• Title/Summary/Keyword: 영하 온도

Search Result 112, Processing Time 0.034 seconds

A Study of the Development of a Korea Wind Chill Temperature Index (I) - Focusing on the Distribution of Existing Wind Chill Temperature Index and Sensitivity Analysis of Model - (한국형 체감온도지수 개발연구(I) -기존 체감온도지수 분포 및 민감도 분석 -)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Eun-Byul;Park, Gil-Un
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.878-890
    • /
    • 2007
  • This study aimed to provide a fundamental basis for the development and promotion of a Korea windchill temperature index model in the field of human biometeorology. For this, a sensitivity model currently being used by KMA (Korea Meteorological Administration) was analyzed. The results of the analysis showed that the Korean peninsula could be divided into the urban area, the coastal/island area, the inland area, and the mountain area. The average temperature was highest in the coastal/island area, while it was lowest in the mountain regions. The lowest temperature in the urban and coastal/island areas was 20 degrees below zero and that in the inland and mountain regions were 30 degrees below zero. As for wind speed, both average and maximum wind speed were highest in the coastal/island area. The distribution of temperature and wind speed in winter was similar to that of the entire period. The results of the JAG/Tl and Missenard model sensitivity showed that temperature tends to have more influence on sensitivity than any other factors. In sub-zero temperature, however, the influence of wind speed tends to increase.

Development of Forms for Cold Weather Concrete by Combination of Insulation (단열재 조합에 의한 한중콘크리트용 거푸집 개발)

  • Han, Cheon-Goo;Oh, Seon-Kyo;Sin, Dong-An;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.392-399
    • /
    • 2003
  • This paper discusses the validities of insulating curing of cold weather concreting at early stage by applying insulation forms. Tests were carried out using modified insulating form combining existing insulating form and various other insulations in order to develop improved insulation form. Temperature history of concrete using various insulating forms and insulation was measured to determine most effective combination of insulting form. According to results, as for the wall form, under the curing temperature of $-10^{\circ}C$, the temperature of concrete using Euro form drops sharply before 24 hours and lasts below $0^{\circ}C$ for 7 hours. The temperature of concrete using the form combining Polypropylene panel, styrofoam and plywood panel keep above $0^{\circ}C$. And, it is confirmed that the form mentioned above has a favorable effects on enhancing strength development of concrete and the cost to make the forms shows more reasonable than that of existing forms. However, as for the combination methods of insulation form for slab, which is composed of insulating form at the bottom of slab and various surface curing materials at the top of slab, in case of exposed condition at the top of slab, temperature history of concrete goes below $0^{\circ}C$ after 10 hours. In case of the combination of vinyl sheet and curing blanket, it drops below $0^{\circ}C$ after 42 hours. However, in case of the combination of vinyl, styrofoam and curing blanket, it does not go below $0^{\circ}C$ until 55 hours. Accordingly, compared to the case of exposure and the combination of vinyl and curing blanket, it indicates that the combination mentioned above has more effective insulating performance.

Development of Measurement System for Friction Coefficient between fabric surface and fingertip (직물표면과 손끝사이의 마찰계수 측정기술개발)

  • 권영하;권현준;박경희
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.404-406
    • /
    • 2003
  • 직물의 촉각은 인간의 피부와 직물사이의 마찰력, 온도, 진동 등의 물리적, 역학적인 현상에 의해서 느끼게 된다. 그 중에서 마찰력은 질감을 결정하게 하는 가장 중요한 요소이다. 지금까지의 연구는 직물과 금속 등의 다른 물질 또는 직물과 직물사이에서 나타나는 마찰력을 측정하였으나, 본연구에서는 직접 손끝으로 문지를 때 나타나는 마찰력을 실시간으로 측정할 수 있도록 다축 로드셀등을 이용한 측정장치를 개발하였다. (중략)

  • PDF

Temperature Effect on the Compaction Characteristic of Cohesionless Soil (온도에 따른 사질토의 다짐 특성)

  • Lee, Kicheol;Ji, Subin;Kim, Hobi;Kim, Dongwook
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • Among several factors controlling soil compaction, temperature is the factor that varies with region and season. Although earthwork is performed in many projects in the cold regions of the earth, studies on quantifying soil compaction associated with temperature are limited. This experimental study investigates the temperature effect on the soil compaction of cohesionless soil. Jumunjin sand was selected for the tests to represent cohesionless clean sand, which is widely used as an engineering fill at petrochemical projects such as northern Alberta of Canada and Russia. The laboratory test program consists of performing a series of standard proctor tests varying temperature of soil samples ranging from $-10^{\circ}C$ to $17^{\circ}C$. Test results indicate that soil specimen volume expansion occurred from bulking and its range was 0% to 6% with zero above temperature. For increasing temperature from $0^{\circ}C$ to $17^{\circ}C$, water content corresponding to maximum volume (minimum dry unit weight) was decreased and water content corresponding to minimum volume (maximum dry unit weight observed after reaching minimum dry unit weight) was slightly increased with increasing temperature. In zero below temperature, dry unit weight gradually decreased with increasing water content. In this case, no bulking effect was found and soil specimen volume increased due to the higher unit volume of ice.

A Study on the Minimization of Ground Resistance Variance by Temperature and Freezing of Ground (온도변화 및 토양동결에 의한 접지저항값 변화 최소화에 관한 연구)

  • Kim, Geun-Hwan;Wong, Yoon-Chan;Park, Jung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.73-73
    • /
    • 2006
  • 본 연구의 목적은 배전선로 접지극의 온도변화 및 토양동결 상태에 따른 접지저항값의 변화를 관찰하고, 영상과 영하의 온도와 접지저항값 변화의 상관관계를 분석하여 접지저항값 변화를 최소화하는 데 있다. 온도변화에 따른 접지저항값 변화의 최소화를 이루기 위하여 접지극과 토양의 접촉저항을 최소화하는 방안을 연구 하였으며, 이를 현장에 적용하여 검증한 결과, 접지저항값의 변화가 최소화되는 우수한 성과를 거양하여 각종 접지공사의 설계시 활용할 수 있도록 하였다.

  • PDF

Bridge Road Surface Frost Prediction and Monitoring System (교량구간의 결빙 예측 및 감지 시스템)

  • Sin, Geon-Hun;Song, Young-Jun;You, Young-Gap
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.42-48
    • /
    • 2011
  • This paper presents a bridge road surface frost prediction and monitoring system. The node sensing hardware comprises microprocessor, temperature sensors, humidity sensors and Zigbee wireless communication. A software interface is implemented the control center to monitor and acquire the temperature and humidity data of bridge road surface. A bridge road surface frost occurs when the bridge deck temperature drops below the dew point and the freezing point. Measurement data was used for prediction of road surface frost occurrences. The actual alert is performed at least 30 minutes in advance the road surface frost. The road surface frost occurrences data are sent to nearby drivers for traffic accidents prevention purposes.

Application of Insulation Curing Method with Double Bubble Sheets Subjected to Cold Weather (이중 버블시트를 이용한 단열양생공법의 한중시공 적용 사례)

  • Hong, Seak-Min;Lee, Chung-Sub;Kim, Jong;Jeon, Chung-Kun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1001-1004
    • /
    • 2008
  • This study reviewed the results of utilization of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double layer bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and $10^{\circ}C$ even in case outside temperature drops $10^{\circ}C$ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than $6^{\circ}C$, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

An Experimental Study of the King Sejong Station and Siberian Frozen Soils (세종기지 및 시베리아 흙의 동결특성 시험)

  • Kim, Youngchin;Shin, Jaewon;Son, Seungmo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.5-12
    • /
    • 2009
  • Soil samples from the King Sejong Station in Antarctic and Vladivostok were tested in the laboratory and specific gravity, compaction curve, grain size distribution were determined. The effect of temperature change on the thermal conductivity, unfrozen water content, compressive strength were investigated. In addition, the change of tensile strength with temperature of the soil from Vladivostok was measured. Samples for the compressive strength test and tensional strength test were prepared in a mould with a fixed volume to prevent swelling. Also the effects of temperature and water content change on those strength were compared. Results from the thermal conductivity test showed that thermal conductivity values for both soils was larger at temperatures below freezing than those above freezing. The unfrozen water content dropped rapidly within a temperature range of $0{\sim}-5^{\circ}C$ and then gradually decreased further $-20^{\circ}C$. Compressive strength test results showed various stress/deformation curves with a change in water content. Sandy soil of the King Sejong Station had a much larger strength than ice at an identical temperature, while clayey soil of Vladivostok had a smaller strength than ice in the initial stage, but showed a larger strength at temperatures belows $-15^{\circ}C$. Tensile strength tests revealed an increase in the strength with a decreasing temperature.

  • PDF

Temperature History of the Concrete Corresponding to Various Curing Sheets in the Low Temperature (저온환경에서의 양생시트 변화에 따른 콘크리트의 온도이력 특성)

  • Baek, Dae-Hyun;Hong, Seak-Min;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.781-784
    • /
    • 2008
  • In this paper, insulating effect and strength development of concrete under low temperature are reported varying curing sheets. According to test results, in temperature -5$^{\circ}$C concrete subject to exposure and air cap condition, result in a frost damage at early age by a fall of below zero temperature. Mean while, the combination of PE film and non-woven fabric maintained around 3 $^{\circ}$C within first 24 hours since placement. For double bubble sheets, concrete temperature maintained above 7$^{\circ}$C due to its excellent heat insulating capability. As a result of core strength test, strength of specimens cured with viny + non-woven fabric and double bubble sheets had higher strength than strength of other specimens due to good heat insulation effect at early age.

  • PDF

A LPG Dispensing Control System based on a 16-bit Microprocessor (16-bit 마이크로프로세서로 구현한 LPG 충전 제어 시스템)

  • 이상훈;홍남관
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2002
  • In this paper, a POS interfacing and temperature compensable LPG dispensing control system(LDCS) has been developed. A LDCS includes a 16-bit 80C196 microprocessor, RAM, ROM, video driver, and programmable peripheral devices. Based on gas flow encoding pulse, temperature-voltage conversion values and apparatus calibration values, the LDCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with a 10-bit A/D conversion and its range is from +7$0^{\circ}C$ to -3$0^{\circ}C$ with a 0.5$^{\circ}C$ resolution.

  • PDF