• 제목/요약/키워드: 오차교정

Search Result 292, Processing Time 0.029 seconds

Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera (저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정)

  • Kim, Seo Woo;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.2
    • /
    • pp.99-109
    • /
    • 2018
  • The precision of the vibration-sensors, contact or non-contact types, is usually satisfactory for the practical measurement applications, but a sensor is confined to the measurement of a point or a direction. Although the precision and frequency span of the low-cost camera are inferior to these sensors, it has the merits in the cost and in the capability of simultaneous measurement of a large vibrating area. Furthermore, a camera can measure multi-degrees-of-freedom of a vibrating object simultaneously. In this study, the calibration method and the dynamic characteristics of the low-cost machine vision camera as a sensor are studied with a demonstrating example of the two-dimensional vibration of a cantilever beam. The planar image of the camera shot reveals two rectilinear and one rotational motion. The rectilinear vibration motion of a single point is first measured using a camera and the camera is experimentally calibrated by calculating error referencing the LDV (Laser Doppler Vibrometer) measurement. Then, by measuring the motion of multiple points at once, the rotational vibration motion and the whole vibration motion of the cantilever beam are measured. The whole vibration motion of the cantilever beam is analyzed both in time and frequency domain.

Analysis of Shipping Markets Using VAR and VECM Models (VAR과 VECM 모형을 이용한 해운시장 분석)

  • Byoung-Wook Ko
    • Korea Trade Review
    • /
    • v.48 no.3
    • /
    • pp.69-88
    • /
    • 2023
  • This study analyzes the dynamic characteristics of cargo volume (demand), ship fleet (supply), and freight rate (price) of container, dry bulk, and tanker shipping markets by using the VAR and VECM models. This analysis is expected to enhance the statistical understanding of market dynamics, which is perceived by the actual experiences of market participants. The common statistical patterns, which are all shown in the three shipping markets, are as follows: 1) The Granger-causality test reveals that the past increase of fleet variable induces the present decrease of freight rate variable. 2) The impulse-response analysis shows that cargo shock increases the freight rate but fleet shock decreases the freight rate. 3) Among the three cargo, fleet, and freight rate shocks, the freight rate shock is overwhelmingly largest. 4) The comparison of adjR2 reveals that the fleet variable is most explained by the endogenous variables, i.e., cargo, fleet, and freight rate in each of shipping markets. 5) The estimation of co-integrating vectors shows that the increase of cargo increases the freight rate but the increase of fleet decreases the freight rate. 6) The estimation of adjustment speed demonstrates that the past-period positive deviation from the long-run equilibrium freight rate induces the decrease of present freight rate.

Inverse Estimation of Viscoplastic Properties of Solder Alloy Using Moir$\acute{e}$ Interferometry and Computer Model Calibration (모아레 간섭계와 모델교정법을 이용한 솔더 합금의 점소성 물성치 역추정)

  • Gang, Jin-Hyuk;Lee, Bong-Hee;Joo, Jin-Won;Choi, Joo-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.97-106
    • /
    • 2011
  • In this study, viscoplastic material properties of solder alloy which is used in the electronics packages are inversely estimated. A specimen is fabricated to this end, and an experiment is conducted to examine deformation by Moir$\acute{e}$ interferometry. As a result of the experiment, bending displacement of the specimen and shear strain of the solder are obtained. A viscoplastic finite element analysis procedure is established, and the material parameters are determined to match closely with the experiments. The uncertainties which include inherent experimental error and insufficient data of experiments are addressed by using the method of computer model calibration. As a result, material parameters are identified in the form of confidence interval, and the displacements and strains using these parameters are predicted in the form the prediction interval.

Implementation on the Portable Blood Gas Analyzer and Performance Estimation (휴대형 혈액가스분석 시스템의 구현 및 성능평가)

  • Jeong, Do-Un;Jeon, Gye-Rok;Bae, Jin-Woo;Kim, Gil-Jung;Sim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • In this study, we implemented the measurement of pH, $pO_2$, $pCO_2$ of the arterial blood on a portable blood gas analysis system. This system is consist of two parts of hardware and software. The hardware part is divided into a fluidic mechanism and an electronic circuit unit. The system program is composed of operating, washing, correcting, and measuring routines. Both of 1-point and 2-point calibration schemes were used to enhance the accuracy of the measurement. In order to evaluate the performance of the developed system, we measured and performed statistical analysis on the characteristics of the sensing electrode response. As a result, coefficient variation was within 1.12, and maximum error was within 1.298%. We confirmed development possibility of portable blood gas analyzer.

Comparison of computer-based treatment prediction with true results in bimaxillary protrusion cases (치조성 양악 전돌 환자에서 컴퓨터를 이용한 치료 결과 예측의 정확성)

  • Lee, Rhi-na;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.155-163
    • /
    • 2002
  • This study was performed to assess the accuracy of computer-based treatment prediction for soft tissue profile using Quick Ceph Image $Pro^{TM}\;&\;Quick\;Ceph\;2000^{TM}$ in bimaxillary protrusion cases. The Ore- and post-treatment lateral cephalograms of 21 female adults treated by low first premolar extraction were imaged and 9 landmarks and 27 specific soft tissue mesurements were digitized for comparing actual treatment results with computer simulations. The results of this study showed that Quick Ceph Image $Pro^{TM}\;&\;Quick\;Ceph\;2000^{TM}$ tends to overestimeate horizontal changes and underestimate vertical changes. In the computer simulation, upper lip showed rolling tendency. The upper lip measurements were disposed to be regular direction hut lower lip measurements were varied case by case even if it was statistically insignificant.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

Mixed dentition analysis using a multivariate approach (다변량 기법을 이용한 혼합치열기 분석법)

  • Seo, Seung-Hyun;An, Hong-Seok;Lee, Shin-Jae;Lim, Won Hee;Kim, Bong-Rae
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.112-119
    • /
    • 2009
  • Objective: To develop a mixed dentition analysis method in consideration of the normal variation of tooth sizes. Methods: According to the tooth-size of the maxillary central incisor, maxillary 1st molar, mandibular central incisor, mandibular lateral incisor, and mandibular 1st molar, 307 normal occlusion subjects were clustered into the smaller and larger tooth-size groups. Multiple regression analyses were then performed to predict the sizes of the canine and premolars for the 2 groups and both genders separately. For a cross validation dataset, 504 malocclusion patients were assigned into the 2 groups. Then multiple regression equations were applied. Results: Our results show that the maximum errors of the predicted space for the canine, 1st and 2nd premolars were 0.71 and 0.82 mm residual standard deviation for the normal occlusion and malocclusion groups, respectively. For malocclusion patients, the prediction errors did not imply a statistically significant difference depending on the types of malocclusion nor the types of tooth-size groups. The frequency of prediction error more than 1 mm and 2 mm were 17.3% and 1.8%, respectively. The overall prediction accuracy was dramatically improved in this study compared to that of previous studies. Conclusions: The computer aided calculation method used in this study appeared to be more efficient.

A STUDY ON ACCURACY OF MAXILLARY REPOSITIONING BY EXTERNAL MEASURING TECHIQUE (외부계측법에 의한 상악골 이동의 위치적 정확도에 대한 평가 연구)

  • Park, Hyung-Sik;Cha, In-Ho;Park, Hyung-Rae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.44-52
    • /
    • 1991
  • Internal measurement technique has been commonly and classically used to guide down-fractured maxilla by Le Fort I osteotomy into its new position during intraoperative procedure for correlating preoperative model works with surgery. However, It has been challenged now by several authors due to some problems as its inaccuracy in three-dimensional changes at surgery, difficulty to measure during surgery and impossibility of rechecking at the end of surgery etc. The purpose of this study was to evaluate the accuracy of maxillary movement by external measuring technique and to determine its accuracy between the prediction tracing and a new maxillary position. The results indicate that the external measuring technique was predictable in the vertical, horizontal and transverse change of the maxilla as its prediction, however, it has a tendency to shift the maxilla more anterior and inferior in overall direction than prediction. Post-operative canting difference were mimic, however Ehange of the maxillary dental midline was large and had a right-shifting tendency.1 The precise methods to keep maxillary dental midline as same as prediction and the avoidance of uneven force applied to the mandible for autorotation should be necessary during surgery in use of external measurement technique.

  • PDF

Digital imaging of film-based cephalograms using a digital camera (디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환)

  • Wang, Sung-Jin;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.448-457
    • /
    • 2004
  • As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).

Biaxial Accelerometer-based Magnetic Compass Module Calibration and Analysis of Azimuth Computational Errors Caused by Accelerometer Errors (2 축 가속도계 기반 지자기 센서 모듈의 교정 및 가속도계 오차에 의한 방위각 계산 오차 분석)

  • Cho, Seong Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • A magnetic compass module must be calibrated accurately before use. Moreover, the calibration process must be performed taking into account any magnetic dip if the magnetic compass module has tilt angles. For this, a calibration method for a magnetic compass module is explained. Tilt error of the magnetic compass module is compensated using a biaxial accelerometer generally. The accelerometer error causes a tilt angle calculation error that gives rise to an azimuth calculation error. For error property analysis, error equations are derived and simulations are performed. In the simulation results, the accuracy of derived error equations is verified. If a biaxial magnetic compass module is used instead of a triaxial one, the magnetic dip and z-axis magnetic compass data must be estimated for tilt compensation. Lastly, estimation equations for the magnetic dip and z-axis magnetic compass data are derived, and the performance of the equations is verified based on a simulation.