• Title/Summary/Keyword: 오존 농도

Search Result 682, Processing Time 0.024 seconds

Influence of Ozonated Water and Washing Method Using Ozonated Water for Controlling Food-borne Disease Bacteria (오존수와 오존수를 이용한 세척방법이 식중독 세균 제어에 미치는 영향)

  • Park, Jeongmi;Shin, Han-Seung
    • Food Engineering Progress
    • /
    • v.14 no.4
    • /
    • pp.316-321
    • /
    • 2010
  • The efficacy of the ozonated water (0.1, 0.2, 0.4, 0.6, and 1.0 ppm) in reducing the risk of food-borne disease was investigated in this study. After inoculation of Listeria monocytogenes (ATCC 19112), Salmonella enterica subsp. enterica biovar Typhimurium (ATCC 12598), Escherichia coli O157:H7 (ATCC 43890) to lettuce, spinach, and beef, inhibition effect with different washing concentrations, time, and methods with ozonated and tap water were evaluated. As a result, there were 2.16 to 3.85 log CFU/mL reduction in different foods and 7 log CFU/mL reduction on cutting boards after watering with ozonated water. Higher than 0.2 ppm of ozonated water treatment reduced the growth of food-borne disease bacteria with increasing washing time and ozone concentration. These results suggested that the ozonated water treatment effectively improved the microbiological quality and food safety.

Vertical Ozone Distribution over Seoul: Ozonesonde Measurements During June 6~9, 2003 (서울지역 연직 오존 분포: 2003년 6월 6~9일 오존존데 관측)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Song, Sang-Keun;Lim, Yun-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.196-205
    • /
    • 2008
  • Variability in vertical ozone and meteorological profiles was measured by 2Z electrochemical concentration cells (ECC) ozonesonde at Bangyi in Seoul ($37.52^{\circ}N$, $127.13^{\circ}E$) during June $6{\sim}9$, 2003 in odor to identify the vertical distribution of ozone and its relationship with the lower-atmospheric structure resulted in the high ozone concentrations near the surface. The eight profiles obtained in the early morning and the late afternoon during the study period clearly showed that the substantial change of ozone concentrations in lower atmosphere(${\sim}5\;km$), indicating that it is tightly coupled to the variation of the planetary boundary layer (PBL) structure as well as the background synoptic flow. All profiles observed early in the morning showed very low ozone concentrations near the surface with strong vertical gradients in the nocturnal stable boundary layer due to the photochemical ozone loss caused by surface NO titration under very weak vertical mixing. On the other hand, relatively uniform ozone profiles in the developed mixing layer and the ozone peaks in the upper PBL, were observed in the late afternoon. It was noted that a significant increase in ozone concentrations in the lower atmosphere occurred with the corresponding decrease of the mixing height in the late afternoon on June 8. Ozone in upper layer did not vertically vary much compared to that in PBL but changed significantly on June 6 that was closely associated with the variation of synoptic flows. Interestingly, heavily polluted ozone layers aloft (a maximum value of 115 ppb around 2 km) were formed early in the morning on 6 through 7 June under dominant westerly synoptic flows. This indicates the effects of the transport of pollutants on regional scale and consequently can give a rise to increase the surface ozone concentration by downward mixing processes enhanced in the afternoon.

Effect of Ozone and UV Treatment of Groundwater on the Quality of Wine (지하수의 오존과 UV처리가 탁주의 품질특성에 미치는 영향)

  • Park, Young-Gyu;Kim, Hee-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.255-261
    • /
    • 2004
  • Experiments using ozone are presented for the water purification and wine quality improvement. Advanced oxidation process results reveal water treatment by both ozone and UV radiation increases quality of the takju prepared using a Korean conventional nuruk than with ozone-treatment or convectional method only. Water quality was enhanced by ozone treatment, resulting in 85% reduction of hardness, and 30% increase in total glucose produced due to increased conductivity and biodegradability of water. Although initially decreased slightly due to oxidation of takju, higher than expected ethanol production was observed, with ozone plus UV treatment resulting in 20% higher production compared with other methods.

Effectiveness of Uniconazole(XE-1019) Treatment in Reducing Ozone Injury to Tomato Plant (Uniconazole(XE-1019) 처리가 토마토의 오존피해경감에 미치는 효과)

  • Won, Dong-Chan;Ku, Ja-Hyeong;KIm, Tae-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.1
    • /
    • pp.41-49
    • /
    • 1992
  • To determine the efficacy of uniconzaole[(E)-1-(4-chlorophenyl)-4,4-dimethy 2-(1,2,4-triazol-1-yl)-1-penten-3-ol)](XE-1019) as a phytoprotectant against $O_3$ injury in tomato plants(Lycopersicon esculentum Mill. 'Pink Glory'), plants were given a 50ml soil drench of uniconazole solution at concentrations of 0.001, 0,01, 0.1 and 0.2mg/pot thirteen days prior to $O_3$ fumigation. All four uniconazole concentrations were effective in providing protection against $O_3$ exposure(16h at 0.3 ppm). Uniconazole treatment above 0.001 mg/pot significantly reduced stem elongation, leaf enlargement, leaf area and fresh weight of plant, whereas increased chlorophyll concentration. Transpiration rate on a whole plant basis was reduced by uniconazole treatment and $O_3$ exposure. Uniconazole reduced ethylene production induced by $O_3$ injury but had little or no effect on defoliation of cotyledons and leaf epinasty. Activities of peroxidase (POD) and superoxide dismutase(SOD) were slightly increased by application of uniconazole. With increasing exposure time, $O_3$ increased POD activity but decreased SOD activity. The phytoprotective effects of uniconazole were diminished by applying gibberellin at $10{\sim}20$ ppm. These results suggest that the phytoprotective effects of uniconazole are related to its role of increasing activities of free radical scavengers such as POD and SOD, in addition to growth-retardation as an anti-gibberellin.

  • PDF

A Study on the Trial Manufacture and Characteristics of Lamp Type Ozonizer (Lamp 형 오존발생기의 시작 및 특성에 관한 연구)

  • Kim, Sang-Ku;Song, Hyun-Jig;Kang, Cheon-Su;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.6
    • /
    • pp.62-72
    • /
    • 1996
  • In this paper, ozonizer using U-type lamp(Olamp) has been designed and manufactured, which can perform a role of lighting source and ozonizer by using photo and chemical methods. The discharge, spectrum, illuminance, ozone concentration, ozone generation, ozone yield and sterilization characteristics of Olamp have been studied. The important conclusions obtained from this paper can be summa'||'&'||'not;rized as follows. As a result of spectrum characteristics for Olamp, ultraviolet ray of a short wave'||'&'||'not;lengths and a visible ray are radiated. The illuminance of Olamp was found to be useful for "color distinctive and intermittent works in the dark working spaces" in accordance with KS A 3011. The ozone concentration of gaseous phase is inversely proportional to quality of supplied gas. Also, ozone conce tration and generation of gaseous phase are rised more commercial oxygen gas than those trial air gas for constant quality of supplied gas. Ozone generation and ozone yield of gaseous phase are proportion'||'&'||'not;al to ozone concentration of gaseous phase. The characteristics of liquid ozone concentration at distilled water are proportional to circulating velocity of fermentation chamber and ozone concentration of gas'||'&'||'not;eous phase. As a result, the sterilization characteristics of Escherichia coli have been obtained more than 97[ % J.

  • PDF

Evaluation of Oxidation System for Metal Oxide Thin Film (금속 산화물 박막 제작을 위한 산화 시스템의 평가)

  • 임중관;김종서;박용필
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.590-593
    • /
    • 2003
  • Ozone is a strong and useful oxidizing gas for the fabrication of oxide thin films. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Crone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure. We found the decomposition in the ozone concentration negligible if the condensed ozone is transferred from the ozone condensation system to the film growth chamber within a few minutes.

  • PDF

Use of Hydrogen Peroxide with Ozone to Simultaneously Reduce MIB and Quench Ozone Residual in Existing Water Treatment Plants Sourcing Water from the Han River (한강을 원수로 하는 오존/과산화수소 고도정수처리공정에서의 MIB제거 및 잔류오존 농도에 관한 연구)

  • McAdams, Stephen R.;Koo, Bon Jin;Jang, Myung Hoon;Lee, Sung Kyoo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.704-716
    • /
    • 2012
  • This paper provides a detailed account of pilot testing conducted at South Lake Tahoe (California), the Ddukdo (Seoul) water treatment plant (WTP) and the Bokjung (Seongnam) WTP between February, 2010, and February, 2012. The objectives were first, to characterize the reactions of ozone with hydrogen peroxide (Peroxone) for Han River water following sand filtration, second to determine empirical ozone and hydrogen peroxide doses to remove a taste-and-odor surrogate 2-methylisoborneol (MIB) using an advanced oxidation process (AOP) configuration and third, to determine the optimum dosing configuration to reduce residual ozone to a safe level at the exit of the process. The testing was performed in a real-time plant environment at both low- and high seasonal water temperatures. Experimental results including ozone decomposition rates were dependent on temperature and pH, consistent with data reported by other researchers. MIB in post-sand-filtration water was spiked to 40-50 ng/L, and in all cases, it was reduced to below the specified target level (7 ng/liter) and typically non-detect (ND). It was demonstrated that Peroxone could achieve both MIB removal and low effluent ozone residual at ozone+hydrogen peroxide doses less than those for ozone alone. An empirical predictive model, suitable for use by design engineers and operating personnel and for incorporation in plant control systems was developed. Due to a significant reduction in the ozone reaction/decomposition at low winter temperatures, results demonstrate the hydrogen peroxide can be "pre-conditioned" in order to increase initial reaction rates and achieve lower ozone residuals. Results also indicate the method, location and composition of hydrogen peroxide injection is critical to successful implementation of Peroxone without using excessive chemicals or degrading performance.

Variation of Stratospheric Ozone above Seoul during Winter 2002 (2002년 겨울의 서울 상공의 오존농도변화)

  • 박인희;가수현;김경희;오정진
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.444-446
    • /
    • 2002
  • 오존은 성층권에 대부분 존재하며, 25-30km부근에서 최대 밀도를 이루고 있다. 오존층이 자외선과 그 밖의 태양복사에너지를 흡수함에 따라 성층권의 열의 근원이 되어 지구 대기 순환에 영향을 준다. 즉, 오존층이 기후변화와 밀접한 관련을 가지므로 지구의 동식물들은 그 영향을 받게 된다. 그러나 1980년대 들어서 남극에서 오존홀이 발견되고, 이 오존홀이 계속 커진다면 피해가 증가할 것이다 이 같은 상황으로 볼 때 오존의 대한 연구 필요성은 크다고 할 수 있다. (중략)

  • PDF

The Analysis of the Nocturnal Ozone Variations over Kangreung and Wonju (강릉과 원주지역의 야간 오존 변화에 대한 분석)

  • Kim, Hyun-Sook;Lee, Hyun-Jin;Kim, Jae-Hwan
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.474-483
    • /
    • 2004
  • This paper analyzed the characteristics of daily ozone variations over Kangreung and Wonju. It was found that the diurnal cycle of ozone over Wonju has a primary ozone peak in the afternoon and a minimum around sunrise, which is a typical diurnal ozone cycle observable in the urban area. However, the cycle over Kangreung shows a primary peak in the afternoon and secondary peak around 3 a.m. The amounts of ozone in the secondary peak is occasionally higher than that in the primary peak. This nocturnal ozone peak is frequently observed year-round, and the highest frequency and extent are observed in spring. The possible cause of this nocturnal ozone increase was investigated using meteorological parameters and the HYSPLIT trajectory model. It was found that the nocturnal ozone peak is highly correlated with strong wind speed, which has led to positive temperature anomaly. The trajectory model revealed that when the secondary peak occurred, the air was originated from the west and a sinking motion subsequently followed. These findings suggested that when the westerly wind is strongest in spring, the polluted airs from urban areas are transported to the upper boundary layer over Kangreung area. In the case of strong wind during the night, nocturnal ozone peaks were produced by active vertical mixing between lower boundary and upper boundary layers.

Transport of Ozone in Downwind Area from Seoul Metropolitan (수도권 풍하 지역으로의 오존의 수송에 관한 연구)

  • 이종범;송은영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.351-352
    • /
    • 2003
  • 오존은 1차 오염물질과는 다르게 광화학 반응에 의한 2차 오염물질이기 때문에 전구물질이 배출되는 지역에서 풍하측으로 수송되어 발생하는 특징이 있다. 따라서 본 연구에서는 수도권 및 강원, 충북의 오존농도자료를 이용하여 대도시에서 풍하지역으로 오존이 수송되는 현상을 분석하고자 한다. (중략)

  • PDF