• Title/Summary/Keyword: 영상 대조

Search Result 679, Processing Time 0.031 seconds

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

Suppression of side lobe using distance weight in spectrum of channel signal in medical ultrasound imaging system (의료용 초음파 영상 시스템에서 채널신호의 스펙트럼에서 거리 가중치를 이용한 부엽의 억제)

  • Yu Rim Lee;Mok Kun Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.203-213
    • /
    • 2023
  • In medical ultrasound imaging systems, Side lobes may appear if signals outside the imaging point are not completely removed during receive focusing. If the time signal of the side lobe overlaps with the time signal (main lobe) from the image point, it is difficult to completely remove it using filter processing in the time domain. However, In the receive focusing process, when time-channel signals are Fourier-transformed, the main lobe and side lobe signals are spatially separated in the spectral domain. Therefore, the side lobes can be suppressed by multiplying the image with magnitude weights, which are determined by the magnitudes of the main and side lobes calculated in the spectral domain. In addition, when the main lobe and the side lobe spectrum are adjacent, the distance weight was applied based on the distance between them. In a 5 MHz ultrasound imaging system using a 64-channel linear transducer, point reflector and speckle images with cysts of various brightness were synthesized and weights were applied to the ultrasound image. Using computer simulations, we confirmed that the side lobes were greatly reduced without affecting the spatial resolution in the point reflector image, and the contrast was significantly improved in the cyst image with computer simulations.

The Passport Recognition by Using Smearing Method and Fuzzy ART Algorithm (스미어링 기법과 퍼지 ART 알고리즘을 이용한 여권 인식)

  • 류재욱;김광백
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.37-42
    • /
    • 2002
  • 현행 출입국 관리는 사용자가 여권을 제시하면, 여권을 육안으로 검색하고 수작업으로 정보를 입력하여 여권의 데이터 베이스와 대조하였다. 이러한 종래의 출입국 관리 시스템은 출입국 심사 시간이 길어 출입국자에 불편을 제공하고 출입국 부적격자에 대한 정확한 검색이 이루어지지 않아 체계적으로 관리하기가 어려웠다. 이리한 종래의 문제점을 개선하기 위해 영상 처리와 문자 인식을 이용한 여권 인증 시스템을 제안한다. 된 논문에서는 여권 영상에 대해 소벨 연산자와 스미어링 기법 그리고 윤곽선 추적 알고리즘을 이용하여 사진영역, 코드 영역 및 개별 코드 문자를 추출하고 개별 코드 문자 인식은 기존의 퍼지 ART를 개선하여 적용한다. 다양한 국내 여권 영상에 대해 제안된 여권 인식 방법을 실험한 결과, 제안된 방법이 여권 인식에 우수한 성능을 보였고 개선된 퍼지 ART 알고리즘이 기존의 퍼지 ART 알고리즘보다 클러스터 수가 적게 생성되고 인식률도 향상된 것을 확인하였다

  • PDF

Internal Pulsation (내면의 박동)

  • Choe, Gwang-Chun
    • Cartoon and Animation Studies
    • /
    • s.5
    • /
    • pp.517-524
    • /
    • 2001
  • 인간의 내면에 숨어있는 양면성을 주제로 그 양면의 극적인 대조를 이용하여 인간의 고뇌를 그리고, 타이포애니메이션을 이용하고 영상과 사운드의 접목을 통하여 인간내면의 갈등구조를 그리고자 했다. 겉으로는 일상적으로 반복되는 생활이 평화스럽게 보이지만, 인간의 내면에서는 항상 갈등이 존재함을 한 방울씩 떨어지는 반복적인 물방울 소리와 영상, 그리고 다듬이질 소리를 이용해 다들이질 치는 심장박동을 표현함으로써 대신하고자 했으며, 이와 더불어 극적인 타이포애니메이션을 구현하고자 했다. 인간내면의 갈등구조, 화면의 스크레치와 노이즈의 표현으로 이를 더욱 심화하고, 흑과 백, 그리고 맑은 영상과 비트있는 사운드를 통한 평화스러움과 인간내면 갈등구조에서 고뇌하면서도 평화스러워 보이는 한 인간의 속내를 표현하고자 했다. 인간내면의 갈등이 존재함에도 불구하고 평화스러워 보일 만큼 일상에 젖어 인간본연의 가치를 쉽게 잊고 살아갈 수도 있는 인간의 양면성, 급속한 변화를 담고 있는 현대사회 구조에 적응하여 살아가면서 느껴야 하는 무기력, 반복적인 생활, 획일화되는 사람들, 그러면서도 어쩔 수 없이 존재하는 내면의 갈등구조, 이 모든 것을 짧은 영상물에 담기에는 한계가 있으나, 어떤 결론을 만들어 제시하는 것이 아니라 상황의 표현에 중점을 두고 작품을 전개하려 했다.

  • PDF

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Development of an Infants' Sleep Health Program Using a Video for SIDS Prevention Education and Measurement of the Program's Effects (영아 수면건강 교육프로그램의 개발 및 효과)

  • Jang, Sook;Kim, Il-Ok
    • Child Health Nursing Research
    • /
    • v.21 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • Purpose: The purposes of this study were to develop an infant sleep health education program using a video for SIDS prevention education and to measure the effects of the program. Methods: The infant sleep health education program consisted of presentations and motor images. The formation of educational material was directed by the systematic design of instruction. Participants in this study were 59 primiparous women from postpartum care centers. The instruments used in this study were criterion referenced test items for knowledge about infant sleep health and confidence inventory. Experimental group I was given the treatment of infant sleep health education program. Experimental group II was given the program using a video reinforcement after 2 weeks. On the other hand, control group was given no treatment. Results: There was a significant increase in knowledge and confidence in the performance of mother's roles of both experimental group I and experimental group II over the control group. No significant difference was founds for knowledge and confidence in the performance of mother's roles between experimental group I and II. Conclusion: The results indicate that this program is a very effective intervention for better sleep health in infants by helping the mothers increase confidence in their role performance.

Acalculous Hemorrhagic Cholecystitis with Chronic Intraluminal Hematoma: MRI Findings (혈종을 동반한 무결석 출혈성 담낭염: 자기공명영상소견)

  • Oh, Sang-Young;Park, Mi-Hyun;Jee, Keum-Nahn;Jeon, Gyeong-Sik;Kim, Hong-Ja
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.195-198
    • /
    • 2009
  • Acalculous hemorrhagic cholecystitis is a rare complication of acute cholecystitis and is associated with a high mortality rate. We present a case of acalculous hemorrhagic cholecystitis with hematoma in the gallbladder lumen, which was diagnosed using magnetic resonance imaging (MRI). The T1- & T2-weighted MRI revealed gallbladder distension with a hypointense intraluminal hematoma. The excellent tissue contrast provided by MRI is useful for detecting hematomas in the cases of hemorrhagic cholecystitis.

  • PDF

Performance Evaluation of Image Saturation of Thermal Imaging Camera for the Fire Service (화재용 열화상 카메라의 영상포화특성 평가)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • Thermal imaging technology based on IR sensor with high transmittance through the fire smoke is considered as one of the advanced technology for the fire service. The present study has been performed to investigate the image saturation characteristics with thermal condition of target and background and evaluate the performance of image quality based on the contrast transfer function (CTF). For the present testing conditions, TIC using BST sensor did not show the image saturation and the image quality based on the CTF was proportional to the temperature difference between target and background. This study can be utilized as preliminary study to improve reliability and technical development of TIC.