility that hand tapping could serve as an obstacle distracting attention from SSD and TD, acting as a motor gesture to facilitate phonological processing when facing the difficulty in lexical retrieval for SSD.