• Title/Summary/Keyword: 용적

Search Result 1,624, Processing Time 0.026 seconds

Assesment of Indoor Radon Gas Concentration Change of College (대학의 실내 라돈가스 농도의 변화 평가)

  • Park, Hoon-Hee;Jeong, Euihwan;Kim, Hak-Jae;Lee, Juyoung;Lyu, Kwang Yeul
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.127-134
    • /
    • 2017
  • The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction.

Relationship between psychological stress and hippocampus volume through meta-analysis (메타분석을 통한 심리적 스트레스와 해마용적 간의 관계)

  • Jo, Min-kyung;Hong, Changhee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.227-236
    • /
    • 2018
  • This study was conducted to define hippocampal volume differences between a stress-laid group and normal individual group via meta-analysis. This investigation included studies that contained hippocampal volume measurements in association with stress from 1990 to 2016. Magnetic resonance imaging (MRI) measurements of hippocampal volumes were used to determine the mean size, standard deviation and sample size. The pooled effect size was measured by the standardized mean difference (SMD) with a 95% confidence interval. This meta-analysis included 13 studies comprising 374 stress subjects and 439 normal subjects. Eight studies targeted war-related veterans and holocaust survivors, while five targeted personal trauma associated with childhood abuse, rape, accident or financial hardship. The overall mean effect size (Hedges' g) was -0.70 (-1.04; -0.37). Overall, the SMD value was -0.70, with a moderate effect size, but high heterogeneity. Depending on the characteristics of the stressor, studies were divided by subgroups of war-related veterans and subjects with personal trauma and then analyzed again. In the war-related subgroup, the Hedges' g was -0.47 (-0.78; -0.16), while in the personal stressor-related subgroup it was -0.91 (-1.57; -0.26). These results indicate that there was a significant negative correlation between psychological stress and hippocampal volume.

Analysis of the cause of dose delivery errors due to changes in abdominal gas volume during MRgART pancreatic cancer (췌장암 MRgART시 복부가스용적 변화에 의한 선량전달오류 원인 분석)

  • Ha, Min Yong;Son, Sang Jun;Kim, Chan Yong;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.73-83
    • /
    • 2020
  • Purpose: The purpose of this study is to confirm the matching of the electron density between tissue and gas due to variation of abdominal gas volume in MRgART (Magnetic Resonance-guided Adaptive Radiation Therapy) for pancreatic cancer patients, and to confirm the effect on the dose change and treatment time. Materials and Methods: We compared the PTV and OAR doses of the initial plan and the AGC(Abdominal gas correction) plans to one pancreatic cancer patient who treated with MRgART using the ViewRay MRIdian System (Viewray, USA) at this clinic. In the 4fx AGC plans, Beam ON(%) according to the patient's motion error was checked to confirm the effect of abdominal gas volume on treatment time. Results: Comparing the Initial plan with the average value of AGC plan, the dose difference was -7 to 0.1% in OAR and decreased by 0.16% on average, and in PTV, the dose decreased by 4.5% to 5.5% and decreased by 5.1% on average. In Adaptive treatment, as the abdominal gas volume increased, the Beam ON(%) decreased. Conclusion: Abdominal gas volume variation causes dose change due to inaccurate electron density matching between tissue and gas. In addition, if the abdominal gas volume increases, the Beam ON(%) decreases, and the treatment time may increase due to the motion error of the patient. Therefore, in MRgART, it is necessary to check the electron density matching and minimize the variability of the abdominal gas.

Effect of Posture on the Distribution of Pulmonary Ventilation in Patients with Increased Closing volume (폐쇄용적(Closing Volume)이 증가된 만성 폐질환 환자에서 체위에 따른 폐환기량의 변화)

  • Kim, Young-Tae;Kim, Mee-Kyung;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Ryu, Jin-Sook;Lee, Myung-Hae;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.631-637
    • /
    • 1993
  • Background: In normal adults, ventilation is uneven and greater in the base than the apex of the lung in tidal volume breathing. However infants have fragile chest wall and reduced elastic recoil, resulting in easy closure of peripheral airways especially in the dependent portion of the lung. So ventilation in infants is greater in the apex than the base of the lung. We assumed that in adults whose closing volume is increased, dependent portion could be easily collapsed during tidal breathing and ventilation could be greater in the uppear than than the lower portion of the lung. Methods: We measured spirometry and closing volume(CV) in normal controls and in patients with chronic lung disease. Also we measured fractional distribution of ventilation at supine, left lateral and right lateral decubitus with $^{133}Xe$ ventilation scan in normal controls, patients with normal closing volume and patients with increased closing volume. Results: The subjects consisted of 7 normal controls(mean $age{\pm}SD$, $62.9{\pm}6.1$ years). 6 patients with normal CV($62.8{\pm}8.2$ years) and 7 patients with increased CV($63.0{\pm}15.3$ years). 1) Normal controls have mean(${\pm}SD$) FVC $104{\pm}11%$ of predicted value, $FEV_1\;120{\pm}16%,\;FEV_1/FVC\;112{\pm}5%$ and CV $86.9{\pm}12.5%$. Patients with normal CV have FVC $62{\pm}11%,\;FEV_1\;54{\pm}17%,\;FEV_1/FVC\;84{\pm}23%$ and CV $92.6{\pm}15.5%$. Patients with increased CV, have FVC $53{\pm}9%,\;FEV_1\;38{\pm}13,\;FEV_1/FVC\;69{\pm}16%$ and CV $176.1{\pm}36.6%$, CV was significantly different between two patient groups(p<0.02) 2). In normal controls mean fractional ventilation to left lung was $48.1{\pm}5.3%$ at supine, $54.1{\pm}9.8%$ at dependent and $40.9{\pm}6.5%$ at left uppermost position. In patients with normal CV mean fractional ventilation to left lung was $44.6{\pm}2.1%$ at supine, $59.7{\pm}5.6%$ at left dependent and $31.7{\pm}8.3%$ at left uppermost position. In patients with increased CV mean fractional ventilation to left lung was $48.7{\pm}4.5%$ at supine, $41.7{\pm}6.6%$ at left dependent and $60.9{\pm}15.7%$ at left uppermost position. In normal controls and patients with normal CV, ventilation to left lung at left dependent position tends to be higher than that at supine position but without statisitical significance and it was significantly lower at left uppermost than at left lung dependent position. In patients with increased CV, ventilation to left at left dependent position tends to be higher than that at supine position but without significance and it was significantly higher at left uppermost than that at left dependent position. Conclusion: These data suggest that in patients with increased CV ventilation to one side of lung could be higher at uppermost than at dependent position on lateral decubitus during tidal breathing and this fact should be taken into account in positioning of patients with unilateral lung disease.

  • PDF

무주택 우선공급 75% · 용적률 169%의 저밀도 전원도시

  • Kim, So-Jin
    • 주택과사람들
    • /
    • s.193
    • /
    • pp.64-65
    • /
    • 2006
  • 부산 최대 규모의 생태 신도시로 조성되는 정관신도시의 분양이 6월에 실시된다. 정관신도시는 녹지율 25%, 용적률 169%의 친환경 생태 도시로 만들어질 예정이어서 수요자들의 눈길을 끌고 있다. 정관신도시의 개발 방향과 업체별 분양 규모, 수요자들의 청약 전략에 대해 알아보자.

  • PDF

A dosimetric evaluation of volumetric modulated arc therapy, intensity modulated radiation therapy, and three-dimensional conformal radiation therapy for the lower extremity soft tissue sarcoma (하지 연부조직육종을 위한 방사선치료기술 별 선량평가 연구)

  • Lee, SolMin;Song, Seongchan;Hyun, Sung Eun;Park, Heung Deuk;Lee, Jaegi;Kim, Young Suk;Kim, Gwi Eon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • A dosimetric evaluation of volumetric modulated arc therapy, intensity modulated radiation therapy, and three-dimensional conformal radiation therapy for the lower extremity soft tissue sarcoma For the lower extremity soft tissue sarcoma, volumetric modulated arc therapy, intensity modulated radiation therapy, and three-dimensional conformal radiation therapy were evaluated to compare these three treatment planning technique. The mean doses to the planning target volume and the femur were calculated to evaluate target coverage and the risk of bone fracture during radiation therapy. Volumetric modulated arc therapy can reduce the dose to the femur without compromising target coverage and reduce the treatment time compared with intensity modulated radiation therapy.

  • PDF

Comparison of Regional Myocardial Perfusion, Left Ventricular Volume and Ejection Fraction between 8- and 16-Frame Gated SPECT (8-단위영상과 16-단위영상으로 얻은 게이트 심근관류 스펙트에서 국소 심근관류, 좌심실 용적과 구혈률의 비교)

  • Lee, Sang-Woo;Lee, Jae-Tae;Bae, Jin-Ho;Jeong, Shin-Young;Chun, Kyung-Ah;Ha, Jeoung-Hee;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.269-277
    • /
    • 2003
  • 목적: 게이트 심근관류 스펙트는 심근의 관류와 좌심실 기능을 동시에 평가할 수 있는 유용한 방법이다. 현재, 게이트 영상 획득시 8 단위영상이 널리 사용되지만, 아직 가장 적절한 단위영상의 수에 대해서는 논의의 여지가 있다. 본 연구는 동일한 환자에서 8 단위영상과 16 단위영상으로 게이트 심근관류 스펙트를 2회 연속적으로 시행하여 국소적 심근관류, 좌심실 용적과 구혈률등을 비교하였다. 대상 및 방법: 42명(평균 연령: 55세, 남: 녀=26: 16)의 관상동맥 질환이 의심되거나 알려진 환자를 대상으로 안정시 Tc-99m MIBI를 이용한 게이트 스펙트를 8 단위영상과 16 단위영상으로 2회 연속하여 시행하였다. 좌심실의 확장기말 용적, 수축기말 용적과 구혈률을 각각 얻었으며 확장기말의 단층영상을 18 분절로 나누고 각 분절마다 심근의 관류정도를 4등급으로 나누어 국소적 심근관류를 평가하였다. 결과: 8 단위영상과 16 단위영상 게이트 스펙트에서 국소적 심근관류의 일치도는 85.7% (tau-b=0.786, p<0.001)로 우수하였다. 두 방법간에 1등급의 차이는 100 분절(13.2%), 2등급 차이는 8 분절(1.1 %)이 있었고 3등급 차이는 없었다. 좌심실의 확장기말 용적, 수축기말 용적, 구혈률은 두 방법간에 높은 상관성을 보였으며(r=0.993, 0.989, 0.935), 좌심실 구혈률은 8 단위영상을 사용할 때 평균 1.8% 낮게 측정되어 통계적인 유의성은 있었으나(p<0.05), 그 차이는 크지 않았다. 결론: 8 단위영상과 16 단위영상을 사용한 게이트 심근관류 스펙트에서 국소적 심근관류의 일치도는 우수하였으며, 좌심실의 기능적 계수의 차이도 크지 않았다. 비록 높은 단위영상을 사용했을 때 더 정확하고 자세한 정보를 얻을 수 있다 하더라도, 구혈률과 용적 등을 얻는 일상적인 임상검사에는 8 단위영상 또한 그 역할을 충분히 할 수 있을 것으로 사료된다.

Lung Volume Reduction Surgery in Patients with Severe Emphysema, 7 cases (중증 폐기종 환자에서의 폐용적 감축술, 7례)

  • Jin, Ung;Lee, Sun-Hee;Kim, Si-Hoon;Wang, Young-Pil;Cho, Kyu-Do;Park, Jae-Kil;Kwak, Moon-Sub;Kim, Se-Wha
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.543-548
    • /
    • 1999
  • Background: These days, lung volume reduction surgery (LVRS) is used as an alternative or a bridge operation to lung transplantation in treating patients with severe emphysema. The procedure can be used in patients with pulmonary nodules combined with severe emphysema. We report the results of 21 months follow up after lung volume reduction surgery in 7 cases including 2 cases of concurrent resection of pulmonary nodules. Material and Method: Seven patients with emphysema, including 2 cases of preoperatively suspected lung cancer were operated with LVRS technique between July 1996 and June 1997. Result: Postoperative mortality was observed in a case of squamous cell carcinoma in LUL with brain metastasis, detected at postoperative 13months. Average of 21months(19-25months) follow up was done for other cases without specific events. Conclusion: LVRS is a useful operation in the treatment of patients with severe emphysema, but further evaluation should be done about the long term results and precise criteria for patient selection. Simultaneous LVRS and tumor resection could be done in patients with emphysema with marginal reserve in the hope of maximizing postoperative lung functions.

  • PDF

Comparison of Doses According to Change of Bladder Volume in Treatment of Prostate Cancer (전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가)

  • Kwon, Kyung-Tae;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.415-421
    • /
    • 2017
  • In the case of radiation therapy for prostate cancer, a balloon infused with a certain amount of air through the anus is used to reduce rectal dose. Because of the reason, radiation therapy for prostate cancer has acquired CBCT for daily image induction. In order to maintain the anatomical structure most similar to the first CT taken before treatment, it is pretreated, but it can not be said to be perfectly consistent. In two actual treatment regimens, the volume of the bladder was measured as 45.82 cc and 63.43 cc, and the equivalent diameter was 4.4 cm and 4.9 cm. As a result of this study, the mean volume of the bladder was estimated to be 56.2 cc, 105.6 cc by 20 CBCT. The mean dose of CBCT was 1.74% and the mean Bladder mean dose was 96.67%. In case B, PTV mean dose was 4.31%, Bladder mean Dose was estimated to be 97.35%. The changes in the volume of the bladder resulted in changes in the dose of PTV and bladder. The correlation coefficient of bladder dose according to the change of bladder volume showed linearity of mean dose $R^2=-0.94$. The correlation coefficient of the PTV dose according to the volume change of the bladder showed linearity of mean dose $R^2=0.04$. It was found that the dose change of PTV was larger than that of bladder according to the change of bladder volume.