• Title/Summary/Keyword: 외경성(畏敬性)

Search Result 101, Processing Time 0.033 seconds

Analysis of the Entry Capacity of Roundabouts (Roundabout의 용량분석)

  • 전우훈;도철웅
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.3
    • /
    • pp.59-69
    • /
    • 2003
  • Signalized intersections are widely used in urban street network. However, it was reported that a roundabout is better than a signalized intersection in terms of delay when the approaching traffic volume for each bound is low. The objective of this study is to develop entry capacity models of roundabout and establish the warrant for signalized intersection based on the delay. The entry capacity of a roundabout is determined by the circulating traffic volume and the geometric design of the roundabout such as the diameter of central island, entry lane widths, and the circulating roadway width. The traffic and geometric characteristics of four roundabouts were collected and analyzed. The study reveals that; i)among the geometric features, the diameter of central island and the circulating roadway width influence the entry capacity, and ii)even though it is difficult to compare the models of each country due to different geometric features considered in the models, the models developed in this study show higher capacity than the models from Israel or Germany. These seem to be attributed to the facts that; i)the outside diameters of the roundabouts selected in this study are larger than in the other studies, and ii)the acceptable gap in Korea is smaller than that in the other countries. In order to compare the performances of round- about and signalized intersection, the performance of roundabouts was evaluated with the SIDRA. The simulation was conducted only for the roundabouts composed of single lane. According to the result of the analysis, it may be concluded that when the approaching traffic volume for each bound is lower than 600pcph, a roundabout is better than a signalized intersection in terms of its operational performance.

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

Study of Improvement in Fatigue Life of Fuel Injection Pipe of Common Rail System (커먼레일 시스템 연료분사관의 피로수명 개선에 관한 연구)

  • Song, Se Arm;Bae, Jun Ho;Jung, Sung Yuen;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.991-998
    • /
    • 2013
  • The fuel injection pipe of a common rail system used in a clean diesel vehicle plays a role in supplying fuel from a rail to the injector of each cylinder connecting the engine under a repeated internal pressure. The fuel injection pressure is increased to over 200 MPa for satisfying EU emission standards and improving fuel efficiency, and a heading process and an autofrettage process are required for preventing folding defects and improving fatigue life. In this study, the flow stress and SN data of the material of the pipe are obtained through a tensile test and a fatigue test. The heading process for checking the folding defects of pipe ends is performed by using FEA. Furthermore, the optimal design of the autofrettage process for improving fatigue life considering not only the compressive residual stresses of the inner surface but also the tensile residual stresses of the outer surfaces of the pipe under the repeated internal pressure is performed by using FEA. To verify the process design, fatigue analysis for the autofrettaged pipe is performed.

Development of Portable-Type Electrode for the Determination of Highly Concentrated Hydrogen Peroxide (휴대용 고농도 과산화수소 측정 전극의 개발)

  • Lee, Jin Seo;Cui, Gang;Kim, Sang Jin;Cha, Geun Sig;Nam, Hakhyun;Rho, Kyung Lae;Kim, Jin Doo
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.125-129
    • /
    • 1999
  • Portable-type two electrode system for the determination of highly concentrated hydrogen peroxide (10-75%) has been studied. The electrode body was made with teflon rod (length=10 cm, diameter=1.5 cm) to withstand the highly corrosive power of hydrogen peroxide. Glass carbon rod (diameter=3 mm) was used as the working electrode and a carbon cylinder (i.d.=5 mm; o.d.=9 mm) was used as counter electrode. The applied voltage for the determination of $H_2O_2$ was 0.8 V. Diluting the highly concentrated samples taken from the industrial batch to 10% or less, it was possible to make quantitative determinations, while eliminating the interference from the stabilizer contained in the sample and preventing the surface of the electrode from oxidative corrosion. Employing hydrogen peroxide permeable membrane (teflon membrane${\leq}100{\mu}m$) for the electrode system, it was possible to measure the content of $H_2O_2$ in highly concentrated samples directly, quantitatively and reproducibly with no extra dilution step. However, it was necessary to change the internal electrolyte frequently to maintain the analytical performance of the electrode.

  • PDF

Study on Shift characteristic of Small reducer using Eccentric arm (편심캠을 이용한 소형감속기의 변속특성에 관한 연구)

  • Youm, Kwang-Wook;Ham, Seong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.609-614
    • /
    • 2017
  • In this study, a new type of eccentric cam was used for the development of a small size reducer with a two-shift reduction ratio while maintaining the same volume as the existing one-shift speed reducer. Therefore, a two-shift speed reducer was designed using the concept of a continuously variable transmission applied to automobiles. The cam was designed to have an eccentric shape with a $180^{\circ}$ phase difference to act as a tensioner to minimize slip by squeezing the V-belt connected to the deceleration pulley and the acceleration pulley, respectively. The cam was designed to have a diameter of 35mm and an outer diameter of 18mm so that the outer portion of the v-belt could contact the cam perfectly. A pulley with a diameter of 50.8mm was installed on the low speed pulley input shaft for deceleration and a pulley with a diameter of 76.2mm was provided on the output shaft. In the high-speed pulley for acceleration, a pulley with a diameter of 76.2mm is provided on the input shaft, and a pulley with a diameter of 50.8mm is provided on the output shaft. Based on the design details, the power transmission efficiency test and the heating characteristics of the transmission were tested to verify the feasibility. In addition, through validation, the suitability of the reducer was demonstrated.

Experimental analysis on the characteristics of enthalpy probe immersed in arc plasma flow (아크 플라즈마 유동에 삽입된 엔탈피 탐침의 동작특성 실험)

  • Seo, Jun-Ho;Nam, Jun-Seok;Choi, Seong-Man;Hong, Bong-Gun;Hong, Sang-Hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1240-1246
    • /
    • 2010
  • Enthalpy probe with the inner and outer diameters of 1.5 mm and 4.8 mm, respectively, is designed and used to measure the temperatures and velocities along the centerline of Ar arc plasma flow until the probe was destroyed. For this purpose, Ar arc plasma flow is generated by non-transferred type DC arc heater with the power level of 17 kW. From this experiment, it is shown that the designed enthalpy probe can measure the temperature and velocity of arc plasma flow up to 12,000 K and 600 m/s, respectively, without destroy of probe tip. In this extreme case, the arc plasma flow is calculated to transfer the heat flux of ${\sim}5{\times}10^7\;W/m^2$ to the probe based on the heat and thermal boundary equations near the forward stagnation point of a body immersed in arc plasma flow. Consequently, the designed enthalpy probe can measure the wide ranges of plasma temperatures, velocities and concentrations simultaneously, which are generated by various types of arc heaters within the heat flux ranges of $0{\sim}5{\times}10^7\;W/m^2$ on the probe tip.

Structure of Egg Envelope and Oogenesis of Kichulchoia multifasciata (Pisces, Cobitidae) (수수미꾸리 Kichulchoia multifasciata의 난자형성과정과 난막의 구조)

  • Kim, Chi-Hong;Kim, Jae-Goo;Park, Jong-Young
    • Applied Microscopy
    • /
    • v.41 no.3
    • /
    • pp.189-196
    • /
    • 2011
  • Histological study on egg envelope and oogenesis of Kichulchoia multifasciata (Pisces, Cobitidae) was carried out by light microscopes and scanning electron microscopes. Various developmental cells appeared in ovary of the specimen catched during November 2010. The cytoplasm of oogonia was acidic and many nucleoli were located at the inner side of nucleus membrane. The size of the oogonia was $103.9{\pm}24.7$ ${\mu}m$ with nucleus size $42.9{\pm}6.9$ (31.1~50.3) ${\mu}m$. Primary oocyte having $277.5{\pm}60.5$ (216.7~354.9) ${\mu}m$ in diameter began to accumulate yolk vesicles. As the developmental stages proceed, secondary oocyte grows larger to $617.6{\pm}85.1$ (503.4~723.6) ${\mu}m$, and eosinophilic yolk granules yolk granules appeared between the yolk vesicles occupying most cytoplasm, and there are some yolk mass formed already. There are some yolk mass formed already. Envelope of fertilized egg investigated by a scanning electron microscope had plenty of microvilli (2~3 ${\mu}m$ in length) over the entire egg surface and a micropyle. Especially, the microvilli surrounding the micropyle were longer than those of egg surface with $5.26{\pm}1.22$ ${\mu}m$.

Characteristics of Nitrite Scavenger Derived from Seeds of Cassia tora L. (결명자 추출물의 아질산염 소거인자의 특성)

  • Park, Yeung-Beom;Lee, Tae-Gee;Kim, Oi-Kyung;Do, Jeong-Ryong;Yeo, Saeng-Gyu;Park, Yeung-Ho;Kim, Seon-Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.124-128
    • /
    • 1995
  • The present study was conducted to elucidate nitrite scavenger derived from seeds of Cassia tora L. Methanolic extract of Cassia tora L was refractionated into ethyl ether, chloroform, ethyl acetate and water farction, and nitrite scavenging abilities of these fractions were investigated. Among these fractions, ethyl acetate fraction had the strongest nitrite scavenging ability(97%/2 mg). Therefore, to further investigate nitrite scavenger, ethyl acetate fraction was fractionated by silica gel column chromatography with a chloroform-methanol($10:0{\sim}0:10$) and then compound A and B were isolated. Compound A had a stronger nitrite-scavenging effect than compound B. Therefore the further separation of compound A was carried out by HPLC(32% acetonitrile. 1 ml/min) using ${\mu}Bondapak$C18 column$(3.9{\times}300 mm)$ and finally compound A-1 was obtained from compound A. Compound A-1 had by far nitrite-scavenging ability as compared with that of ascorbic acid. Compound A-1 was identified as $nor-rubrofusarin-6-{\beta}-mono-D-glucoside$ from the profiles of UV, IR and $^1H-NMR$.

  • PDF

Characteristics of Angiotensin-I Converting Enzyme Inhibitors Derived from Fermented Fish Product -1. Characteristics of Angiotensin-I Converting Enzyme Inhibitors Derived from Salted and Fermented Anchovy- (수산발효식품 중의 Angiotensin-I 전환효소 저해제의 특성 -1. 멸치젓갈 중의 Angiotensin-I 전환효소 저해제의 특성-)

  • KIM Seon-Bong;LEE Tae-Gee;PARK Yeung-Beom;YEUM Dong-Min;KIM Oi-Kyung;BYUN Han-Seok;PARK Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.4
    • /
    • pp.321-329
    • /
    • 1993
  • The present study was conducted to elucidate the body modulating function of fermented seafood products. Angiotensin converting enzyme (ACE) acts in blood pressure regulation, converting angiotensin I to the potent vasoconstrictor angiotensin II and inactivating the vasodilator bradykinin to raise blood pressure. Salted and fermented anchovy which is one of the traditional fermented seafood in Korea was tested for inhibitory activity against ACE. ACE inhibitory activity of salted anchovy during the period of fermentation was increased with the elapse of fermentation days until fermentation of 60 days, but thereafter decreased inversely. When the fermented product was extracted with $50\%$ ethanol, the ACE inhibitory activity was the highest. And the ACE inhibitory activity was proportion to the content of $50\%$ ethanol soluble peptide-nitrogen of the fermented product. From the profiles of gel permeation chromatography on a Bio-Gel P-2 of $50\%$ ethanol soluble fraction obtained from salted and fermented anchovy fermented for 60 days at an ambient temperature, the higher activity fractions were C'($IC_{50}=97{\mu}g\;protein/ml$) and D'($IC_{50}=65{\mu}g\;protein/ml$). Amino acid analysis showed that the large quantify of threonine, glutamic acid, lysine for C' and serine, proline for D', respectively.

  • PDF

Isolation and Characteristics of Angiotensin-I Converting Enzyme Inhibitory Activity of Peptic Hydrolyzates of Anchovy Muscle Protein (멸치육 단백질 효소가수분해물로부터 Angiotensin-I 전환효소 저해제의 분리 및 그 특성)

  • KIM Seon-Bong;LEE Tae-Gee;PARK Yeung-Beom;YEUM Dong-Min;KIM Oi-Kyung;DO Jeong-Ryong;PARK Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 1994
  • Hydrolyzates which inhibit the angiotensin-I converting enzyme(ACE) were prepared from defatted anchovy meal by pepsin. These were tested for inhibitory activity against ACE, which is one of the hypertension inducing factors. The ACE inhibitory activity of the hydrolyzates increased until 20hrs of hydrolysis had elapsed but slightly decreased after that time. And presence of $50\%$ ethanol soluble peptide-nitrogen increased slowly up to 12hrs of hydrolysis, and then mainly increased until 20hrs of hydrolysis was completed. From the profiles of gel permeation chromatography on a Bio-gel P-2 of $50\%$ ethanol soluble fraction obtained from hydrolyzate for 20hrs, the higher active fractions were 2'($IC_{50}=45\;{\mu}g\;protein/ml$) and 4'($IC_{50}=76\;{\mu}g\;protein/ml$). Amino acid analysis showed major quantities of glutamic acid, leucine, lysine for 2'and aspartic acid, threonine for 4' respectively.

  • PDF