• Title/Summary/Keyword: 외부피폭

Search Result 97, Processing Time 0.022 seconds

Studies on the Reference Korean and Estimation of Radiation Exposure Dose - PHYSICAL STANDARD AND ESTIMATION OF INTER-EXTERNAL RADIATION EXPOSURE DOSE - (표준한국인(標準韓國人)의 최대허용(最大許容) 피폭선량(被曝線量) 설정(設定)에 관한 연구(硏究) - 체위(體位) 및 내(內).외부(外部) 피폭선량(被曝線量) 추정(推定) -)

  • Kim, Yung-J.;Lee, Kang-S.;Chun, Ki-J.;Kim, Jong-B.;Chung, Gook-H.;Kim, Sam-R.
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 1982
  • For the purpose of establishment of Reference Korean and estimation of internal and external exposure doses in the Reference Korean, we have surveyed reference values for Koreans, such as physical standards including height, weight and body surface area, food consumption rate of daily intake of radioactive substances and exposure dose from natural radiation. The results obtained are as follows: 1) The age group of the Reference Korean ranged from 20 to 30 years old in both sexes. The height, weight and surface area of the body of the Reference Korean are 167cm, 61kg and $1.67m^2$ in male and 155cm, 51kg and $1.51m^2$, respectively in female. 2) The food consumption of the Korean is 812.8g (669.6g of vegetable food and 143.2g of animal food) per capita per day. 3) Koreans are taken about 1,200 pCi of radioactive substances(${\beta}$-ray) per capita per day. 4) The external and internal radiation exposure doses of the Korean are estimated to be 127 mrem and 8 mrem per year, respectively. However, it is believed that these values will be modified upon the addition of data collection.

  • PDF

An Analysis of Carbon-14 Metabolism for Internal Dosimetry at CANDU Nuclear Power Plants (중수로 원전 종사자의 방사선량 평가를 위한 $^{14}C$ 인체대사모델 분석)

  • Kim, Hee-Geun;Lee, Hyung-Seok;Ha, Gak-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.207-213
    • /
    • 2003
  • Carbon-14 is one of the major radionuclides released by CANDU Nuclear Power Plants(NPPs). It is almost always emitted as gas through the stack. From CANDU NPPs about 95% of all carbon-14 is released as carbon dioxide. Carbon-14 is a low energy beta emitter which, therefore, gives only a small skin dose from external radiation. As carbon dioxide Is physiologically rather inert gases for man's metabolism, the inhalation dose is probably less than 1 % of the ingestion dose. But this source of carbon-14, formed in a closed, nor-oxidative environment, was subsequently released into the workplace as an insoluble particulate when these systems were opened lip for re-tubing at CANDU NPPs. As a part of the improvement of dosimetry program at Wolsong Nuclear Power Plants, the carbon-14 metabolism based on references was investigated and studied to setup the internal dosimetry program due to inhalation of carbon-14.

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

Evaluation on Safety of Two-bed Therapy Rooms (2인용 치료병실 안전성 평가)

  • Lee, Kyung-Jae;Cho, Hyun-Duck;Oh, Chang-Bum;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won;Ahn, Hee-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.75-80
    • /
    • 2011
  • Purpose: Europe and U.S use multi-bed therapy rooms. Hereupon, this study aims to examine the safety when current one-bed therapy rooms in Seoul National University Hospital is changed into two-bed ones. Materials and Methods: This study evaluated external exposure by gamma radiation emitted from other patients and internal and external exposure caused by pollutions from other patients in case that Seoul National University Hospital installs a shielding wall between beds in existing therapy rooms. Results: When internal and external exposure was evaluated to evaluate safety of two-bed hospital rooms, 'isolation amount of patients' 5mSv exposure or below is received according to the Atomic Energy Act. Conclusion: With the increasing number of patients with thyoid cancer, patients using therapy rooms are on the rise. Therefore, improving one-person therapy rooms to two-person ones in line with international trend would increase cost reduction and management efficiency, and patients' alienation and isolation can be reduced to increase healing effects.

  • PDF

A Pathway Analysis Model for Determining Acceptable Levels of Contamination of Radionuclides in Soil (토양의 방사능오염 허용기준치 설정을 위한 피폭경로모델)

  • Lee, Chang-Woo;Kim, Kug-Chan;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.67-74
    • /
    • 1990
  • A methodology for calculating acceptable levels of contamination of radionuclides in soil for unrestricted use was described. Pathways of exposure include direct radiation from ground surfaces, ingestion of contaminated food and inhalation of resuspended radionuclides. Results calculated using site-specific data for Korean environment were discussed and compared with those estimated by other guidelines.

  • PDF

Construction of MIRD-type Korean Adult Male Phantom and Calculation of Dose Conversion Coefficients for Photon (한국 성인남성 MIRD형 모의피폭체 제작 및 광자 외부피폭 선량환산인자 산출)

  • Park, Sang-Hyun;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • MIRD-type Korean adult male phantom, 'KMIRD' was constructed to calculate Korean-specific dosimetric quantities for radiation protection consideration. The external shape of KMIRD was based on national physical standard data of Korean. KMIRD has thicket trunk than MIRD5 and arm models divided from trunk. The height and weight of the KMIRD are 171 cm and 63.8 kg. ICRP23 data were referred to constitute organs and tissues of KMIRD. However nine organs were constructed based on Korean reference data provided by Radiation Health Research Institute. In the present study, the MCNPX2.3 Monte Carlo transport code was combined with KMIRD to calculate dose conversion coefficients for photon in the energy range from 0.05 to 10 MeV. The simulated irradiation geometries are broad parallel photon beams in AP, PA, LLAT and RLAT direction. Absorbed dose conversion coefficients were compared with data calculated with MIRD5, MIRD-type phantom based on ICRP23 reference man. In some organs, the discrepancies between two phantoms amount up to nearly 30%. The effective doses conversion coefficients of KMIRD are lower than those of MIRD5. The dose discrepancies between two MIRD-type phantoms ate because of physical differences between Korean and Western, also geometric differences between two phantoms. KMIRD should be revised using the full set of Korean reference data of all organs. The developed MIRD-type Korean adult male phantom can be applied to dose assessment of internal exposure.

Radiological Consequence of LOCA for a 900MWe French PWR (프랑스형 900 MWe PWR 에서 냉각재상실사고의 방사선학적 영향)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.40-47
    • /
    • 1987
  • The amount of the radionuclide release to the environment during a LOCA and its radiological consequence are assessed, for a 900MWe French PWR which is similar to the KNU 9/10, according to RFS V.1.a, in which the source term has been revised more conservatively after the TMI accident. The assessed result shows that the whole body and thyroid doses at the site boundary(500m) for 2 hours after the release are 66 mrem and 13.5 rem, respectively, and are within the corresponding limits. It is expected, however, that the thyroid dose would exceed the limit if the fraction of the organic iodine is over 10% of the iodine inventory.

  • PDF