• Title/Summary/Keyword: 영역검출

Search Result 3,099, Processing Time 0.035 seconds

Robust Audio Watermarking Algorithm with Less Deteriorated Sound (음질 열화를 줄이고 공격에 강인한 오디오 워터마킹 알고리듬)

  • Kang, Myeong-Su;Cho, Sang-Jin;Chong, Ui-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.653-660
    • /
    • 2009
  • This paper proposes a robust audio watermarking algorithm for copyright protection and improvement of sound quality after embedding a watermark into an original sound. The proposed method computes the FFT (fast Fourier transform) of the original sound signal and divides the spectrum into a subbands. Then, it is necessary to calculate the energy of each subband and sort n subbands in descending order corresponding to its power. After calculating the energy we choose k subbands in sorted order and find p peaks in each selected subbands, and then embed a length m watermark around the p peaks. When the listeners hear the watermarked sound, they do not recognize any distortions. Furthermore, the proposed method is robust as much as Cox's method to MP3 compression, cropping, FFT echo attacks. In addition to this, the experimental results show that the proposed method is generally 10 dB higher than Cox's method in SNR (signal-to-noise ratio) aspect.

Development of Laser Power Meter Calibration System with 12-diode Laser Sources (12개 다이오드 레이저를 활용하는 레이저 복사출력계 교정시스템 개발)

  • Kanghee Lee;Jae-Keun Yoo;In-Ho Bae;Seongchong Park;Dong-Hoon Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.2
    • /
    • pp.61-70
    • /
    • 2024
  • We demonstrate a laser power meter calibration system based on 12-diode laser sources coupled to single-mode fibres in a wavelength range from 400 to 1,600 nm. In our system, three laser power controllers ensure that the output power uncertainty of all laser sources is less than 0.1% (k=2). In addition, all laser beams are adjusted to have similar beam sizes of approximately 2 mm (1/e2-width) at the measurement position to minimise unmeasured laser power on a detector. As a reference detector, we use an integrating sphere combined with silicon and indium gallium arsenide photodiodes to minimise the non-uniformity and non-linearity of responsivity. The minimum uncertainty of the calibration system is estimated to be 1.1% (k=2) for most laser wavelengths.

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

Infrared Characteristics of Some Flash Light Sources (섬광의 적외선 특성 연구)

  • Lim, Sang-Yeon;Park, Seung-Man
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • To effectively utilize a flash and predict its effects on an infrared device, it is essential to know the infrared characteristics of the flash source. In this paper, a study of the IR characteristics of flash light sources is carried out. The IR characteristics of three flash sources, of which two are combustive and the other is explosive, are measured with an IR characteristic measurement system over the middle- and long-wavelength infrared ranges. From the measurements, the radiances over the two IR ranges and the radiative temperatures of the flashes are extracted. The IR radiance of flash A is found to be the strongest among the three, followed by those of sources C and B. It is also shown that the IR radiance of flash A is about 10 times stronger than that of flash B, even though these two sources are the same type of flash with the same powder. This means that the IR radiance intensity of a combustive flash source depends only on the amount of powder, not on the characteristics of the powder. From the measured radiance over MWIR and LWIR ranges for each flashes, the radiative temperatures of the flashes are extracted by fitting the measured data to blackbody radiance. The best-fit radiative temperatures (equivalent to black-body temperatures) of the three flash sources A, B, and C are 3300, 1120, and 1640 K respectively. From the radiance measurements and radiative temperatures of the three flash sources, it is shown that a combustive source radiates more IR energy than an explosive one; this mean, in turn, that the effects of a combustive flash on an IR device are more profound than those of an explosive flash source. The measured IR radiances and radiative temperatures of the flash sources in this study can be used to estimate the effects of flashes on various IR devices, and play a critical role for the modeling and simulation of the effects of a flash source on various IR devices.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Effects of SNP Markers of the Apolipoprotein E (APOE) Gene on Meat Quantity and Quality Traits in Korean Cattle (한우 아포지단백질 E (APOE) 유전자의 SNP Marker가 육량 및 육질형질에 미치는 영향)

  • Shin, Ki-Hyun;Shin, Sung-Chul;Chung, Ku-Young;Chung, Eui-Ryong
    • Food Science of Animal Resources
    • /
    • v.29 no.1
    • /
    • pp.108-113
    • /
    • 2009
  • Apolipoprotein E (APOE) is a plasma lipoprotein in mammals and plays an important role in the transport and metabolism of lipids such as phospholipids and triglycerides. Therefore, the APOE gene could be a candidate gene controlling lipid metabolism in beef cattle. This study was performed to identify single nucleotide polymorphisms (SNP) in the APOE gene and to investigate the effects of SNP genotype on the carcass traits such as meat quantity and quality in Korean cattle. For PCR amplification, pooled DNA made from unrelated 60 individuals was prepared and primer pairs were designed based on the cDNA sequence of exon 4 region of the bovine APOE gene. A SNP was identified at position 2034 (T/C substitution) of the exon 4 region in the APOE gene. PCR-RFLP procedure with restriction enzyme ACC I was developed for determining the SNP genotype for each of a total of 309 animals with pedigree information and performance records through the national progeny testing program. The frequencies of the genotypes TT, TC and CC were 10.9, 46.9 and 42.2%. Gene frequencies were 0.344 for T allele and 0.656 for C allele. The g.2034T>C SNP genotype showed a significant effect (p<0.05) on dressing percentage and meat color, respectively. Animals with the TT genotype showed higher dressing percentage than those with the CC genotype, and TT genotype had desirable meat color compared with CC genotype. These results suggest that the g.2034T>C SNP genotype of the APOE gene may be useful as a DNA marker for meat quantity index and dressing percentage in Korean cattle.

Dielectric Properties and Ordering Structures of Pb(Fe1/2Ta1/2)O3-Pb(Fe1/2Nb1/2)O3 Solid Solutions (Pb(Fe1/2Ta1/2)O3-Pb(Fe1/2Nb1/2)O3 고용체의 유전특성 및 질서배열구조)

  • Woo, Byong-Chul;Kim, Byung-Kook;Lee, Jong-Ho;Park, Hyun-Min;Kim, Byong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.863-870
    • /
    • 2002
  • The Single phase $Pb(Fe_{1/2}Ta_{1/2})O_3$ (x=0.0∼1.0) solid solutions were successfully synthesized and their ordering structures as well as dielectric properties were investigated ${{r(Nb^{5+})=r(Ta^{5+})=0.78 {\AA},\;AW(Nb^{5+})=92.91,\;AW(Ta^{5+})=180.95}}$. While $Pb(Fe_{1/2}Ta_{1/2})O_3$ showed typical relaxor ferroelectric characteristics such as dielectric relaxation and diffuse phase transition, the sharpeness of the phase transition increased as $Ta^{5+}$ was replaced by $Nb^{5+}$ and finally $Pb(Fe_{1/2}Nb_{1/2})O_3$ showed normal ferroelectric characteristics with no dielectric relaxation. By using Raman spectroscopy, it was revealed that the $Fe^{3+}\;and\;Ta^{5+}\;of\;Pb(Fe_{1/2}Ta_{1/2})O_3$ were stoichiometrically 1:1 ordered within the short range which can be hardly probed even by TEM. Also, The degree of ordering in $Pb(Fe_{1/2}Ta_{1/2})O_3$ decreased as $Ta^{5+}$ was replaced by $Nb^{5+}$ and finally $Fe^{3+}\;and\;Nb^{5+}\;of\;Pb(Fe_{1/2}Nb_{1/2})O_3$ were completely disordered. The relaxor ferroelectric characteristics of $Pb(Fe_{1/2}Ta_{1/2})O_3$ could be correlated with the stoichiometric 1:1 ordering of B-site cations within the short range which can be hardly probed even by TEM. Also, the decrease of the relaxor ferroelectric characteristics with the replacement of $Ta^{5+}\;by\;Nb^{5+}$ could be correlated with the weakening of the ordering and the normal ferroelectric characteristics of $Pb(Fe_{1/2}Nb_{1/2})O_3$ could be correlated with the complete disordering of B-site cations.

Physicochemical Properties of Pearl Oyster Muscle and Adductor Muscle as Pearl Processing Byproducts (진주 가공부산물(육 및 패주)의 이화학적 특성)

  • Kim, Jin-Soo;Kim, Hye-Suk;Oh, Hyeun-Seok;Kang, Kyung-Tae;Han, Gang-Uk;Kim, In-Soo;Jeong, Bo-Young;Moon, Soo-Kyung;Heu, Min-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.4
    • /
    • pp.464-469
    • /
    • 2006
  • This study was conducted to evaluate a knowledge on food components of muscle and adductor muscle of pearl oyster (Pinctada fucata martensii) as pearl processing byproducts. The concentrations of mercury and chromium as heavy metal were not detected in both pearl oyster muscle and adductor muscle, and those of cadmium and lead were 0.06 ppm and 0.11 ppm in only pearl oyster muscle, respectively. Thus, the heavy metal levels of pearl processing byproducts were below the reported safety limits. The volatile basic nitrogen (VBN) content and pH of pearl oyster muscle were 11.6 mg/100g and 6.31 and those of abductor muscle were 8.6 mg/100 g and 6.33, respectively. It was concluded that pearl oyster muscle and adductor muscle might not invoke health risk in using food resource. The contents of crude protein (16.5%) and total amino acid (15,691 mg/100 g) of adductor muscle were higher than those of muscle (11.2% and 10,131 mg/100 g) and oyster (12.1% and 11,213 mg/100 g) as a control. The contents of calcium and phosphorus were 95.4 mg/100 g and 116.0 mg/100 g in muscle, 75.2 mg/100g and 148.1 mg/100 g in adductor muscle, respectively. The calcium level based on phosphorus was a good ratio for absorbing calcium. The free amino acid contents and taste values were 635.5 mg/100 g and 40.2 in muscle, and 734.9 mg/100 g and 24.1 in adductor muscle, respectively, but that (882.8 mg/100 g and 40.2) of oyster was higher than those of pearl processing byproducts. Based on the results of physicochemical and nutritional properties, pearl oyster muscle and adductor muscle can be utilized as a food resource.

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.