• Title/Summary/Keyword: 예측선량

Search Result 169, Processing Time 0.022 seconds

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.

Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine (핵의학과 분배실 내의 공간선량률 측정)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • Even though the protective facility is well made with the development of medicine, the spatial dose within the radiation section could increase the exposure of the workers. The spatial dose is always present in distribution room within the Department of Nuclear Medicine, so the spatial dose of the interior distribution room is measured and analyzed for the prediction of the exposure dose. The spatial dose rate was $6.78{\pm}0.083{\mu}Sv/h$ in the $^{18}F$ distribution room of department of Nuclear Medicine, $9.248{\pm}0.013{\mu}Sv/h$ in $^{99m}Tc$, and $^{131}I$ distribution room. In addition, in case of $^{18}F$ distribution room, the yearly external exposure dose was $42.5{\mu}Sv$ when the nurse does IV in 1m in distance. It also showed that the spatial dose rate on the direction of right oblique showed higher than others by the standard of distribution window of distribution room. Therefore, the staying time of the workers should be short during distributing radiopharmaceuticals in the distribution room and the design of the distribution protection is necessary to reduce the exposure in the direction of right oblique of the protection. The utmost endeavors are required to reduce the worker's individual exposure dose while doing IV.

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators (운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구)

  • Kim, Hyeong-Jin;Chang, Byung-Uck;Byun, Jong-In;Song, Myeong Han;Kim, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.44-51
    • /
    • 2013
  • ICRP recommended that cosmic ray exposure to the pilot and cabin crew would be considered as an occupational exposure due to their relatively high exposure. Since 2012 with the Act No. 10908 (Natural radiation management), the guideline of cosmic ray exposure to the pilot was established in Korea. The applicability of the solid-state nuclear track detector for personal dose assessment of pilot and cabin crew was evaluated. Dose linearity and angle dependence of dosimeters to the neutron were evaluated by $^{252}Cf$ neutron emitting source. The track density has a good agreement with the dose ($r^2$=0.99) and highly dependent on the degree of an angular of the dosimeter to the neutron source. In addition, the dosimeters (SSNTD) were exposed to cosmic ray in an aircraft during its cruising for more than two months in collaboration with Airline Pilots Association of Korea. Although the correlation between the track density from aircraft cruising altitude and expected neutron dose is low, however RSNS dosimeter could be used for personal neutron dosimeter. For application of RSNS as a personal dosimeter for pilot and cabin crew, additional studies are required.

Study of Optimal Gamma Irradiation using Monte Carlo Simulations for the Control of Fungi on Wooden Cultural Property (목재 유물 돈궤의 미생물 제어를 위한 몬테카를로 방법을 이용한 감마선 조사 연구)

  • Yoon, Min-Chul;Chung, Yong-Jae;Kang, Dai-Ill;Kim, Ik-Joo;Kim, Gwang-Hoon;Lee, Yun-Jong;Lee, Ju-Woon;Choi, Jong-Il
    • Journal of Conservation Science
    • /
    • v.27 no.2
    • /
    • pp.127-134
    • /
    • 2011
  • In this study, there has been investigated the simulation of irradiation dose using Monte Carlo methodology and experimental substantiation for the biological control of wooden cultural property. In the evaluation of fungal contamination on wooden cultural property, Dongyae, from exhibition storage, Aureobasidium pullulans was mainly identified. But these microorganisms were completely inactivated by 20 kGy gamma irradiation. For dosimetry simulation of Dongyae, Monte Carlo methodology with MCNP was used. The real dosimetry was measured using alanin dosimeters (at 7 different points on the front plan and 7 points on the back plan). Simulated and experimental results are compared and good agreement is observed. These result shows that irradiation can offer biologic control of wooden cultural property by optimal irradiation dose through high penetration power and Monte Carlo simulation.

Radiation Dose Calculation in the Surrounding Organs during Brachytherapy of Prostate Cancer (전립선암 근접시료시 주변 장기 선량 평가)

  • Kim, Jung-Hoon;Lim, Chang-Seon;Whang, Joo-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.172-177
    • /
    • 2008
  • As a part of estimating quantitative radiation treatment doses, we produced a mathematical phantom based on the standard Korean male. Then, with the prostate as the source organ, we calculated the absorbed dose in the prostate and surrounding organs forecasted to occur during brachytherapy for prostate cancer. To simulate the procedure, we selected $^{25}I$ and $^{103}Pd$ useful in brachytherapy of the prostate as the radionucleids and made an assumption that 1 Ci of initial radioactivity is administered. As a result, we found that the prostate, as the source organ, indicated 101 Gy/Ci and 7.24 Gy/Ci, respectively, in case of $^{125}I$ and $^{103}Pd$. With the exception of the prostate, organs with high absorbed doses were found to be in the order of the penis and scrotum, sigmoid colon, testicles and the urinary bladder, which are relatively close to the prostate.

  • PDF

Dose Evaluation of the Man Adjacent to an Implanted Patient During the Prostate Cancer Brachytherapy (전립선암의 근접치료 시 이식환자에 근접한 사람의 선량평가)

  • Park, Euntae;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 2016
  • This study is fulfilled to evaluate the exposure dose nearby a patient during the brachytherapy of the prostate cancer treatment and to minimize the radiation exposure by evaluating the exposure dose of the person near the relevant implanted patient, technicians and gardians. The experiment method is used on the study is MCNPX that is stood on the basis monte-carlo method and implant the source to MIRD-type phantom in $^{192}Ir$, $^{125}I$, and $^{103}Pd$ in virtual space. For dose evaluations according to distance, the radiation dose on the patient near the corresponding implanted patient is evaluated by each distance of 30, 50, 100, 200 cm to anterior from the implanted patient. As a result, $^{192}Ir$ showed a higher dose than $^{125}I$ and $^{103}Pd$ in every distance.

Analysis of Radiolytic Products of Lipid for the Detection of Irradiated Dried Cuttle Fish (Sepia officinalis) (건 갑오징어의 방사선 조사여부를 판별하기 위한 지방분해산물 분석)

  • Kim, Jun-Hyoung;Kim, Kyoung-Su
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1072-1078
    • /
    • 2003
  • Radiation-induced hydrocarbons and 2-alkylcycolbutanones are formed from the fatty acids of irradiated fat. These radiation-induced compunds were detected by fat extraction with a Soxtec apparatus from dried cuttle fish (Sepia officinalis), isolation of hydrocarbons and 2-alkylcyclobutanones with florisil column chromatography, and identification of GC/MS. Concentration of hydrocarbons produced by -λ-irradiation depended on the composition of fatty acid in dried cuttle fish. The major hydrocarbons in the irradiated dried cuttle fish samples were pentadecane and 1-tetradecene from palmitic acid, heptadecane and 1-hexadecene from stearic acid, and 8-heptadecen and 1,7-hexadecadiene from oleic acid. Of 2-alkylcyclobutanones, 2-dodecylcyclobutanone from palmitic acid was present at the highest level in irradiated dried cuttle fish. The radiation-induced hydrocarbons and 2-alkylcyclobutanones from the irradiated dried cuttle fish were detected at 0.5 kGy and over, but not detected in the non-irradiated fish.

Calculations of ISO Narrow and ANSI X-Ray Spectra, Their Average Energies and Conversion Coefficients (ISO Narrow Series및 ANSI의 X선 스펙트럼, 평균에너지 및 선량환산인자의 이론적 계산)

  • Kim, Jang-Lyul;Kim, Bong-Whan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.129-136
    • /
    • 1995
  • In spite of the prescriptions on the reference X-ray fields given by the International Organization of Strandard(ISO) and American National Standard Institute(ANSI), the measurement of X-ray spectrum is not only time consuming but very difficult, paticularly when significant corrections have to be applied to the measured pulse-height distributions of the observed spectra. This paper describes the calculation method of ISO Narrow Series and ANSI X-ray filtered radiations by theoretical model which is modified framer's theory by target attenuation and backscatter correction. The X-ray spectra, average energies and conversion coefficients are calculated and compared with those obtained using the spectra prescribed by ISO and AMSI to assure good agreement.

  • PDF

Preparation and Characterization of Poly(vinyl alcohol)/Poly(N-vinylpyrrolidone)/Glycerin/Chitosan Hydrogels by Radiation (방사선 가교에 의해 제조된 Poly(vinyl alcohol)/Poly(N-vinylpyrrolidone)/글리세린/키토산 하이드로겔의 제조 및 특성)

  • 박경란;노영창
    • Polymer(Korea)
    • /
    • v.26 no.6
    • /
    • pp.792-802
    • /
    • 2002
  • In this study, hydrogels from mixtures of poly (vinyl alcohol) (PVA)/poly(N-vinylpyrrolidone) (PVP)/glycerin/chitosan were prepared by γ-ray irradiation and the mechanical properties such as gelation, water absorptivity, and gel strength were examined to evaluate the applicability of these for wound dressing. Then PVA:PVP was weight ratio of 6 : 4, the concentration of chitosan was 0.3 wt%, the concentration of glycerin was in the range of 0∼5 wt%t. The solid concentration of PVA/PVP/glycerin/chitosan solution was 15 wt%. Gamma irradiation doses of 25, 35, 50, and 60 kGy were exposed to a mixture of PVA/PVP/glycerin/chitosan to evaluate the effect of irradiation dose. Gel content and gel strength increased as glycerin concentration in PVA/PVP/glycerin/chitosan decreased, and as irradiation dose increased. Swelling degree increased as glycerin concentration in PVA/PVP/glycerin/chitosan increased, and as irradiation dose decreased. The glycerin in PVA/PVP/glycerini/chitosan hydrogel prevented the transformation of shape. These hydrogel dressings had better curing effect than vaseline gauge.