• Title/Summary/Keyword: 예상환경온열감

Search Result 34, Processing Time 0.02 seconds

Characteristics of thermal comfort for artificial environment experiment in summer (하계 인공환경실험에서의 온열쾌적특성)

  • 박종일;김경훈;홍희기;민병일;김창주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.368-377
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate(Electrocardiogram), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at SE $T^{*}$ 24.7$^{\circ}C$, -0.82<PMV<0.93, subject's clothing(0.41c1o)and the difference of skin temperature was found at the calf area as air temperature changes. At low SE $T^{*}$, heart rate was decreased and at high SE $T^{*}$, heart rate was increased but there was no change EEG(keeping $\alpha$-wave).wave).

  • PDF

Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer (여름철 사무실내 온열환경 특성 및 쾌적성 평가)

  • Lee, C.H.;Bae, G.N.;Choi, H.C.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) (개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가)

  • 최익순;정광섭;박영철;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

Development of Comfort Sensing System for Human Environment (실내 환경의 쾌적도 측정시스템 개발)

  • Kang, Jeong-Ho;Lee, Jae-Yong;Kim, Woo-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.317-321
    • /
    • 2006
  • 본 연구는 웰빙 환경 조성에 적합한 습도센서, 온도센서와 기류센서를 이용한 쾌적도 측정시스템에 관한 것이다. 이 측정시스템이 나타내는 쾌적도는 기류와 온도에 민감하게 나타났다. 시스템을 위한 온도와 습도 일체형 센서와 기류센서를 설계 및 제작하고, 마이크로 컨트롤러에서 센서 신호를 측정하여 ISO7730에서 나타내는 예상온열 감지수(PMV)와 쾌적감 지수(CSV)를 계산하고, 각각의 계산 값을 LCD에 표시하도록 하였다. 인위의 환경에서 실험한 결과, 본 시스템이 공기조화시스템, 자동차 기류조정시스템, 가정과 사무실 병원 등의 많은 분야에 적용이 될 수 있음을 알 수 있었다.

  • PDF

Performance and Applicability of PMV-based and TS-based Building Thermal Controls (PMV, TS 기준 건물 열 환경 제어법의 성능 및 적용성 분석)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.430-440
    • /
    • 2011
  • The purpose of this study was to investigate the interactions between the thermal factors in existing thermal control methods and to find out the control logic that can create more comfortable thermal conditions. For it, four thermal control logics were developed:conventional temperature-based control; temperature-based and humidity-based control; PMV-based control; and TS-based control. Their performance was comparatively tested in the U.S. typical 5-story office building in two climate zones (Detroit, Michigan and Miami, Florida) for two seasons (winter and summer) incorporating IBPT (International Building Physics Toolbox) and Matlab/Simulink. Analysis on the thermal conditions and energy efficiency revealed that each control logic created comfortable conditions for their respective target, i.e., temperature, humidity, PMV or TS, but uncomfortable for others (e.g., temperature-based control logic maintained PMV or TS uncomfortably or vise versa). In addition, energy efficiency was significantly different by logics. In conclusion, it can be said that the overall thermal comfort can be improved by the adoption of the PMV and TS as a target variable and their economical benefits are expected in the hotter climate zones with the reduced cooling and dehumidifying energy consumptions.

Simulation Analysis of Urban Heat Island Mitigation of Green Area Types in Apartment Complexes (유형별 녹지 시뮬레이션을 통한 아파트 단지 내 도시열섬현상 저감효과 분석)

  • Ji, Eun-Ju;Kim, Da-Been;Kim, Yu-Gyeong;Lee, Jung-A
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.3
    • /
    • pp.153-165
    • /
    • 2023
  • The purpose of this study is to propose effective scenarios for green areas in apartment complexes that can improve the connection between green spaces considering wind flow, thermal comfort, and mitigation of the urban heat island effect. The study site was an apartment complex in Godeok-dong, Gangdong-gu, Seoul, Korea. The site selection was based on comparing temperatures and discomfort index data collected from June to August 2020. Initially, the thermal and wind environment of the current site was analyzed. Based on the findings, three scenarios were proposed, taking into account both green patches and corridor elements: Scenario 1 (green patch), Scenario 2 (green corridor), and Scenario 3 (green patch & corridor). Subsequently, each scenario's wind speed, wind flow, and thermal comfort were analyzed using ENVI-met to compare their effectiveness in mitigating the urban heat island effect. The study results demonstrated that green patches contributed to increased wind speed and improved wind flow, leading to a reduction of 31..20% in the predicted mean vote (PMV) and 68.59% in the predicted percentage of dissatisfied (PET). On the other hand, green corridors facilitated the connection of wind paths and further increased wind speed compared to green patches. They proved to be more effective than green patches in mitigating the urban heat island, resulting in a reduction of 92.47% in PMV and 90.14% in PET. The combination of green patches and green corridors demonstrated the greatest increase in wind speed and strong connectivity within the apartment complex, resulting in a reduction of 95.75% in PMV and 95.35% in PET. However, patches in narrow areas were found to be more effective in improving thermal comfort than green corridors. Therefore, to effectively mitigate the urban heat island effect, enhancing green areas by incorporating green corridors in conjunction with green patches is recommended. This study can serve as fundamental data for planning green areas to mitigate future urban heat island effects in apartment complexes. Additionally, it can be considered a method to improve urban resilience in response to the challenges posed by the urban heat island effect.

Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Winter (겨울철 사무실내 온열환경 특성 및 쾌적성 평가)

  • Bae, G.N.;Lee, C.H.;Lee, C.S.;Choi, H.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.310-318
    • /
    • 1995
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 138 occupants were questioned to evaluate Korean thermal comfort in office building in winter. Thermal sensation was estimated by using PMV(Predicted Mean Vote) and ET*(New Effective Temperature) indices. Comparing present experimental result with international standards and that of other research, Korean thermal responses were discussed. Seasonal difference between summer and winter was also discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained; TSV=0.432ET*-8.814 and neutral temperature is $20.4^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $19.4{\sim}22.4^{\circ}C$.

  • PDF

A study on characteristics of thermal comfort for artificial environmental experiment in winter (동계 인공환경실험에 의한 온열쾌적특성 연구)

  • 박종일;김경훈;정성일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.721-731
    • /
    • 1998
  • Recently, many researchers are studying the relation between thermal environment and human comfort. The purpose of this study was to obtain basic data which are necessary to determine the thermal comfort sensation and physiological responses for men in winter indoor environment. From January to February 1998, subject experiment was 40 times proceeded under twenty different conditions of air temperature and relative humidity with early-twenty male university students. We examined subjective evaluation, Electrocardiogram(ECG), Electroencephalogram(EEG) of subjects. The results of this study can be summarized as follows : The comfort zone of people in winter was achieved at Standard new effective temperature($SET^*$) $ 25.2^{\circ}C$, PMV range was obtained by Fanger's statistical calculation was -0.27<PMV<+0.62, TSV range obtained subjects vote was -0.76<TSV<+0.36. The largest difference of skin temperature was found at the calf area as air temperature changes. vote rate of human body presented calflongrightarrowheadlongrightarrowforearmlongrightarrowchestlongrightarrowabdo men in turn. Heart rate was decreased at low $SET^*$ and heart rate was increased at high $SET^*$ But there was no change at EEG.

  • PDF

The Changes of Psychological and Physiological Emotional Responses According to Change of the Index of Predicted Mean Vote (PMV) due to Air Conditioning Types (공조방식에 의한 예상 온열감 반응(PMV) 변화에 따른 심리/생리적 감성반응의 변화)

  • Kim, Bo-Seong;Min, Yoon-Ki;Min, Byung-Chan;Kim, Jin-Ho
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.645-652
    • /
    • 2011
  • This study examined changes of both psychological and physiological emotional responses according to change of the PMV (predicted mean vote) in the heating and the cooling air conditions. For this purpose, the changes of PMV were induced by the heating and cooling operations of the HVAC (heating, ventilation, and air conditioning) systems. In addition, positive/negative and arousal/relaxation were measured as the participant's psychological emotional responses, and HR (heart rate) was measured as the participant's physiological emotional responses. As a result, in same range of the PMV, both psychological and physiological emotional-responses were changed by air conditioning. It is suggested that occupant's emotional responses would depend on the operational conditions of heating and cooling in indoor thermal environments, and both psychological and physiological emotional response should be considered when occupants try to match the indoor thermal environments to their thermal expectations.

  • PDF

Evaluation of Thermal Performance in a Stadium with Air Circulation System (공기순환 시스템이 설치된 경기장 공간의 열성능 평가)

  • Kim, Kyung-Hwan;Im, Yoon-Chul;Lee, Jae-Heon;Oh, Myung-Do;Park, Myung-Sig;Lee, Dae-Woo;Park, Young-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.170-174
    • /
    • 2001
  • In this paper, CFD technique has been used at design stage to predict space air distribution in a cycle stadium with air circulation system. An air circulation flow of 0.67 rev./min was observed at computed results in the stadium space with and without air circulation system. Comparing the thermal comfort of the two models with or without air circulation system showed that the thermal environment in the former was superior in the latter. Energy savings could be achieved for the model with air circulation due to its lower air inflow temperature.

  • PDF