• Title/Summary/Keyword: 오염 지수

Search Result 542, Processing Time 0.022 seconds

Spatial Distributions of the Ambient Levels of Air Pollutants in Seoul Metropolitan Area (대기오염도의 공간적 분포 변화 분석 -수도권 지역을 대상으로-)

  • Kwon, Oh Sang;An, Donghwan;Kim, Wonhee
    • Environmental and Resource Economics Review
    • /
    • v.13 no.1
    • /
    • pp.83-117
    • /
    • 2004
  • This study investigates the spatial distributions of the ambient levels of air pollutants ($SO_2$, $NO_2$, $O_3$, CO, and PM) in Seoul metropolitan area using the data obtained by the air pollution observation stations. This study estimated a non-parametric kernel density function and two types of inequality indices, Gini and Entropy. Our estimation results show that the degree of inequality in spatial distribution of air pollution, in general, tends to be stable or slightly decreasing for the period of 1990~2001. In addition, we found that there are significant dynamics of air pollution levels in terms of spatial ranking.

  • PDF

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.

Assessing Groundwater Vulnerability Using DRASTIC Method and Groundwater Quality in Changwon City (DRASTIC과 지하수 수질에 의한 창원시 지하수 오염취약성 평가)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Moo-Jin;Kim In-Soo;Hwang Han-Seok
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.631-645
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in industrial and residential/commercial areas of the city of Changwon, using DRASTIC technique and groundwater data. The DRASTIC technique was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. Mostly the industrial area has higher DRASTIC indices than the residential/commercial area. However, a part of the residential/commercial area having much groundwater production and great drawdown is more contaminated in groundwater than other industrial and the residential/commercial areas even if it has lowest DRASTIC indices in the study area. It indicates that groundwater contamination in urban areas can be closely related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is as low as 0.40. On the other hand, the correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well distribution density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other human-made factors such as groundwater withdrawal rate and well distribution density per unit area as well as the existing seven DRASTIC factors.

Groundwater Quality and Contamination Characteristics Associated with Land Use in Ulsan Area (울산지역 토지이용도에 따른 지하수 수질 및 오염특성)

  • Lee, Byeong-Dae;Yun, Uk;Sung, Ig-Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.78-91
    • /
    • 2007
  • The groundwater chemistry is heavily influenced by land use. This study has investigated the groundwater quality and contamination characteristic associated with land use. Contamination index ($C_d$) was estimated for evaluating and areal distribution of groundwater contamination degree. Groundwater samples collected from 216 locations in the study area show great variability in chemical composition. Electrical conductance ranges from 100 to $31,360\;{\mu}S/cm$. The pH values are between 4.6 (acidic) and 8.57 (weak alkaline). The water types predominantly represent the $Ca-HCO_3$ and $Ca-Na-HCO_3$ types, whereas, in the residential and business areas, the water type is shifted to (Na, Ca)-Cl type with rich concentration of Cl. The $C_d$ values of the study area range from 1.1 to 117.6 with a mean of 9.56.

Environmental Assessment of the Shihwa Lake by using the Benthic Pollution Index (저서오염지수(BPI)를 이용한 시화호 환경평가)

  • Lee, Jae-Hac;Park, Ja-Yang;Lee, Hyung-Gon;Park, Heung-Sik;Kim, Dong-Sung
    • Ocean and Polar Research
    • /
    • v.25 no.2
    • /
    • pp.183-200
    • /
    • 2003
  • In order to assess the ecological changes induced by organic pollutants of the Shihwa Lake, BPI (Benthic Pollution Index) based on the benthic faunal community was employed. It was modified from Infaunal Trophic Index (ITI), and recommended as a pollution detecting method for the environmental assessment. The BPI values were calculated from the benthos data, which were collected for three terms: in 1980, before the Shihwa Lake was built up; in 1994-1997, which the Shihwa Lake was completely isolated from the outer seawater; in 1997-1999, after inflow of the outer seawater. Since the Shihwa Dike was constructed in February 1994, the pollution intensity of the lake had been increased from the narrow and inner part of the former Gyeonggi Bay and spread fast along the coast line of the Shihwa Lake. Then, in 1996 it showed the very high BPI levels all around the Lake. This serious polluted condition had been lasted till 1997, when the inflow of the seawater was begun. In 1998, from the nearest part of the Shihwa Gate, the BPI levels gradually became low in most area of the Lake, except its inner and narrow part. These greatly lowered BPI levels mean that the seawater inflow could be assumed to affect positively in the lake. Furthermore, BPI gave the same results from the other environmental assessment based on the abundance and the species richness of macrobenthic community. It shows that BPI could be useful as an effective method to assess the marine environment and evaluate the status of environmental conditions.

Dispersion and Enrichment of Potentially Toxic Elements of Farmland Soils from the Boeunjeil Mine Area, Korea (보은제일광산일대의 밭토양에 대한 독성원소들의 분산과 부화)

  • Yoo, Bong-Chul;Kim, Ki-Jung;Lee, Chan-Hee;Lee, Hyun-Koo
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.15-28
    • /
    • 2007
  • The study is for contaminations of major, rare earth and trace elements of the farmland soils from the Boeunjeil mine area. The results are compared with the soils of Chungjoo, Deokpyeong, Boeun and Chubu areas. Fe and S contents of the contaminated area are high relative to those from the uncontaminated areas, Chungjoo and Boeun areas. Trace elements of the contaminated area are high relative to those from uncontaminated area, Chunajoo, Deokpyeong, Boeun and Chubu areas. The trace elements ares divided into Cd, Ni, Sr, U, V, Zn and As, Co, Cu, Mo, Pb, Sb, based on these dispersion and correlation. Two groups show the positive correlation. Enrichment factor of potentially toxic elements from contaminated area is >5 value, but <4 value in the uncontaminated area. In the geoaccumulation index of the minor elements, the contaminated area has >1 value and the uncontaminated area has <1 value except Mn. Enrichment index of potentially toxic elements(As, Cd, Co, Cu, Ni, U, Zn) ranges from 0.3 to 87.0 in the contaminated area and from 0.4 to 3.9 in the uncontaminated area. Overall results show that the high contents of farmland soils for the elements(Fe, S, As, Cd, Co, Cu, Ni, U, Zn) indicate the contamination by coal-related activities.

Permeability Characteristics of Geosynthetics Vertical Barrier Connections for the Prevention of Contaminants Diffusion (오염물질 확산방지를 위한 토목섬유 연직차수벽 연결부의 투수성능 평가)

  • Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: In this study, we used hydrophilic waterstop used in geosynthetics vertical barrier system to evaluate the performance of impermeability under sealing conditions. Method: ASTM D5887 and ASTM D6766 were applied to determine the capability of the connection during the geosynthetics vertical barrier system. Hydrophilic waterstop was saturated in each solution and the weight, thickness, and volume changes were analyzed over elapsed time. Hydrophilic waterstop was installed at the geosynthetics vertical barrier system connection to evaluate the permeability characteristics. Results: As the expansion reaction time of hydrophilic waterstop increased relatively under saline conditions, the decrease in permeability also showed a smaller decrease in fresh water. Furthermore, the method of engagement of the geosynthetics vertical barrier system showed somewhat better performance of the impermeability due to the large pressure resistance caused by the roll joint type than interlock type. Conclusion: In urban pollutants, which can estimate the outflow of pollutants such as oil storage facilities and industrial complexes, proactive response technologies that can prevent the contaminant diffusion can significantly reduce the damage.

Development of Clean Air Index(CAI) for Regulatory Air Pollutants (규제대기오염물질에 대한 공기청정지수(CAI)의 개발)

  • 김창환;최금찬;전의찬;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.357-358
    • /
    • 1999
  • 대기오염에 대한 일반인의 관심이 증가되면서 이를 충족하기 위해 대기오염도 전광판, 오염 경보제, 신문 및 방송의 보고 등 여러 가지 방안이 제시되고 있다. 이들 매체를 통하여 전달되는 정보는 대개 대기오염 규제항목의 측정 실측치가 기준치와 함께 제시되어 현재 오염도가 기준을 초과하고 있는지의 여부만이 판단되고 있다.(중략)

  • PDF

A study on the reduction of eutrophication in reservior using solar-powered circulation (태양전지 물순환장치를 이용한 호내 부영양화 저감에 관한 연구)

  • Gu, Bon-Woo;Lee, Young-Shin;Oh, Dae-Min;Choi, Gun-Youl;Yang, Jong-Woon;Lee, Yeong-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.906-909
    • /
    • 2009
  • 소류지의 주변으로 농축산농가와 마을 등이 위치할 경우 지속적인 오염물질 유입과 강우시 농경지등에서 발생하는 비점오염물질 유입 등으로 부영양화의 원인이 되고 있으며, 이로 인해 식물성 플랑크톤의 이상번식으로 부영양화가 악화되고 있는 실정이다. 이에 본 연구에서는 태양전지 물순환장치를 이용하여 부영양화 저감효과를 평가하고자 한다. 소류지내에 태양전지 물순환장치를 설치 후 식물성 플랑크톤과 부영양화지수를 평가한 결과. 전체 식물성 플랑크톤 현존량의 경우 큰 변화가 나타나지 않았으나, 부영양화의 주요인 중 하나인 남조류가 제어되었으며, 부영양화지수는 가동기간이 증가함에 따라 부영양화지수가 감소하는 것으로 나타나 부영양화 방지에 있어서 효과적이라 판단된다.

  • PDF