• Title/Summary/Keyword: 오차비율

Search Result 485, Processing Time 0.025 seconds

Location Error Reduction method using Iterative Calculation in UWB system (Iterative Calculation을 이용한 UWB 위치측정에서의 오차감소 기법)

  • Jang, Sung-Jeen;Hwang, Jae-Ho;Choi, Nack-Hyun;Kim, Jae-Moung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.12
    • /
    • pp.105-113
    • /
    • 2008
  • In Ubiquitous Society, accurate Location Calculation of user's device is required to achieve the need of users. As the location calculation is processed by ranging between transceivers, if some obstacles exist between transceivers, NLoS(Non-line-of-Sight) components of received signal increase along with the reduction of LoS(Line-of-Sight) components. Therefore the location calculation error will increase due to the NLoS effect. The conventional location calculation algorithm has the original ranging error because there is no transformation of ranging information which degrades the ranging accuracy. The Iterative Calculation method which minimizes the location calculation error relys on accurately identifying NLoS or LoS condition of the tested channel. We employ Kurtosis, Mean Excess Delay and RMS Delay spread of the received signal to identify whether the tested channel is LoS or NLoS firstly. Thereafter, to minimize location calculation error, the proposed Iterative Calculation method iteratively select random range and finds the averaged target location which has high probability. The simulation results confirm the enhancement of the proposed method.

Robust tracking control for uncertain linear systems using linear matrix inequlities (선형행렬 부등식을 이용한 불확실한 선형시스템에 대한 강인 추적제어기)

  • Lee, Jae-Won;Kwon, Wook-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.3
    • /
    • pp.289-294
    • /
    • 1998
  • 본 논문에서는 상태행렬과 입력행렬에 시변 불확실성이 있는 선형시스템에 대한 강인 추적 제어기를 제안한다. 본 논문에서 대상으로 하는 불확실성은 block-diagonally structured uncertainty와 norm bounded uncertainty인데 모두 정합 조건을 만족시킬 필요는 없다. 폐루프 시스템이 불확실성하에서 안정할 수 있는 조건을 제시하고 이 조건이 선형행렬 부등식으로 나타낼 수 있음을 보인다. 추적 오차를 줄이고 오차 감소 비율을 증가시킬 수 있는 최적화 방법도 제아한다. 또한 불확실성의 크기가 0으로 줄어들면 추적 오차도 0으로 줄어듬을 보인다.

  • PDF

Potential Errors in Committed Effective Dose Due to the Assumption of a Single Intake Path in Interpretation of Bioassay Results (바이오어세이 결과 해석에서 단일 섭취경로 가정에 따르는 예탁유효선량의 잠재오차)

  • Lee, Jong-Il;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.135-140
    • /
    • 2006
  • Intakes of radionuclides through both inhalation and ingestion pathways may occur particularly in an incident involving unsealed radionuclides. If one assume only one intake path in this case, which is usual in routine monitoring, a significant error in the evaluated committed effective dose($E_{50}$) may result. In order to demonstrate the potential errors, variations of the resulting committed effective doses were analyzed for different fractions of the inhaled activities to the total intake of $^{241}Am$. Simulated bioassav measurements for the lungs, urine and feces were generated based on the biokinetic model and data of the radionuclide, 5 ${\mu}m$ AMAD and absorption type M for inhalation, for various inhalation fractions. The potential errors in $E_{50}$ due to the assumption of one intake path were in the range from -100% to as large as +34,000% when the bioassays were made 3 days after the intakes. Larger errors are expected when only the feces assay is applied while inhalation intake exists. A strategy which employs two types of bioassay was proposed to reduce the error caused by a misjudgement of the intake path.

Development of Performance Evaluation Formula for Deep Learning Image Analysis System (딥러닝 영상분석 시스템의 성능평가 산정식 개발)

  • Hyun Ho Son;Yun Sang Kim;Choul Ki Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.4
    • /
    • pp.78-96
    • /
    • 2023
  • Urban traffic information is collected by various systems such as VDS, DSRC, and radar. Recently, with the development of deep learning technology, smart intersection systems are expanding, are more widely distributed, and it is possible to collect a variety of information such as traffic volume, and vehicle type and speed. However, as a result of reviewing related literature, the performance evaluation criteria so far are rbs-based evaluation systems that do not consider the deep learning area, and only consider the percent error of 'reference value-measured value'. Therefore, a new performance evaluation method is needed. Therefore, in this study, individual error, interval error, and overall error are calculated by using a formula that considers deep learning performance indicators such as precision and recall based on data ratio and weight. As a result, error rates for measurement value 1 were 3.99 and 3.54, and rates for measurement value 2 were 5.34 and 5.07.

A Study on the Performance Improvement of OFDM System (OFDM 시스템의 성능 개선에 관한 연구)

  • 문경섭
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.485-488
    • /
    • 2004
  • 본 논문에서는 OFDM(Orthogonal Frequency Division Multiplexing :직교 주파수 분할 다중화) 전송방식을 사용한 시스템에서 주파수 옵셋으로 인한 동기 오차의 발생이 수신시스템에 미치는 영향을 분석하고 성능 개선기법으로 BCH부호기법을 적용하여 수신성능의 개선정도를 분석하였다. 결과에 의하면, BCH부호기법을 사용함으로써 T$_{s}$ f=0.02일 때 약 2dB의 BER 개선을 보였고, $\alpha$의 영향을 적게 받음을 알 수 있었고, T$_{s}$ f=0.05일 경우는 가드 인터벌 비율$\alpha$가 증가함에 따라 5dB이상의 BER 개선을 보이나 $\alpha$가 0.25이상에서는 여전히 요구되는 기준 BER를 만족하지 못함을 알 수 있었다. 또한, 낮은 수신전력(10dB)에서는 가드인터벌 비율의 변화보다는 주파수 옵셋량이 시스템 성능에 영향을 미침을 알 수 있고, 높은 수신전력에서는 (20dB) 주파수 옵셋량에 대해서는 강인한 성능을 보이지만 가드 인터벌 비율의 증가에 따라 BER 특성이 열화되는 것을 알 수 있었다.

  • PDF

Some Statistical Issues to Compare the Two Proportions in a Sample Survey (동일조사에서 비율비교와 관련된 두 가지 흔한 오류)

  • 김현철
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.1
    • /
    • pp.169-179
    • /
    • 2003
  • We suggest two types of misuses to analyze the same survey data. One is related with the fact that people nay use the wrong bounds of error when they compare two proportions. And the other is related with that some non-statisticians are apt to use wrong methods when there is a neutral answer in a question. We suggest these methods and compare them with the statistically good method. It will be a good results in educational purpose.

Performance Improvement of Coded OFDM Systems Considering frequency Offset (주파수 옵셋을 고려한 부호화 OFDM 시스템의 성능 개선)

  • 강희조
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.482-485
    • /
    • 2004
  • 본 논문에서는 OFDM(Orthogonal Frequency Division Multiplexing) 전송방식과 DQPSK변조방식을 제안하고, 반송파에서 주파수 옵셋으로 인한 동기 오차의 발생이 수신시스템에 미치는 영향을 분석하고 성능 개선기법으로 부호기법을 적용하여 수신 성능의 개선정도를 분석하였다. 결과에 의하면, 부호기법을 사용함으로써 T$_{s}$ $\Delta$f=0.02일 때 약 2㏈의 BER 개선을 보였고, $\alpha$의 영향을 적게 받음을 알 수 있었고, T$_{s}$ $\Delta$f=0.05일 경우는 보호대역 비율$\alpha$가 증가함에 파라 5㏈이상의 BER 개선을 보이나 $\alpha$가 0.25이상에서는 여전히 요구되는 기준 BER를 만족하지 못함을 알 수 있었다. 또한, 낮은 수신전력(10 ㏈)에서는 보호대역 비율의 변화보다는 주파수 옵셋량이 시스템 성능에 영향을 미침을 알 수 있고, 높은 수신전력에서는(20 ㏈) 주파수 옵셋량에 대해서는 강인한 성능을 보이지만 보호대역 비율의 증가에 따라 BER 특성이 열화 되는 것을 알 수 있었다.

  • PDF

Dosimetric Verification of Dynamic Conformal Arc Radiotherapy (입체조형 동적회전조사 방사선치료의 선량 검증)

  • Kim Tae Hyun;Shin Dong Ho;Lee Doo Hyun;Park Sung Yong;Yun Myung Guen;Shin Kyung Hwan;Py Hong Ryull;Kim Joo-Young;Kim Dae Yong;Cho Kwan Ho;Yang Dae-Sik;Kim Chul-Yong
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.166-175
    • /
    • 2005
  • The purpose of this study is to develop the optimization method for adjusting the film isocenter shift and to suggest the quantitative acceptable criteria for film dosimetry after optimization In the dynamic conformal arc radiation therapy (DCAR). The DCAR planning was peformed In 7 patients with brain metastasis. Both absolute dosimetry with ion chamber and relative film dosimetry were peformed throughout the DCAR using BrainLab's micro-multileaf collimator. An optimization method for obtaining the global minimum was used to adjust for the error in the film isocenter shift, which is the largest pan of systemic errors. The mean of point dose difference between measured value using ion chamber and calculated value acquired from planning system was $0.51{\pm}0.43\%$ and maximum was $1.14\%$ with absolute dosimetry These results were within the AAPM criteria of below $5\%$. The translation values of film isocenter shift with optimization were within ${\pm}$1 mm in all patients. The mean of average dose difference before and after optimization was $1.70{\pm}0.35\%$ and $1.34{\pm}0.20\%$, respectively, and the mean ratios over $5\%$ dose difference was $4.54{\pm}3.94\%$ and $0.11{\pm}0.12\%$, respectively. After optimization, the dose differences decreased dramatically and a ratio over $5\%$ dose difference and average dose difference was less than $2\%$. This optimization method is effective in adjusting the error of the film isocenter shift, which Is the largest part of systemic errors, and the results of this research suggested the quantitative acceptable criteria could be accurate and useful in clinical application of dosimetric verification using film dosimetry as follows; film isocenter shift with optimization should be within ${\pm}$1 mm, and a ratio over $5\%$ dose difference and average dose difference were less than $2\%$.

  • PDF

Estimation of Volume-Area-Depth Relationship for Shallow Wetland (습지의 체적-면적-깊이에 대한 관계식 추정)

  • Kim, Jun-Gwon;Kim, Hyeong-Su;Jeong, Sang-Man
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.231-240
    • /
    • 2002
  • The wetland has very important functions in hydrologic and ecological aspects and the research of wetland functions requires the basic hydrological properties such as water quantity. However, we do not have a research work on the hydrological properties for a wetland study in Korea. Therefore, this study is to estimate the relations between the volume(V), the area(A), and the depth(h) of water in the wetland which might be the basis for the wetland research in Korea. To estimate the relations, we derive the basic equations, obtain the surveyed data and do modelling, and estimate the relations of A-h and V-h using the Surfer program. The estimated and observed volumes for 5-wetland are compared and the errors are in the range of 2 % to 11 % for 4-wetland and 34 % for the rest. The wetlands in small errors showed the similar ones with the profile of the wetted perimeter which is assumed for the derivation of the equation but the wetland of large error has much different profile with the assumed one. We re-estimate the volumes for 3-wetland(W3, W4, W5) which showed the large errors due to the bended profiles of the wetland slopes. say, after the slopes was divided into two parts of upper and lower ones, the volumes were estimated. From our re-estimation, we obtained very good results ranged from 1 % to 8 % in their errors. We conjecture that the procedure suggested in this study might be useful as a reference for the future research on the relations of V-A-h in Korea.

Characteristics of Speckle Errors of SeaWiFS Chlorophyll-$\alpha$ in the East Sea (동해 SeaWiFS 클로로필-$\alpha$ 농도의 스펙클 오차 특성)

  • Chae, Hwa-Jeong;Park, Kyung-Ae
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.337-343
    • /
    • 2009
  • 1997년 9월부터 2007년 12월까지 인공위성 해색센서 SeaWiFS의 클로로필-$\alpha$ 농도가 가지는 오차 특성을 분석하고 그 원인을 조사하였다. 동해의 클로로필-$\alpha$ 월별 분포에는 비정상적으로 높은 농도값이 스펙클(speckle) 형태로 출현하였다. 스펙클들은 시공간적으로 연계성이 없이 산발적으로 분포하였으며 주변 평균에 대해 $10mg/m^3$ 이상의 편차를 보였다. 스펙클들은 주로 겨울철에 나타났으며 구름 분포와 관련이 있었다. 10년간 월별 운량 분석 결과 겨울철 운량은 다른 계절과 달리 남동해상에 집중적으로 분포하였으며, 운량이 클수록 스펙클의 농도가 크게 나타나는 통계적 특성을 보였다. 특히 스펙클이 나타나는 화소의 각 밴드별 정규화된 수출광량을 분석해 본 결과 짧은 파장 영역(443, 490, 510 nm)은 전체적으로 수출광량이 낮게 나타난 반면 550 nm 밴드는 정상 화소와 유사한 분포를 보였다. 짧은 파장 영역의 낮은 수출광량은 555 nm 밴드에 대한 비율로 구해지는 클로로필-$\alpha$ 농도값을 비정상적으로 증폭시켰으며 SeaWiFS 자료에 스펙클을 유발하였다. 본 연구는 동해의 SeaWiFS 클로로필-$\alpha$ 농도자료가 지니는 스펙클 오차에 대한 문제점을 제기하고 오차 특성 분석을 통해 좀 더 신뢰도 있는 자료를 해양 응용 연구에 사용해야 함을 제시한다.

  • PDF