• Title/Summary/Keyword: 외기 온도

Search Result 231, Processing Time 0.031 seconds

Effects of Combination of Air Temperature and Soil Moisture Contents on Growth, Clove Initiation, Physiological Disorders, and Yield of Garlic (기온과 토양수분 함량에 따른 난지형 마늘의 생장, 인편분화, 생리장해 및 수량에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Mun, Boheum;Lee, Jin Hyoung;Lee, Hee Su;Kwon, Young Seok;Han, Ji Won;Kim, Cheol Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.191-198
    • /
    • 2018
  • The objective of this study was to determine the effects of combination of air temperature and soil water contents on growth, physiological disorder rate, and yield of garlic. This experiments has been carried out in the typical plastic house (one side open and other side installed ventilation fans) which was maintained gradient air temperature (maximum different value of air temperature : $6^{\circ}C$). The excessive irrigation (EI) set at $0.34m^3/m^3$ soil moisture contents. The significant differences found in the growth parameters of garlics as affected by air temperature and soil moisture conditions. The plant height of garlic with combination of ambient $(A)+6^{\circ}C$ and optimal irrigation (OI; set at $0.22m^3/m^3$ soil moisture contents) treatments represented 47.4 cm/plant, which was the highest among all the tested treatments. The leaf length and width showed the greatest, which were 16.1 and 2.4 cm/plant, respectively, in $A+6^{\circ}C-OI$. The physiological disorder ratio was higher as 12.9% at $A+6^{\circ}C-OI$ and was not occurred at ambient temperature with EI compared with OI treatment. The bulb and clove weight were dramatically decreased at $A+6^{\circ}C$ temperature treatment. The yields were decreased by 51% in OI at $A+6^{\circ}C$ and $A+3^{\circ}C$ temperature treatment. Those results indicated that yields were decreased and ratio of physiological disorders was increased by high temperature treatments.

Studies on the Storage of a New Rice Variety Tongil (수도신품종(水稻新品種) "통일(統一)"의 저장성연구(貯藏性硏究))

  • Han, Pan-Ju;Kim, Young-Sang;Min, Yong-Kyu
    • Korean Journal of Food Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.136-140
    • /
    • 1976
  • To investigate the preservability of Tongil, three types(rough, brown and milled rice) of Tongil and the common variety (being composed of typical varieties) in Korea were stored at a ambient and a low temperature $(15^{\circ}C)$ warehouse from April to October of each year for three years (1972-1974). The results obtained are described as follows; 1) Temperatures of atmosphere and the natural temperature warehouse changed in the same way. 2) Similar changes of relative humidity were observed in atmosphere and both warehouses. 3) Equilibrium moisture content of Tongil at $25^{\circ}C$ was 0.55 % lower in rough and brown rice. 0.33% lower in milled rice than each type of the common variety. 4) Weight loss rate in the natural temperature storage and in the low temperature storage was 1.35% and 0.74% after 6 month storage. 5) The change of fat acidity in browe rice was greater than any others (rough and milled rice). 6) Hardness of Tongil was 1.64kg higher than that of the common variety. 7) Germination rate was about the same during the low temperature storage, but that of brown of the natural temperature storage was abruptly decreased to $23%{\sim}37%$ after August. As a result, it is possible Tongil is applicable to the long-term storage of rice due to Tongil's superior preservability.

  • PDF

A Study on the Natural Evaporation Capacity of LPG Container (액화석유가스 용기의 자연 증발량에 관한 연구)

  • Jo Young-Do;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.22-29
    • /
    • 2001
  • The number of gas containers and the period of exchanging gas containers are vsy important in designing liquefied petroleum gas(LPG) supply system for small capacity domain. And also the evaluation of remaining LPG in containers to be exchanged is very useful information in commerce. However seldon has been studied on calculating method about those with respect to gas consumption pattern. In this study, a simulation method was developed to estimate the evaporation capacity of LPG container, the mass gas flow rate from LPG container, the temperature and vapor pressure of LPG, and the remained LPG at containers to be exchange by using LPG property equations, mass balance equation, and heat balance equation. The simulation results were correlated well with experimental data. The overall heat transfer coefficient from air to LPG is approximately $9{\~}13 kcal/m^2{\cdot}hr{\cdot}^{\circ}C$ and does not strongly affect on the evaporation capacity of LPG container. The mass gas flow rate from LPG container is constant when the vapor pressure of LPG is within pressure regulator's control range. While, out of range, it suddenly reduce to a evaporation rate which is balanced with heat transfer from air. The evaporation capacity of LPG container increased with surrounding temperature and the composition of propane, and decreased drastically with continuous gas consumption. The number of gas containers divided the number of houses using gas supply system was reduced by using automatic gas feeding device.

  • PDF

Analysis of Factors for Seasonal Meat Color Characteristics in Hanwoo(Korean Cattle) Beef using Decision Tree Method (의사결정나무분석기법을 이용한 계절별 한우육의 육색 특성에 미치는 요인분석)

  • Kim, Seok-Jung;Kim, Yong-Sun;Song, Young-Han;Lee, Sung-Ki
    • Journal of Animal Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.607-616
    • /
    • 2002
  • This study analyzed the effects of pH, sex, backfat thickness, ribeye area, cold carcass weight, shipping month, muscle internal temperature, average daily temperature, and average relative humidity for slaughtered Hanwoo to meat color by season. The analyses focused on interaction and each effect to meat color of the factors. For the result for analysis of multiple linear regressions, meat color values were decreased as pH increased in all meat color, and the meat color values increased as the backfat thickness was increased. As the results of the decision tree analysis by each factor, cow and steer slaughtered in spring and autumn were the highest in the lightness(L*). The redness(a*) was the cases that pH was less than 5.63 and average relative humidity was over than 71.5% for Hanwoo slaughtered in autumn. The chroma(C*) value was the highest for Hanwoo that was slaughtered in summer and autumn, the pH was less than 5.60, and the back fat thickness was over than 8 mm. The hue angle($h^0$) was shown that the muscle internal temperature was less than 4.7$^{\circ}C$ among Hanwoo which was slaughtered in spring, summer, and autumn, the pH was less than 5.66, and the back fat thickness was over than 8 mm.

Development and Validation of Inner Environment Prediction Model for Glass Greenhouse using CFD (CFD를 이용한 유리온실 내부 환경 예측 모델 개발 및 검증)

  • Jeong, In Seon;Lee, Chung Geon;Cho, La Hoon;Park, Sun Yong;Kim, Min Jun;Kim, Seok Jun;Kim, Dae Hyun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.285-292
    • /
    • 2020
  • Because the inner environment of greenhouse has a direct impact on crop production, many studies have been performed to develop technologies for controlling the environment in the greenhouse. However, it is difficult to apply the technology developed to all greenhouses because those studies were conducted through empirical experiments in specific greenhouses. It takes a lot of time and cost to develop the models that can be applicable to all greenhouse in real situation. Therefore studies are underway to solve this problem using computer-based simulation techniques. In this study, a model was developed to predict the inner environment of glass greenhouse using CFD simulation method. The developed model was validated using primary and secondary heating experiment and daytime greenhouse inner temperature data. As a result of comparing the measured and predicted value, the mean temperature and uniformity were 2.62℃ and 2.92%p higher in the predicted value, respectively. R2 was 0.9628, confirming that the measured and the predicted values showed similar tendency. In the future, the model needs to improve by applying the shape of the greenhouse and the position of the inner heat exchanger for efficient thermal energy management of the greenhouse.

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel (터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Yang-Kyun;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.743-755
    • /
    • 2018
  • Tunnel is a semi-closed structure similar to underground space where the smoke generated from fire fills the space fast while escaping from the space slow. Because of such characteristics, when the fire breaks out by traffic accident, the vehicles are jammed making it difficult for the people to evacuate from the scene as well as for the fire engine to gain access to the scene. For such reasons, tunnels are globally categorized into some disaster classes for differentiated facilities and operation approaches. In Korea, less than a 1 km-long tunnel accounts for 80.0% and such a short tunnel which is categorized into Class III is not required to have smoke control system. In this study, a full-scale fire test was conducted in a bid to apply air curtain system using heat-resistant sirocco fan to a less than 1 km-long tunnel. To that end, heat resistance test to verify the normal operation at $250^{\circ}C$ for 60 minutes was conducted. Consequently, despite of rapid rising-temperature and increasing-carbon dioxide inside the air curtain (direction of fire in tunnel), initial condition was found to have been sustained outside the air curtain (opposite direction of fire in tunnel).

Simulation and Experimental Study on an Air-Cooled $NH_3/H_2O$ Absorption Chiller (공랭형 $NH_3/H_2O$ 흡수식 냉동기의 모사 및 실험적 연구)

  • Oh Min Kyu;Kim Hyun Jun;Kim Sung Soo;Kang Yong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1028-1034
    • /
    • 2005
  • The objective of this paper is to study the effects of the cooling air mass flow rate and the heat input variation by the simulation and the experiment. An air-cooled $NH_3/H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect machine is 17.6 kW (5.0 USRT). The overall conductance (UA) of each component, the cooling capacity, coefficient of performance and each state point are measured with the variation of the cooling air mass flow rate and the heat input. It is found that the COP and cooling capacity increase and then decreases with increasing the heat input. It is also found that the COP and the cooling capacity increase and keep constant with increasing the cooling air mass flow rate. The maximum COP is estimated as 0.51 and the optimum cooling air mass flow rate is $217\;m^3/min$ from the present experiment.

Comparative Studies on Heating and Cooling Loads' of a Building Varied by Annual Weather Data (연도별 기상데이터를 활용한 건물의 냉.난방부하 특성 비교)

  • Lee, Ji-Hoon;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.265-270
    • /
    • 2011
  • The purpose of this study is to compare and analyze the differences of a building's heating and cooling loads depending on the weather variation. Followings are the results. The temperature, humidity and wind speeds of standard year are bigger than those of 2006~2009. The 2006~2009's total horizontal solar irradiance is greater than that of standard year, and the direct solar irradiance of standard year is bigger in winter and vice versa in summer. As results of simulation on heating and cooling loads, it is difficult to find out the bilateral influences between maximum thermal loads and annual's. The equivalent-time operating ratio(EOR) is defined on this study to estimate the differences between year and year, and the EOR of standard year shows low value comparing to 2006~2009 years'.

The Load Forecasting in Summer Considering Day Factor (요일 요인을 고려한 하절기 전력수요 예측)

  • Han, Jung-Hee;Baek, Jong-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2793-2800
    • /
    • 2010
  • In this paper, we propose a quadratic (nonlinear) regression model that forecasts daily demands of electric power in summer. For cost-effective production (and/or procurement) of electric power, forecasting demands of electric power with accuracy is important, especially in summer when temperature is high. In the literature, temperature and daily demands of preceding days are typically employed to construct forecasting models. While, we consider another factor, day of the week, together with temperature and daily demands of preceding days. For validating the proposed model, we demonstrate the forecasting accuracy in terms of MAPE(Mean Absolute Percentage Error) and MPE(Maximum Percentage Error) using field data from KEPCO(Korea Electric Power Corporation) in comparison with two forecasting models in the literature. When compared with the two benchmarks, the proposed forecasting model performs far better providing MAPE and MPE not exceeding 3.08% and 8.99%, respectively, in summer from 2005 to 2009.