• Title/Summary/Keyword: 외부증착

Search Result 133, Processing Time 0.028 seconds

Micromachined pH Sensor Using Open Well Structures (개방형 우물 구조를 이용한 마이크로머신형 pH 센서)

  • Kim, Heung-Rak;Kim, Young-Deog;Jeong, Woo-Cheol;Kim, Kwang-Il;Kim, Dong-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • A structure of a glass electrode-type pH sensor for measuring any concentration of $H^+$ in an aqueous solution was embodied with bulk micromachining technology. Two open well structures were formed, and a reference electrode was secured by the Ag/AgCl thin film in the sloped side of the etched structure. A sensitive membrane of an indicator electrode for generating a potential by an exchange reaction to $H^+$ was made with a glass containing Na 20% or more finely so that its thickness might be $100{\mu}m$ or so, and then it was bonded to one pyramidal structure. A liquid junction for a current path was formed by filling an agar in the anisotropically etched part of the Si wafer, which had a size of $50{\mu}m{\times}50{\mu}m$, and then bonded it to the other. After complete fabrication of each part, it was filled with a 2M KCl reference solution and encapsulated the sensor structure with a cold expoxy. The potential value of fabricated pH sensor was about 90mV/pH in the standard pH solutions.

Mesh/grid 기반 투명 전극의 구조 최적화

  • Yun, Min-Ju;Kim, Gyeong-Heon;Park, Sang-Yeong;Kim, Hui-Dong;An, Ho-Myeong;Kim, Tae-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.411-412
    • /
    • 2013
  • 최근 UV LED는 생화학 및 의료 산업에서 많은 각광을 받고 있다. 특히, 360nm 이하의 파장대를 갖는 UV LED는 치료 기술, 센서, 물이나 공기 등의 정화와 같은 목적으로 특별한 관심이 쏠리고 있다 [1]. 이러한 지속적인 연구를 통하여 현재까지 UV LED는 거대한 성장을 이루어 왔다. 하지만 이러한 노력에도 불구하고, 360 nm 이하의 UV LED는 여전히 오믹 접촉과 전류 분산이 원활하지 못하다는 문제점을 가지고 있다. 이것은 UV LED의 외부 양자 효율을 감소시키고, 더 나아가 극도로 낮은 광 추출 효율을 초래한다. 최근 이러한 문제를 해결하고자, 투명 전도성 산화물(TCO)을 금속 전극과 p-AlGaN 사이에 삽입해주는데, 현재 가장 널리 사용되는 TCO 물질은 ITO 이다 [2]. 하지만 ITO 물질은 상대적으로 작은 밴드갭(3.3~4.3 eV)과 단파장 빛이 가지는 큰 에너지로 인하여 deep-UV 영역에서는 빛이 투과하지 못하고 대부분 흡수된다 [3]. 따라서 본 연구에서는 기존의 박막형 ITO 투명 전극에 비해 투과도 손실을 최소화할 수 있는 mesh, grid 기반의 투명전극을 연구하였다. Fig. 1과 같이 $5{\mu}m$, $10{\mu}m$, $20{\mu}m$ 간격으로 이루어진 mesh, grid 구조의 투명전극을 구현하여 투과도 손실을 최소화하면서 우수한 전기적 특성을 확보하기 위한 구조 최적화 연구를 진행하였다. 본 연구를 위해 mesh, grid 구조의 ITO 전극 패턴을 photolitho 공정으로 형성하였으며, e-beam 증착법으로 60 nm 두께의 ITO 전극을 형성 후 질소 분위기/$650^{\circ}$에서 30초 동안 RTA 공정을 진행하였다. Fig. 1에서 볼 수 있듯이 mesh, grid의 간격이 증가할수록 투명 전극이 차지하는 면적이 감소하여 투과도는 향상되는 반면, 투명 전극과 p-GaN과의 접촉 면적 또한 감소하므로 오믹 특성이 저하된다. 따라서 투과도 손실을 최소화하면서 우수한 전기적 특성을 확보하기 위해 mesh는 $20{\mu}m$, grid는 $10{\mu}m$ 간격의 구조로 각각 최적화하였다. 그 결과 박막 기반의 ITO 투명전극 대비 최대 약 10% 향상된 투과도를 확보하였으며, I-V Curve 결과를 통하여 p-GaN 기판과 mesh 구조의 ITO 전극 사이에 박막 기반의 투명 전극과 비슷한 수준인 $0.35{\mu}A(@5V)$의 전기적 특성을 확보하였다. 결과적으로 mesh, grid 기반 투명전극의 구조 최적화를 통하여 p-GaN과 원활한 오믹 접촉을 형성하는 동시에 기존 박막형 ITO 투명 전극 구조보다 높은 투과도를 확보할 수 있었다.

  • PDF

3D Interactive Virtual Space System based on VRML and EAI (VRML과 EAI를 이용한 3D 상호작용 가상공간시스템)

  • 염창근;박경환
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 1998.10a
    • /
    • pp.149-154
    • /
    • 1998
  • 본 논문에서는 월드와이드웹상에서 3차원 인터페이스를 기술하는 표준 사양인 VRML과 자바의 EAI(External Authoring Interface)를 통하여 사용자 간에 발생하는 상호작용들을 동기화 시키는 방법을 소개한다. 제시한 방법에서는 별도의 독립적인 응용프로그램을 작성하거나 동기화를 위하여 확장된 VRML을 사용할 필요없이 웹브라우저와 바로 호환하여 사용할 수 있으며 기존의 방대한 웹문서와 연계가 쉬우므로 범용적인 자료구축이 가능하다. 하지만, 가장 최근의 VRML97에서조차도 VRML이 제시하는 가상공간 다중 사용자 환경의 지원은 아직 미비하다. 더 이상 단순히 3차원 월드를 탐험하는 시기는 지났으며, 같은 공간상에서 혼자가 아닌 여럿이 함께 하는 다중 사용자 환경을 제공해야 할 것이다. 이에 자바의 네트웍 기능과 가상공간의 외부에서 동적으로 월드를 제어할 수 있는 EAI를 이용하여 부족했던 다중 사용자 환경을 지원함으로써 가상 공간 시스템을 구축할 수 있다. 그러나, 가상 공간에서 일어나는 이벤트는 단지 동일 브라우저에서만 유효하기 때문에 다른 사용자에게 전달할 때는 이벤트를 원격지의 이벤트와 연동하기 위하여 다른 방법이 필요하다. 사용자 상호작용 시스템에 있어서 이러한 이벤트를 결정하는 가장 중요한 요소는 아바타의 행동양식(avatar's behavior)이라 할 수 있다. 가상 공간에서 일어나는 이벤트의 대부분이 사용자에 의해서 발생되는 것들이다. 즉, 아바타의 행위에 따라서 사용자 서로 간에 상호작용이 일어나게 되며 이들 이벤트를 서로 동기화 함으로써 실시간 3차원 상호작용 시스템을 구현한다. 이렇게 구현된 시스템을 구현한다. 이렇게 구현된 시스템은 전자 상거래, 가상 쇼핑몰, 가상 전시화, 또는 3차원 게임이나 가상교육 시스템과 같은 웹기반 응용프로그램에 사용될 수 있다.물을 보존·관리하는 것이 필요하다. 이는 도서관의 기능만으로는 감당하기 어렵기 때문에 대학정보화의 센터로서의 도서관과 공공기록물 전문 담당자로서의 대학아카이브즈가 함께 하여 대학의 공식적인 직무 관련 업무를 원활하게 지원하고, 그럼으로써 양 기관의 위상을 높이는 상승효과를 낼 수 있다.하여는, 인쇄된 일차적 정보자료의 검색방법등을 개선하고, 나아가서는 법령과 판례정보를 위한 효율적인 시스템을 구축하며, 뿐만 아니라 이용자의 요구에 충분히 대처할 수 잇는 도서관으로 변화되는 것이다. 이와 함께 가장 중요한 것은 법과대학과 사법연수원에서 법학 연구방법에 관한 강좌를 개설하여 각종 법률정보원의 활용 내지 도서관 이용방법에 관하여 교육하는 것이다.글을 연구하고, 그 결과에 의존하여서 우리의 실제의 생활에 사용하는 $\boxDr$한국어사전$\boxUl$등을 만드는 과정에서, 어떤 의미에서 실험되었다고 말할 수가 있는 언어과학의 연구의 결과에 의존하여서 수행되는 철학적인 작업이다. 여기에서는 하나의 철학적인 연구의 시작으로 받아들여지는 이 의미분석의 문제를 반성하여 본다. 것이 필요하다고 사료된다.크기에 의존하며, 또한 이러한 영향은 $(Ti_{1-x}AI_{x})N$ 피막에 존재하는 AI의 함량이 높고, 초기에 증착된 막의 업자 크기가 작을 수록 클 것으로 여겨진다. 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응

  • PDF

Growth of $ZnGa_2O_4:Mn^{2+}$ Thin Film Phosphors by RF Magnetron Sputtering (박막 형광체 $ZnGa_2O_4:Mn^{2+}$의 RF Magnetron Sputtering법을 이용한 생장)

  • Kim J.S.;Lee S.H.;Park J.H.;Park H.W.;Choi J.C.;Park H.L.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.404-409
    • /
    • 2006
  • Thin-film $ZnGa_2O_4 : Mn^{2+}$ phosphors of spinel structure were grown on quartz substrate by RF magnetron sputtering method at room temperature. As an increase of post-annealing temperatures, crystallinity, surface roughness and stoichiometry of thin films were varied. At the post-annealing temperatures of $500^{\circ}C$ and $600^{\circ}C$, the luminescence intensity was poor due to the poor crystallinity. The smallest surface roughness was observed at the sample post-annealed at $700^{\circ}C$ leading to low external extraction efficiency, and poor luminescence intensity. The highest luminescence intensity was shown at the sample post-annealed at $800^{\circ}C$. It was because both the surface roughness and crystallnity were optimized. On the other hand, at $900^{\circ}C$, the luminescence intensity was poor due to the violation of stoichiometry.

A Study on the Magnetoresistive RAM (MRAM) Characteristics of NiFeCo/Cu/Co Trilayers (NiFeCo/Cu/Co 삼층막의 자기저항 메모리 특성에 관한 연구)

  • 김형준;이병일;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.3
    • /
    • pp.152-158
    • /
    • 1997
  • NiFeCo/ Cu /Co trilayers were formed on 4$^{\circ}$ tilt-cut Si(111) substrates with a Cu(50$\AA$) underlayer and large-scaled test magnetoresistive RAM (MRAM) cells were fabricated using a conventional lithographic process. NiFeCo / Cu /Co trilayers deposited on the same templates without any applied magnetic field showed strong in plane uniaxial magnetic anisotropy and excellent magnetoresistive (MR) properties such as high MR ration and sensitivity within a low external magnetic field, which are suitable properties for a MRAM application. In order to obtain optimized MR results in NiFeCo /Cu /Co trilayers, the thickness of Cu spacer was varied. Interlayer coupling between two magnetic layers was observed and it was found that the MR properties were strongly dependent on the coupling force, especially near 20 $\AA$ of Cu spacer thickness. Test MRAM cells were fabricated using the optimized NiFeCo (60$\AA$)/ Cu (25$\AA$)/ Co (30$\AA$) trilayer thin films. With a 10 mA of sense current and 5$\times$$10^5$ of word current, 10 mV of signal output was obtained, which implies the strong potentials of NiFeCo/ Cu /Co trilayer thin films for a MRAM application.

  • PDF

The Low-field Tunnel-type Magnetoresistance Characteristics of Thin Films Deposited on Different Substrate (기판 효과에 따른 저 자장 영역에서의 자기저항 효과에 관한 연구)

  • Lee, Hi-Min;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.41-45
    • /
    • 2002
  • The low-field tunnel-type magnetoresistance (MR) properties of sol-gel derived $La_{0.7}Pb_{0.3}MnO_3(LPMO)$ thin film deposited on different substrate have been investigated. Polycrystalline thin films were fabricated by spin-coating on $SiO_2/Si(100)$ substrate and that with yttria-stabilized zirconia (YSZ) buffer layer, while c-axis-oriented thim film was grown on $LaAlO_3(001)$ (LAO) single crystal substrate. The full width half maximum (FWHM) of the rocking curve scan of LPMO/LAO film is $0.32^{\circ}$. Tunnel-type MR ratio is 0.52 % in $LPMO/SiO_2/Si$(100) film and that of $LPMO/YSZ/SiO_2/Si$(100) film is as high as 0.68 %, whereas that of LPMO/LAO(001) film is less than 0.4 % under the applied field of 500 Oe at 300 K. Well-pronounced MR hysteresis was registered with an MR peak in the vicinity of the coercive field. The low-field tunnel-type MR characteristics of thin films deposited on different substrates originates from the behavior of grain boundary properties.

Flow Rate Changes in the Heterogeneous Rectangular Microchannels with Different Hydrophilicity for the PDMS Bottom Surface (PDMS 표면특성에 따른 비균일계 마이크로채널의 유속 변화)

  • Noh, Soon-Young;Lee, Hyo-Song;Kim, Ki-Ho;Choi, Jae-Ho;Yu, Jae-Keun;Yoon, Soo-Kyung;Rhee, Young-Woo
    • Clean Technology
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • This study investigated the flow rate changes of the heterogeneous rectangular microchannels which have different hydrophilic property on the bottom surface. The heterogeneous rectangular microchannel has three native PDMS (poly-dimethyl siloxane) surfaces which were patterned by the soft lithography. PDMS bottom surface was treated by the argon plasma and coated by the allyl alcohol (99%). The channel length was 10, 20 and 30 mm and the channel width was 100, 200 and $300\;{\mu}m$, respectively. Several external voltages were applied to make the fluid flow by the electroosmosis in the microchannel. For the same electric field strength and hydrophilicity of the bottom surface, the flow rate is almost same. This result is matched to the theoretical expectation and confirms that the experimental system is reliable. With increasing the channel width, the flow rate increased for the same hydrophilicity of the bottom surface. The flow rate of the microchannel of higher hydrophilicity was larger than that of the microchannel of lower hydrophilicity. This result implies that the hydrophilicity change of the bottom surface could be applied to control the flow rate in the microchannel.

  • PDF

Hybrid Water Treatment of Carbon Ultrafiltration Membrane and Polypropylene Beads Coated with Photocatalyst: Effect of Organic Materials, Photo-oxidation, and Adsorption in Water Back-flushing (탄소 한외여과막 및 광촉매 코팅 폴리프로필렌 구의 혼성 수처리: 물 역세척 시 유기물 및 광산화, 흡착의 영향)

  • Park, Jin Yong;Jung, Chung Ho
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.359-368
    • /
    • 2012
  • For hybrid water treatment of high turbidity water, we used the hybrid module that was composed of photocatalyst packing between tubular membrane outside and module inside. Photocatalyst was PP (polypropylene) bead coated with $TiO_2$ powder by CVD (chemical vapor deposition) process. Water back-flushing of 10 sec was performed per every period of 10 min to minimize membrane fouling for modified solution was prepared with humic acid and kaolin. Resistance of membrane fouling ($R_f$) decreased as humic acid concentration changed from 10 mg/L to 2 mg/L, and finally the highest total permeate volume ($V_T$) could be obtained at 2 mg/L, which was the same with the previous results. Then, treatment efficiencies of turbidity and humic acid were above 98.9% and 88.7%, respectively. As results of treatment portions of UF, UF + $TiO_2$, and UF + $TiO_2$ + UV processes, turbidity was treated little by photocatalyst adsorption, and photo-oxidation. However, treatment portions of humic acid by adsorption and photo-oxidation were 2.5% and 12.3%, respectively. Compared with the previous results, treatment portions of humic acid by adsorption and photo-oxidation were different depending on membrane material and pore size. As simplified the process, the membrane fouling resistance after 180 minutes' operation ($R_{f,180}$) increased and the final permeate flux decreased a little.

Post-annealing Effect of Giant Magnetoresistance-Spin Valve Device for Sensor (센서용 거대자기저항 스핀밸브소자의 열처리 효과)

  • Lee, Sang-Suk;Park, Sang-Hyun;Soh, Kwang-Sup;Joo, Ho-Wan;Kim, Gi-Wang;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.172-177
    • /
    • 2007
  • In order to detect of the magnetic property in the cell unit, we studied the GMR-SV (giant magnetoresistance-spin valves) biosensor, which was depended on the micro patterned features according to two easy directions of longitudinal and transversal axes. Here, the multi layer structure was glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe. The uniaxial anisotropy direction was applied to the patterned biosensor during the deposition and vacuum post-annealing at $200^{\circ}C$ under the magnitude of 300 Oe, respectively. Considering the magnetic shape anisotropy effect, the size of micro patterned biosensor was a $2{\times}5{\mu}m^2$ after the photo lithography process. By our experimental results, we confirmed that the best condition of GMR-SV biosensor should be the same direction of the axis sensing current and the easy axis of pinned NiO/NiFe/CoFe triple layer oriented to the width direction of device, and the direction of the easy axis of free CoFe/NiFe bilayer was according to the longitudinal direction of device.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Photocatalyst and Ceramic Microfiltration: Effect of Organic Materials in Water-back-flushing (광촉매 및 세라믹 정밀여과 혼성공정에 의한 고탁도 원수의 고도정수처리: 물 역세척시 유기물의 영향)

  • Park, Jin-Yong;Lee, Gwon-Seop
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.72-83
    • /
    • 2011
  • For advanced drinking water treatment of high turbidity water, we used the hybrid module that was composed of photocatalyst packing between outside of tubular ceramic microfiltration membrane and membrane module inside. Photocatalyst was PP (polypropylene) bead coated $TiO_2$ powder by CVD (chemical vapor deposition) process. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, modified solution was prepared with humic acid and kaolin. Water-back-flushing of 10 sec was performed per every period of 10 min to minimize membrane fouling. Resistance of membrane fouling ($R_f$) decreased and J increased as concentration of humic acid changed from 10 mg/L to 2 mg/L, and finally the highest total permeate volume ($V_T$) could be obtained at 2 mg/L. Then, treatment efficiencies of turbidity and $UV_{254}$ absorbance were above 98.5% and 85.7%, respectively. As results of treatment portions by membrane filtration, photocatalyst adsorption, and photo-oxidation in MF, MF + $TiO_2$, and MF + $TiO_2$ + UV processes, turbidity was treated little by photocatalyst adsorption, and photo-oxidation. However, treatment portions of humic acid by adsorption and photo-oxidation were above 10.7 and 8.6%, respectively.