• Title/Summary/Keyword: 온실난방

Search Result 212, Processing Time 0.029 seconds

Inventory of Carbon Dioxide Emission in Carbon Cycle Community (The case study on Gyeongbuk Bonghwa-gun Chunyang-myeon Seobyeok-ri) (탄소순환마을의 이산화탄소배출량 조사연구 (경상북도 봉화군 춘양면 서벽리를 중심으로))

  • Kim, Hyo-Jin;Byun, Woo-Hyuk;Lim, Min-Woo;Park, Won-Kyoung;Kim, Min-Su
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.4
    • /
    • pp.597-602
    • /
    • 2010
  • The most basic matter to establish forest carbon circulation village is statistic on greenhouse gas emissions. But currently, although there is statistic on greenhouse gas emissions in the level of city or province, there is not statistic on greenhouse gas emission in village unit. According to the results, The model area is located in Seobyeok-ri, Chunyang-myeon, Bonghwa-gun, Gyeongsangbuk-do, the total $CO_2$emissions caused by energy used in the model area was $1,755tCO_2$. Heating accounts for 55% of total emissions followed by 23% for power and 22% for vehicles. The model area emitted $572tCO_2$ due to rice growing and livestock raising, accounting for approximately 24.5% of total $CO_2$ emissions. It is expected that a reduction of as much as $884tCO_2$ emissions will be made from the current $964tCO_2$ to a level of 1/12th that amount, or $80tCO_2$ by replacing heating energy currently used in the model area with wood bioenergy such as wood chips or pellets. In addition, carbon emission reduction is expected for both heating and power by replacing the power consumption in houses, buildings, and street lights with solar power.

Proper Installation Distance for Heating Effect of Nano-Carbon Fiber Infrared Heating Lamp for Stable Production of Watermelon Grafted Seedlings in Winter Season (동절기 수박 접목묘의 안정적 생산을 위한 나노탄소섬유적외선 램프의 난방효과에 대한 적정 설치간격)

  • Kim, Hye Min;Jeong, Hyeon Woo;Hwang, Hee Sung;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.8-13
    • /
    • 2022
  • This study was carried out to investigate the proper wattage and installation distance for the efficient use of nano-carbon fiber infrared heating lamp (NCFIHL), a heating device advantageous for heating energy saving, when the production of watermelon plug seedlings in the plug seedling nursery in winter season. Six small beds were divided into plastic film, and 700 W and 900 W nano-carbon fiber infrared heating lamps were installed at 100 cm above the bed. 1 lamp at central (control), 60 cm interval (2 lamps), and 40 cm interval (3 lamps) heating lamps were installed in each bed inside the greenhouse. All treatments, except the control, were set to keep the night air temperature at 20℃ after lighting the NCFIHL. The leaf temperature showed a tendency to increase fast as the install distance was narrow. The leaf length and leaf width tended to increase as the installation distance of the 700 W heating lamp was narrow. The compactness was high in 700 W heating lamp with 40 cm of installation distance. Therefore, in consideration of maintaining the set temperature at night, installing 700 W electric lamps at 40 cm was an efficient power and installation distance for watermelon grafted seedlings considering economic feasibility.

An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse (온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

A Study on the Night Thermal-storage Power Service : Sustainability and Energy Security (심야전력제도의 문제점과 개선 방향 : 경제성·환경성·형평성 및 에너지 안보)

  • Cho, Young-Tak;Kim, Chang-Seob
    • Environmental and Resource Economics Review
    • /
    • v.17 no.2
    • /
    • pp.419-455
    • /
    • 2008
  • This paper analyses the Night Thermal-storage Power Service(NTPS) from the perspective of sustainability. It investigates the economic, environmental and social aspects of NTPS, thereby reveals that NTPS triggers the inefficient use of fuel, the increase of carbon dioxide emission and the increase of cross subsidy between consumers. This paper also analyses NTPS from the perspective of energy security. It investigates how NTPS makes LNG demand volatile in winter, thus threatens our energy security. According to the analysis, NTPS directly violates two basic principles of national energy policy; Sustainability and Energy Security. To solve these problems, not only the harmonized adjustment of Heating Oil Tax and Electric Power Rates is needed to curb the rapier increase of NTPS, but also another separate policy is necessary for converting the electric heating system based on NTPS into the one based on Heating Oil.

  • PDF

Greenhouse Heating Characteristics of Heat Pump-Latent Heat Storage System (열펌프-잠열축열 시스템의 온실 난방 특성 연구)

  • 강연구;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.379-384
    • /
    • 2000
  • In order to use the natural thermal energy as much as possible for greenhouse heating, the air-air heat pump system involved PCM(phase change material) latent heat storage system was composed, and three types of greenhouse heating system(greenhouse system, greenhouse-PCM latent heat storage system, greenhouse-PCM latent heat storage-heat pump system) were recomposed from the greenhouse heating units to analyze the heating characteristics. The results could be concluded as follows; 1) In the greenhouse heated by the heat pump under the solar radiation of 406.39W/$m^2$, the maximum PCM temperature in the latent heat storage system was 24$^{\circ}C$ and the accumulated thermal energy stored in PCM mass of 816kg during the daytime was 100,320kJ. In the greenhouse without heat pump under the maximum solar radiation of 452.83W/$m^2$, the maximum PCM temperature in the latent heat storage system was 22$^{\circ}C$ and the accumulated thermal energy stored during the daytime was 52.250kJ. 2) In the greenhouse-PCM system without heat pump the heat stored in soil layers from the surface to 30cm of the soil depth was 450㎉/$m^2$. 3) In all of the greenhouse heating systems, the difference between the air temperature in greenhouse and the ambient temperature was about 20~23$^{\circ}C$ in the daytime. In the greenhouse without heat pump and PCM latent heat storage system the difference between the ambient temperature and the air temperature in the greenhouse was about 6~7$^{\circ}C$ in the nighttime, in the greenhouse with only PCM latent heat storage system the temperature difference about 7~13$^{\circ}C$ in the nighttime and in the greenhouse with the heat pump and PCM latent heat storage system about 9~14$^{\circ}C$ in the nighttime.

  • PDF

Design and Utilization of climagraph for Analysis of Regional Suitability of Greenhouse Cropping in Korea (국내 온실재배의 적지성 분석을 위한 Climagraph의 작성과 이용)

  • 이현우;이석건;이종원
    • Journal of Bio-Environment Control
    • /
    • v.9 no.2
    • /
    • pp.107-114
    • /
    • 2000
  • We constructed climagraphs for 16 regions of Korea by using the average monthly minimum air temperature, maximum air temperature and global radiation. We characterized the outside climate requirements corresponding to the climate requirements of crops in greenhouses. The climagraphs allow to decide the appropriate climate periods for greenhouse cultivation without heating and cooling equipment. These graphs may be used for analyzing climatic characteristic of a given area, selecting the suitable region and greenhouse and making a rational plan for greenhouse cropping in Korea. We found difficulty in deciding the beginning and end of greenhouse heating and cooling period due to insufficient references.

  • PDF

Environmental Prediction in Greenhouse According to Modified Greenhouse Structure and Heat Exchanger Location for Efficient Thermal Energy Management (효율적인 열에너지 관리를 위한 온실 형상 및 열 교환 장치 위치 개선에 따른 온실 내부 환경 예측)

  • Jeong, In Seon;Lee, Chung Geon;Cho, La Hoon;Park, Sun Yong;Kim, Seok Jun;Kim, Dae Hyun;Oh, Jae-Heun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.278-286
    • /
    • 2021
  • In this study, based on the Computational Fluid Dynamics (CFD) simulation model developed through previous study, inner environmenct of the modified glass greenhouse was predicted. Also, suggested the optimal shape of the greenhouse and location of the heat exchangers for heat energy management of the greenhouse using the developed model. For efficient heating energy management, the glass greenhouse was modified by changing the cross-section design and the location of the heat exchanger. The optimal cross-section design was selected based on the cross-section design standard of Republic of Korea's glass greenhouse, and the Fan Coil Unit(FCU) and the radiating pipe were re-positioned based on "Standard of greenhouse environment design" to enhance energy saving efficiency. The simulation analysis was performed to predict the inner temperature distribution and heat transfer with the modified greenhouse structure using the developed inner environment prediction model. As a result of simulation, the mean temperature and uniformity of the modified greenhouse were 0.65℃, 0.75%p higher than those of the control greenhouse, respectively. Also, the maximum deviation decreased by an average of 0.25℃. And the mean age of air was 18 sec. lower than that of the control greenhouse. It was confirmed that efficient heating energy management was possible in the modified greenhouse, when considered the temperature uniformity and the ventilation performance.

Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating (화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정)

  • Ryou, Young Sun;Kang, Youn Ku;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.372-378
    • /
    • 2012
  • This study was carried out in order to determine the optimum length of a roll type PE pipe heat exchanger employed in the water-to-water heat pump system using the waste heat of the heated effluent flowed out from thermal power generation plants as a heat source. And the heat pump system of 30 RT for an experimental test was designed and manufactured. And also PE pipes were employed to recover the waste heat from the heated effluent. The inside diameter of PE pipe heat exchanger was 20 mm, the thickness was 2 mm and the diameter of a roll was 1,000 mm. And from the results of this study, we found that the optimum length of PE pipe heat exchanger was 75 m per the heat pump capacity of 1.0 RT (3.51 kW) and then the heating COP of heat pump system was 3.8.

Effect of Heat Insulation by Plastic Curtain with Air Cell in Greenhouse (플라스틱 공기막 커튼을 활용한 온실의 보온력 향상)

  • Kim, Hak-Ju;Lee, Si-Young;Yeom, Sung-Hyun;Nam, Yooun-Il;Jeon, Hee;Yoon, Nam-Kyu
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.203-206
    • /
    • 2003
  • 우리나라 시설원예 면적은 '95년 43,093ha에서 '01년 말 현재 52,125ha로 연평균 3.2%의 증가율을 보인 반면 난방면적은 연평균 10.8%씩 증가하여 12,710ha로 전체 시설재배 면적의 24.4%를 차지하고 있다. 또한 난방연료의 95% 이상이 경유이며, 최근 국제정세 불안 등으로 유가가 급등하여 시설재배농가의 연료비 부담은 더욱 가중되고 있다. (중략)

  • PDF

Studies on light environment in water curtain house (수막(Water curtain)하우스의 광환경에 관한 연구)

  • Cho, Il-Hwan;Woo, Young-Hoi;Lee, Sung-Je;Jeon, Hee;Kim, Hyun-Hwan;Lee, Si-Young;Lee, Jung-Taek;Kim, Bok-Young
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1993.10a
    • /
    • pp.7-8
    • /
    • 1993
  • 1970년대의 오일쇼크는 시설재배 경영자로 하여금 성에너지를 효율적으로 이용케하는 연구에 박차를 가했다. 따라서 1970년대 후반에 남부지방에서는 지하수열을 이용하는 방법으로서 소위 Water curtain의 방법을 이용한 시설의 난방 방법이 넓게 확산되어갔다. Water curtain의 난방 방법은 통상 15$^{\circ}C$ 전후 수원의 지하수를 이용해 curtain 위에 살수함으로써 동기에 1$0^{\circ}C$ 정도의 온실의 유지가 가능하여 비교적 저염성 채소(토마토, 딸기 등)의 재배에 이용되고 있다. (중략)

  • PDF