• Title/Summary/Keyword: 완전 무치악

Search Result 133, Processing Time 0.025 seconds

A Literature Review on Implant Assisted Removable Partial Denture (임플란트를 이용한 국소의치에 관한 문헌고찰)

  • Lee, Ji-Hye;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • The installation of an implant in the distal extension area to assist a partial dentrue (IARPD) was used carefully in clinical situations. The purpose of this review on the IARPD is describing the concept, clinical results and guidelines of IARPD. For the review, a literature search was performed using the PubMed. The data from the literature suggest that the placement of the implants could improve function and patient satisfaction. In addition, IARPD reduced the residual ridge resorption. Longer and wider implant should be placed. Less than $15^{\circ}$ angulation may be not harmful. To prevent the loosening of the abutment, modified abutment or resilient attachment should be used. However, the connection method between the clasp retention and IARPD should be considered for long time success. Moreover, longitudinal clinical studies are required for evaluation of IARPD.

Implant overdenture of mandible with severe unilateral atrophy: Report of two cases (심한 편측 하악 치조골 흡수를 보이는 환자에서의 임플란트 피개의치 수복 증례)

  • Kim, So-Yeun;Kwon, Eun-Young;Jung, Kyoung-Hwa;Jeon, Hye-Mi;Baek, Young-Jae;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.271-279
    • /
    • 2019
  • There are several unfavorable conditions regarding alveolar bone condition that may compromise the denture patient's satisfaction. Chewing efficiency may not be satisfactory when alveolar bone is deficient, and the denture stability could hardly be achieved when alveolar bone shape is irregular. Implant overdenture can be useful to provide satisfactory denture experience compared to conventional denture. The attachment for implant overdenture can be classified into bar attachment and solitary attachment. When the positions of the implants are in the mandibular anterior region, bar attachment may be favorable to obtain a rigid support of the entire denture. When implants are distributed both on anterior and posterior region, a solitary attachment could be considered for ease of removal and maintenance. This report presents implant overdenture cases with the patients that had unilateral mandibular alveolar bone atrophy conditions. Different abutments were chosen based on the individual patient's mandibular alveolar bone condition and the treatments were successful in terms of patient satisfaction.

Full mouth rehabilitation with implant-supported fixed prosthesis via dental CAD-CAM system (Dental CAD-CAM system을 통한 고정성 전악 임플란트 수복 증례)

  • Hong, Jeong-Min;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.97-106
    • /
    • 2021
  • Dental implants should be placed at ideal sites for implant-supported restorations. For a patient with insufficient residual ridge, mouth preparation including surgical intervention can be indicated to establish a soft and hard tissue environment favorable for a definitive prosthesis. Prosthodontic design based on computer-guided surgery and computer-aided design-computer-aided manufacturing (CAD-CAM) provides a visual blueprint allowing a clinician to assess the necessity of such a surgical intervention beforehand. In this case, a definitive restoration was planned and made via a CAD-CAM system according to the patient's oral status before treatment, simulated surgical interventions and serial provisional restorations. Based on the planning, a guided template was made and the implants were installed with bone augmentation using the template. Customized abutments, the first and the second provisional restorations were designed and fabricated by CAD-CAM. The definitive restorations were digitally made following the shape of the second provisional prostheses, which were confirmed in the patient's mouth. The patient was satisfied with the masticatory, phonetic and aesthetic functions of these definitive prostheses.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

'All-on-4' fixed implant supported prosthesis restoration using digital workflow: a case report (Digital workflow를 활용한 'All-on-4' 임플란트 지지 고정성 보철물 수복 증례)

  • Sungwoo Ju;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Kung-Rock Kwon;Hyeong-Seob Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.316-327
    • /
    • 2023
  • In the case of fully edentulous patients with severe alveolar bone resorption, the consideration of 'All-on-X' implant-supported fixed prosthesis after placing four or more implants in the anterior maxilla is possible. Recent advancements in digital dentistry have enabled systematic and predictable treatment in all phases, including diagnosis, surgery, and prosthesis fabrication. By incorporating digital dentistry techniques such as digital complete denture, implant surgical guides, facial scanning into the conventional restoration process, it is possible to reduce the complexity of the prosthesis fabrication and effectively achieve the transition from provisional prosthesis to definitive prosthesis in terms of both aesthetics and function.

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.

A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants (스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구)

  • Baik, Sang-Hyun;Jang, Ik-Tae;Kim, Sung-Kyun;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.157-168
    • /
    • 2008
  • Statement of problem: Over the past two decades, implant supported fixed prosthesis have been widely used. However, there are few studies conducted systematically and intensively on the splinting effect of implant systems in mandible. Purpose: The purpose of this study was to investigate the changes in stress distributions in the mandibular implants with splinting or non-splinting crowns by performing finite element analysis. Materials and methods: Cortical and cancellous bone were modeled as homogeneous, transversely isotropic, linearly elastic. Perfect bonding was assumed at all interfaces. Implant models were classified as follows. Group 1: $Br{{\aa}}nemark$ length 8.5mm 13mm splinting type Group 2: $Br{{\aa}}nemark$ length 8.5mm 13mm Non-splinting type Group 3: ITI length 8.5mm 13mm splinting type Group 4: ITI length 8.5mm 13mm Non-splinting type An load of 100N was applied vertically and horizontally. Stress levels were calculated using von Mises stresses values. Results: 1. The stress distribution and maximum von Mises stress of two-length implants (8.5mm, 13mm) was similar. 2. The stress of vertical load concentrated on mesial side of implant while the stress of horizontal load was distributed on both side of implant. 3. Stress of internal connection type was spreading through abutment screw but the stress of external connection type was concentrated on cortical bone level. 4. Degree of stress reduction was higher in the external connection type than in the internal connection type.

The effect of screw tightening techniques on the detorque value in internal connection implant superstructure (내부연결 임플란트 상부구조물에서 나사조임술식이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.243-250
    • /
    • 2010
  • Purpose: This study evaluated the effect of different screw tightening sequences and methods on detorque values in a well-fitting implant superstructure. Materials and methods: A fully edentulous mandibular master model and a metal framework directly connected to four parallel implants (Astra Tech) with a passive fit to each other were fabricated. Six stone casts were made with a splinted impression technique to represent a 'well-fitting' situation with the metal framework. Detorque values were measured twice after screw tightening using 20 Ncm. Detorque values and minimum detorque values for three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and for two tightening methods (two-step and one-step) were analyzed using multi-way analysis of variance and two-way analysis of variance, respectively, at a .05 level of significance. Results: The mean detorque values for screw tightening sequences ranged from 12.8 Ncm (2-4-3-1) to 13.1 Ncm (2-3-1-4), and for screw tightening methods were 13.1 Ncm (two-step) and 11.8 Ncm (one-step). The mean of mimimum detorque values for screw tightening sequences were 11.1 Ncm (1-2-3-4) and 11.2 Ncm (2-4-3-1 and 2-3-1-4), and for screw tightening methods were 11.2 Ncm (two-step) and 9.9 Ncm (one-step). No statistically significant differences among three screw tightening sequences were found for detorque values and for mimimum detorque values. But, statistically significant differences between two screw tightening methods were found for two values. Two-step screw tightening method showed higher detorque value (P = .0003) and higher minimum detorque value (P = .0035) than one-step method. Conclusion: Within the limitations of this study, the screw tightening sequence was not a critical factor for the detorque values in a well-fitting implant superstructure by the splinted impression technique. But, two-step screw tightening method showed greater detorque values than one-step method.