• Title/Summary/Keyword: 오차원

Search Result 1,395, Processing Time 0.03 seconds

The Relationship between Financial Constraints and Investment Activities : Evidenced from Korean Logistics Firms (우리나라 물류기업의 재무제약 수준과 투자활동과의 관련성에 관한 연구)

  • Lee, Sung-Yhun
    • Journal of Korea Port Economic Association
    • /
    • v.40 no.2
    • /
    • pp.65-78
    • /
    • 2024
  • This study investigates the correlation between financial constraints and investment activities in Korean logistics firms. A sample of 340 companies engaged in the transportation sector, as per the 2021 KSIC, was selected for analysis. Financial data obtained from the DART were used to compile a panel dataset spanning from 1996 to 2021, totaling 6,155 observations. The research model was validated, and tests for heteroscedasticity and autocorrelation in the error terms were conducted considering the panel data structure. The relationship between investment activities in the previous period and current investment activities was analyzed using panel Generalized Method of Moments(GMM). The validation results of the research indicate that Korean logistics firms tend to increase investment activities as their level of financial constraints improves. Specifically, a positive relationship between the level of financial constraints and investment activities was consistently observed across all models. These findings suggest that investment decision-making varies based on the financial constraints faced by companies, aligning with previous research indicating that investment activities of constrained firms are subdued. Moreover, while the results from the model examining whether investment activities in the previous period affect current investment activities indicated an influence of investment activities from the previous period on current investment activities, the investment activities from two periods ago did not show a significant relationship with current investment activities. Among the control variables, firm size and cash flow variables exhibited positive relationships, while debt size and asset diversification variables showed negative relationships. Thus, larger firm size and smoother cash flows were associated with more proactive investment activities, while high debt levels and extensive asset diversification appeared to constrain investment activities in logistics companies. These results interpret that under financial constraints, internal funding sources such as cash flows exhibit positive relationships, whereas external capital sources such as debt demonstrate negative relationships, consistent with empirical findings from previous research.

A Study of Organic Matter Fraction Method of the Wastewater by using Respirometry and Measurements of VFAs on the Filtered Wastewater and the Non-Filtered Wastewater (여과한 하수와 하수원액의 VFAs 측정과 미생물 호흡률 측정법을 이용한 하수의 유기물 분액 방법에 관한 연구)

  • Kang, Seong-wook;Cho, Wook-sang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.58-72
    • /
    • 2009
  • In this study, the organic matter and biomass was characterized by using respirometry based on ASM No.2d (Activated Sludge Model No.2d). The activated sludge models are based on the ASM No.2d model, published by the IAWQ(International Association on Water Quality) task group on mathematical modeling for design and operation of biological wastewater treatment processes. For this study, OUR(Oxygen Uptake Rate) measurements were made on filtered as well as non-filtered wastewater. Also, GC-FID and LC analysis were applied for the estimation of VFAs(Volatile Fatty Acids) COD(S_A) in slowly bio-degradable soluble substrates of the ASM No.2d. Therefore, this study was intended to clearly identify slowly bio-degradable dissolved materials(S_S) and particulate materials(X_I). In addition, a method capable of determining the accurate time to measure non-biodegradable COD(S_I), by the change of transition graphs in the process of measuring microbial OUR, was presented in this study. Influent fractionation is a critical step in the model calibrations. From the results of respirometry on filtered wastewater, the fraction of fermentable and readily biodegradable organic matter(S_F), fermentation products(S_A), inert soluble matter(S_I), slowly biodegradable matter(X_S) and inert particular matter(X_I) was 33.2%, 14.1%, 6.9%, 34.7%, 5.8%, respectively. The active heterotrophic biomass fraction(X_H) was about 5.3%.

Model Evaluation for Predicting the Full Bloom Date of Apples Based on Air Temperature Variations in South Korea's Major Production Regions (기온 변화에 따른 우리나라 사과 주산지 만개일 예측을 위한 모델 평가)

  • Jae Hoon Jeong;Jeom Hwa Han;Jung Gun Cho;Dong Yong Lee;Seul Ki Lee;Si Hyeong Jang;Suhyun Ryu
    • Journal of Bio-Environment Control
    • /
    • v.32 no.4
    • /
    • pp.501-512
    • /
    • 2023
  • This study aimed to assess and determine the optimal model for predicting the full bloom date of 'Fuji' apples across South Korea. We evaluated the performance of four distinct models: the Development Rate Model (DVR)1, DVR2, the Chill Days (CD) model, and a sequentially integrated approach that combined the Dynamic model (DM) and the Growing Degree Hours (GDH) model. The full bloom dates and air temperatures were collected over a three-year period from six orchards located in the major apple production regions of South Korea: Pocheon, Hwaseong, Geochang, Cheongsong, Gunwi, and Chungju. Among these models, the one that combined DM for calculating chilling accumulation and the GDH model for estimating heat accumulation in sequence demonstrated the most accurate predictive performance, in contrast to the CD model that exhibited the lowest predictive precision. Furthermore, the DVR1 model exhibited an underestimation error at orchard located in Hwaseong. It projected a faster progression of the full bloom dates than the actual observations. This area is characterized by minimal diurnal temperature ranges, where the daily minimum temperature is high and the daily maximum temperature is relatively low. Therefore, to achieve a comprehensive prediction of the blooming date of 'Fuji' apples across South Korea, it is recommended to integrate a DM model for calculating the necessary chilling accumulation to break dormancy with a GDH model for estimating the requisite heat accumulation for flowering after dormancy release. This results in a combined DM+GDH model recognized as the most effective approach. However, further data collection and evaluation from different regions are needed to further refine its accuracy and applicability.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse (강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.78-85
    • /
    • 2019
  • This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.