• Title/Summary/Keyword: 영상 대조

Search Result 679, Processing Time 0.032 seconds

The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System (의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구)

  • Kang, Sang Sik;Kim, Kyo Tae;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.589-596
    • /
    • 2019
  • X-rays used for diagnosis have a continuous energy distribution. However, photons with low energy not only reduce image contrast, but also contribute to the patient's radiation exposure. Therefore, clinics currently use filters made of aluminum. Such filters are advantageous because they can reduce the exposure of the patient to radiation. However, they may have negative effects on imaging quality, as they lead to increases in the scattered dose. In this study, we investigated the effects of the scattered dose generated by an aluminum filter on medical image quality. We used the relative standard deviation and the scatter degradation factor as evaluation indices, as they can be used to quantitatively express the decrease in the degree of contrast in imaging. We verified that the scattered dose generated by the increase in the thickness of the aluminum filter causes degradation of the quality of medical images.

Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm (가상의 단일 에너지 영상 재구성 기법을 이용한 하지 단층촬영 혈관조영술에서 말초 동맥 질환 영상 소견)

  • Jun Seong Kim;So Hyun Park;Suyoung Park;Jung Han Hwang;Jeong Ho Kim;Seong Yong Pak;Kihyun Lee;Bernhard Schmidt
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1032-1045
    • /
    • 2022
  • Peripheral arterial disease (PAD) is common in elderly patients. Lower-extremity CT angiography (LE-CTA) can be useful for detecting PAD and planning its treatment. PAD can also be accurately evaluated on reconstructed monoenergetic images (MEIs) from low kiloelectron volt (keV) to high keV images using dual-energy CT. Low keV images generally provide higher contrast than high keV images but also feature more severe image noise. The noise-reduced virtual MEI reconstruction algorithm, called the Mono+ technique, was recently introduced to overcome such image noise. Therefore, this pictorial review aimed to present the imaging findings of PAD on LE-CTA and compare low and high keV images with those subjected to the Mono+ technique. We found that, in many cases, the overall and segmental image qualities were better and metal artifacts and venous contamination were decreased in the high keV images.

The Effects of Education and Test Information Provision on Anxiety, Discomfort, and Satisfaction of Patients During Double Contrast Barium Enema (대장 조영검사에 대한 교육 및 검사정보 제공이 환자의 불안, 불편감, 검사 만족도에 미치는 영향)

  • Lee, Kyu-Hum;Lee, Jin-Yong;Lee, Moo-Sik;Bae, Seok-Hwan;Cho, Bum-Sang
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • The purpose of this study was to evaluate the effects of education and test information provision on anxiety, discomfort, and satisfaction of patients during double contrast barium enema. The experiments were conducted from October 11, 2010 to November 5, 2010. Among all patients who visited the hospital to receive colon study in the outpatient radiology clinic of one general hospital located in Seoul, a total of 50 patients fit for selection criteria were divided into an experimental group (25) and a control group (25). After providing education and test information to the experimental group, we evaluated patients' levels of anxiety and discomfort, as well as satisfaction. The experimental group and the control group had different anxiety scores: 3.76 versus 6.04 respectively (P<0.05). In addition, the levels of abdominal pain and anal pain in the experimental group were lower than those of the control group (P<0.05). Lastly, the scores of test satisfaction between two groups were 89.6 and 67.4 respectively (P<0.05). Education and test information provision about the colon study decreased the levels of patients' anxiety and discomfort and increased satisfaction level of the test.

Protective Effect of Citrus unshiu Peel Extract on Ethanol-Induced Fatty Liver in Rats (흰쥐에서 감귤과피 추출물의 알코올성 지방간 개선 작용)

  • Kim, Juyeon;Choi, In-Wook;Noh, Sang Kyu
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.2
    • /
    • pp.187-193
    • /
    • 2014
  • This study investigated whether or not Citrus unshiu peel extract (CPE) affects fat accumulation in livers of rats fed an ethanol-containing liquid diet. Initially, male Sprague-Dawley rats were housed individually in stainless steel, wire-bottomed cages with free access to a Lieber-Decarli control liquid diet. Rats were divided by body weight into three groups of eight each: one group of rats was fed the Lieber-Decarli control liquid diet devoid of ethanol (control), another was fed the Lieber-Decarli ethanol diet (ethanol), and third was fed the same ethanol diet except containing CPE. All three groups were fed their respective diets for 6 weeks. Serum and liver lipids were analyzed and liver histology performed. Body weight did not differ among the groups over the 6-wk duration. Histology images showed that CPE administration significantly improved fat accumulation in livers, which was induced by ethanol diet. Serum levels of transaminases and lipids also were reduced by CPE consumption. Taken together, the results indicate that CPE may protect ethanol-induced fatty liver by lowering fat accumulation in both the liver and blood. The protective effects of CPE appear to be due to its phenolic contents.

In Vitro Study of Tumor Seeking Radiopharmaceutical Uptake by Human Breast Cancer Cell Line MCF-7 after Paclitaxel Treatment (사람 유방암세포주 MCF-7에 Paclitaxel 처치 후 종양영상용 방사성의약품 섭취 변화에 대한 시험관내 연구)

  • Choi, Joon-Young;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.364-372
    • /
    • 2007
  • Purpose: This study was designed to investigate the cellular uptake of various tumor imaging radiopharmaceuticals in human breast cancer cells before and after paclitaxel exposure considering viable cell number. Materials and Methods: F-18-fluorodeoxyglucose, C-11-methionine, Tl-201, Tc-99m-MIBI, and Tc-99m-tetrofosmin were used to evaluate the cellular uptake in MCF-7 cells. MCF-7 cells were cultured in multi-well plates. Wells were divided into DMSO exposure control group, and paclitaxel exposure group. The exposure durations of paclitaxel with 10 nM or 100 nM were 2 h, 6 h, 12 h, 24 h, and 48 h. Results: Viable cell fraction was reduced as the concentration and exposure time of paclitaxel increased. After 10 nM paclitaxel exposure, the cellular uptake of all 5 radiopharmaceuticals was not reduced significantly, irrespective of exposure time and viable cell fraction. After 100 nM paclitaxel exposure, the cellular uptake of all 5 radiopharmaceuticals was enhanced significantly irrespective of viable cell fraction. The peak uptake was observed in experimental groups with paclitaxel exposure for 6 to 48 h according the type of radiopharmaceutical. When the cellular uptake was adjusted for the viable cell fraction and cell count, the peak cellular uptake was observed in experimental groups with paclitaxel exposure for 48 h, irrespective of the type of radiopharmaceutical. Conclusion: The cellular uptake of F-18-fluorodeoxyglucose, C-11-methionine, Tl-201, Tc-99m-MIBI, and Tc-99m-tetrofosmin did not reflect viable cell number in MCF-7 cells after paclitaxel exposure for up to 48 h.

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

Comparison of digital models generated from three-dimensional optical scanner and cone beam computed tomography (3차원 광학 스캐너와 콘빔CT에서 생성된 디지털 모형의 비교)

  • Kwon, Hyuk-Jin;Kim, Kack-Kyun;Yi, Won-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.60-69
    • /
    • 2016
  • Purpose: The objective of this study was to compare the accuracy of digital models from 3 dimentional (3D) optical scanner and cone beam computed tomography (CBCT). Materials and Methods: We obtained digital models from 11 pairs of stone casts using a 3D optical scanner and a CBCT, and compared the accuracy of the models. Results: The error range of average positive distance was 0.059 - 0.117 mm and negative distance was 0.066 - 0.146 mm. Statistically (P < 0.05), average positive distance was larger than $70{\mu}m$ and shorter than $100{\mu}m$, and that of negative distance was larger than $100{\mu}m$ and shorter than $120{\mu}m$. Conclusion: We concluded that the accuracy of digital models generated from CBCT is not appropriate to make final prostheses. However, it may be acceptable for provisional restorations and orthodontic diagnoses with respect to the accuracy of the digitalization.

Brain Atrophy and White Matter Lesions on Magnetic Resonance Imaging in Alzheimer's Disease (알쯔하이머 치매 환자의 뇌자기공명영상(腦磁氣共鳴影像)에 나타난 뇌위축(腦萎縮)과 뇌백질병변(腦白質病變)에 대한 연구)

  • Woo, Jong Inn;Kim, Ju Han
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.203-210
    • /
    • 1996
  • Objects : To investigate the relationship between the age of onset with the atrophy and the white matter hyperintensities observed in the brain MRI of Alzheimer patients. Methods : The authors measured volumetrically cortical and ventricular brain atrophy and rated semiquantitatively white matter signal hyperintensities in nine presenile and 18 senile Alzheimer patients, who were matched for dementia severity, according to NINCDS-ADRDA criteria and in age-matched 10 presenile and 11 senile control subjects. Results : Presenile Alzheimer patients showed significantly greater cortical and ventricular atrophy indices(p<0.05) but no difference in white matter hyperintensity scores compared to the age-matched control group. On the contrary, senile Alzheimer patients showed significantly greater white matter hyperintensity scores(p<0.05) but no difference in cortical and ventricular atrophy indices compared to the age-matched control group. Conclusion : An earlier onset was related to marked brain atrophy with less white matter lesions and a later onset is related to marked white matter lesions with less brain atrophy in Alzheimer's disease. Our results suggested the passible difference in the pathophysiology between the presenile and the senile-onset Alzheimer's disease.

  • PDF

Quality Characteristics of White Pan Bread with Haenaru Rice Flour (해나루쌀을 첨가한 식빵의 품질특성)

  • Ju, Hyoung-Woog;Lee, Kwang-Suck
    • Culinary science and hospitality research
    • /
    • v.22 no.2
    • /
    • pp.44-56
    • /
    • 2016
  • This study investigated the quality characteristics of white pan bread with Haenaru rice flour which is regional product of Dangjin. Haenaru rice flour was substituted 10%, 30% and 50% for each bread sample. The overall effects of Haenaru rice flour substitution on pan bread were examined by investigating fermentation rates, pH, volume, specific volume, TPA, crumbScan and colorimeter and using sensory evaluation. A control showed the highest fermentation rate by 60 min, but there was no differences among all samples except HNR50 after 60 min. The higher Haenaru rice flour content, the higher pH value of bread loaf and bread and the lower volume and specific volume of rice breads. According to TPA and crumbscan, high amounts of Haenaru rice flour substitution increased the hardness of bread and decreased fineness and elongation of bread cells. In sensory evaluation, though a control got the best texture, flavor and overall acceptance, HRF30 and HRF10 showed the best preference of appearance and taste respectively, But most of all, there were no significant differences among those samples. Consequently, the results indicate that a substitution of Haenaru rice flour for wheat flour by 30 percent will not show any decisive difference in consumer's acceptance.

A noble Sample-and-Hold Circuit using A Micro-Inductor To Improve The Contrast Resolution of X-ray CMOS Image Sensors (X-ray CMOS 영상 센서의 대조 해상도 향상을 위해 Micro-inductor를 적용한 새로운 Sample-and-Hold 회로)

  • Lee, Dae-Hee;Cho, Gyu-Seong;Kang, Dong-Uk;Kim, Myung-Soo;Cho, Min-Sik;Yoo, Hyun-Jun;Kim, Ye-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.4
    • /
    • pp.7-14
    • /
    • 2012
  • A image quality is limited by a sample-and-hold circuit of the X-ray CMOS image sensor even though simple mos switch or bootstrapped clock circuit are used to get high quality sampled signal. Because distortion of sampled signal is produced by the charge injection from sample-and-hold circuit even using bootstrapped. This paper presents the 3D micro-inductor design methode in the CMOS process. Using this methode, it is possible to increase the ENOB (effective number of bit) through the use of micro-inductor which is calculated and designed in standard CMOS process in this paper. The ENOB is improved 0.7 bit from 17.64 bit to 18.34 bit without any circuit just by optimized inductor value resulting in verified simulation result. Because of this feature, micro-inductor methode suggested in this paper is able to adapt a mamography that is needed high resolution so that it help to decrease patients dose amount.