A Study of the New Positioning Guide Based on the Correlation between the Orbit Meatus Line and Mandibular Body Angle in Paranasal Sinus Parietoacanthial Projection(Water's Method) (코곁굴 두정비극방향 검사 시 안와이공선과 아래턱뼈 몸통각도의 상관관계를 이용한 새로운 자세잡이 기준에 관한 연구)

  • Yong-Min Son;Han-Yong Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • 제18권4호
    • /
    • pp.335-344
    • /
    • 2024
  • In this study, we aim to investigate the correlation between the lateral images of Korean skulls and the angle between the OML and the Body of the Mandible. Additionally, we seek to provide criteria for the ease of positioning in clinical settings and establish standardized imaging procedures for the PNS Water's view examination. This study was conducted on a total of 202 patients who visited the radiology department of a general hospital and examined the skull lateral radiography. In addition to the patient images, skull phantoms were also utilized, and images were obtained using GC85A and EOS equipment. In this research, abbreviations related to the angle of the Body of Mandible were defined using PACS on lateral images. Measurements were taken for various angles, including ramus of mandible angle(RIA), accurate OML angle(TIA), OML and IR Angle(OIA), total mandibular length(TML), ramus height(RH), the angle between the pogonion, gonion, and condylion(MA). The validity of these measurements was confirmed using the skull phantom in the study. The age-specific average range for RIA was 22.67° to 26.04°, with measurements of 23.14° for males and 24.78° for females. The age-related mean ranges for TIA and OIA were 35.98° to 38.31° and 72.27° to 75.25°, respectively. For males, TIA was 36.74° and OIA was 72.73°, while for females, TIA was 36.43° and OIA was 73.38°. The age-dependent measurements for TML and RH ranged from 85.73 mm to 89.60 mm and 62.60 mm to 70.87 mm, respectively. Male values were 90.54 mm and 70.78 mm, while female values were 85.13 mm and 61.54 mm for TML and RH, respectively. The age-specific average range for MA was 55.95° to 58.63°, with measurements of 57.96° for males and 57.76° for females. Correlation analysis revealed a positive correlation between RIA and OIA, as well as between RIA and TIA. Based on the results of this study, which indicate a positive correlation between the angle of the Body of Mandible and the OML, it can be inferred that adjusting the mandible vertically to align with the imaging receptor may contribute to more accurate image acquisition during PNS Water's view examination. Therefore, it is believed that there is value in utilizing this relationship as a criterion for establishing new positioning standards, which could enhance the utility of a new positioning guide.

Small/Fast Moving Target Tracking base on Correlation Filter in Clutter Environment (클러터 환경에서 correlation filter기반 소형 고속 이동 표적 추적 시스템)

  • Jung, Young-Giu;Sun, Sun-Gu;Lee, Eui-Hyuk;Joo, Yong-Kwan;Kim, Taewan;Lee, Young-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제19권4호
    • /
    • pp.93-98
    • /
    • 2019
  • On today, optical system are the next generation weapon systems being studied in many countries, starting from USA. One of the most important technologies in optical system is a high-speed automatic target tracking system that can continuously track high-speed moving small targets. This paper designs an automatic target tracking system based on a correlated trekker that is robust against rapid shape changes for fast moving targets and small targets at a distance. The proposed system showed about 98% success rate in response to the targets that are under a complex background such as drone, ranger, etc.

Vibration Reduction Device for Directional Moving Satellite Antenna (지향성을 가지고 동작하는 위성 안테나 진동저감 장치 )

  • SeokWeon Choi;Sang-Soon Yong
    • Journal of Space Technology and Applications
    • /
    • 제2권3호
    • /
    • pp.187-194
    • /
    • 2022
  • Although the magnitude of the disturbance caused by the driving of the motor operated to secure the high-speed and precise directivity of the antenna is small, it acts as a major cause of impairing the image quality of the observation satellite, which requires precision directing performance. In order to acquire high-resolution image information through the improvement of the high-resolution observation satellite, proper vibration isolation and reduction design are required so that jitter generated when the directional antenna motor is driven is not transmitted to the main mission equipment. In this paper, the development process of the directional antenna vibration reduction device applied to real satellites and the effect of micro vibration reduction before and after application will be examined. This device was designed as a way to significantly improve the jitter problem by replacing only one gear in the directional antenna driving unit with a spring damper gear without any additional interface equipment. It was first applied and launched to a high-resolution earth observation satellite, and has been successfully operated so far.

VDT작업대 설계의 인간공학적 연구

  • 권영국;이성렬;민재형
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 대한산업공학회/한국경영과학회 1992년도 춘계공동학술대회 발표논문 및 초록집; 울산대학교, 울산; 01월 02일 May 1992
    • /
    • pp.581-591
    • /
    • 1992
  • 최근 급속한 사무자동화와 함께 컴퓨터의 사용이 보편화되어 가지고 있다. 이에 따라 컴퓨터등 VDT에 매달려 일하는 사무직 근로자들이 시력장해, 두통, 어깨결림, 요통, 스트레스성 장애등 새로운 질병에 시달리고 있다. 이것은 "VDT증후군"(Visual Display Terminal Syndrome) 또는 "VDT병"이란 신종 직업병이다. 컴퓨터 수상기 화면을 계속해서 들여다보면 화면에서 나오는 자외선과 강한 빛으로 눈에 무리가 와 충혈되고 침침해지며 두통 증세가 나타난다. 이런 초기증상이 6개월이상 계속되면 시력이 떨어지고 만성피로를 느끼는가 하면, 때때로 독감과 비슷한 증상이 나타나며, 심하면 탈모현상까지 경험하게 된다. 요즘 시행되고 있는 초등 고교 컴퓨터교육의 의무화와 2천년대의 1가구 1단말기 설치를 목표로한 컴퓨터 영상단말기의 급속한 보급으로, 앞으로는 사무실뿐만 아니라 일반 가정에까지 컴퓨터 이용이 일상화될 전망이고 보면 VDT작업에 따른 건강장해 문제는 더이상 가볍게 볼 수 없는 문제이다. 이에 대해 선진국에서는 작업시간 규제, 회사가 종업원의 정기적인 시력검진 및 시력교정에 필요한 비용을 보조하도록 하는가하면 실작업환경 개선등 다각적인 대책을 마련하고 있다. 미국, 유럽, 일본등 선진국에서는 VDT작업 여성들의 유산 및 기형아 출산등 임신이상에 관한 실태보고서까지 나오고 있어 여성들에게 커다란 충격을 던져주고 있다. 그러나 우리나라에서는 VDT병 증상을 호소하는 근로자들의 직업병예방 및 대책에 큰 어려움을 겪고있다. 그러므로, VDT작업으로 인한 건강상의 문제, 작업환경 및 작업자세등을 조사하여 문제점과 예방대책을 살펴보고, 작업장을 인간공학적으로 설계하고 평가하여 사용자의 건강을 보호하고 생산성의 향상에 도움이 되고자 한다.생산성의 향상에 도움이 되고자 한다.Action Code를 계산처리부로 넘겨준다. 입력처리부에서는 Mouse와 Keyboard 어느것으로나 입력이 가능하도록 해준다. 출력처리부에서는 Action Code에 따라 계산처리부에서 계산된 결과를 화면에 보여주기 위한 각종 2D/3D Graphic Routine들이 포함되어있어 계산처리부에서 불러쓰도록 되어있다.에서는 전문가시스템 기법을 도입해서 사출금형 공정계획전문가의 지식과 경험을 획득하여 지식베이스를 구축하고, 전문가시스템 셀(shell)중 CLIPS를 이용하여 자동공정계획시스템인 Mold CAPP을 개발하였다.PP을 개발하였다.며 이와 상이한 결과도 보여주고 있다. 이상으로 볼 때 1) 가정하수의 질을 높이기 위하여 분뇨정화조 의 효율증대 2) 산업폐수의 공정별 폐수량의 조절 및 폐수성 상에 따른 총량규제에 대비한 효율증대 3) 하천의 오염부하와 자정능력 최대한 부여 4) 폐수처리를 위한 미생물제개발 및 오염지표 종 연구와 오염내성 생물의 연구등이 종합적 으로 수행되어야 한다. 5) 이상의 모든 조사와 연구결과를 객관적으로 표기할 수 있도록 하천의 이정표가 정해져야 하겠다.7%)에 비해 유의하게 낮았고 정상군과는 유의한 차이를 보이지 않았다.상고나성이 있었다. 혈중 호모시스테인 농도는 질병의 위험요인으로서 뿐 아니라 대사적으로 밀접하게 연관된 비타민 영양상태의 biomarker로서도 그 영향력이 크다고 할 수 있다. 따라서 성별에 다른 다양한 연령집단에서 건강한 일반인과 심혈관계 질환자 등을 대상으로 호모시스테인과 비타민 영양상태에 대한 연구가 체계적으로 이루어 져야 할 것이다.태를 보다 효율적으로 증진시킬 수 있는 대안이 마련되어져야 한다고 사료된다.$\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도

  • PDF

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제14권1호
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • 제14권7호
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Estimation of Bridge Vehicle Loading using CCTV images and Deep Learning (CCTV 영상과 딥러닝을 이용한 교량통행 차량하중 추정)

  • Suk-Kyoung Bae;Wooyoung Jeong;Soohyun Choi;Byunghyun Kim;Soojin Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제28권3호
    • /
    • pp.10-18
    • /
    • 2024
  • Vehicle loading is one of the main causes of bridge deterioration. Although WiM (Weigh in Motion) can be used to measure vehicle loading on a bridge, it has disadvantage of high installation and maintenance cost due to its contactness. In this study, a non-contact method is proposed to estimate the vehicle loading history of bridges using deep learning and CCTV images. The proposed method recognizes the vehicle type using an object detection deep learning model and estimates the vehicle loading based on the load-based vehicle type classification table developed using the weights of empty vehicles of major domestic vehicle models. Faster R-CNN, an object detection deep learning model, was trained using vehicle images classified by the classification table. The performance of the model is verified using images of CCTVs on actual bridges. Finally, the vehicle loading history of an actual bridge was obtained for a specific time by continuously estimating the vehicle loadings on the bridge using the proposed method.

Comparison of Heart Rate Variability(HRV) in Pregnant Woman and Non-pregnant Woman (임신 여성과 가임기 여성의 심박변이도(HRV) 비교)

  • Kim, Su-min;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • 제15권4호
    • /
    • pp.499-505
    • /
    • 2021
  • In this study, HRV signals are analyzed to compare the autonomic nervous system activity of non-pregnant women and pregnant women. 99 disease-free pregnant women and 27 non-pregnant women from W Hospital participated in the study. The acquired HRV signals were used by the program to perform time domain analysis and frequency domain analysis. The measured values were statistically analyzed for differences between pregnancy periods through a one-way ANOVA. In the results, SDNN and RMSSD in time domain analysis had significantly higher results in early pregnancy and non-pregnant women compared to mid- and late pregnancy. In frequency domain analysis, LF and HF had significantly higher values for pregnancy and non-pregnancy compared to midand late-term, but there was no significant difference between VLF and LF/HF. his means that as pregnancy progresses, the ability to control autonomous nerves decreases in the middle and late stages of pregnancy and increases physical fatigue and mental fatigue. Therefore, the longer the pregnancy period, the more special care is needed to maintain mental and physical stability of pregnant women.

Application of Spectral Indices to Drone-based Multispectral Remote Sensing for Algal Bloom Monitoring in the River (하천 녹조 모니터링을 위한 드론 다중분광영상의 분광지수 적용성 평가)

  • Choe, Eunyoung;Jung, Kyung Mi;Yoon, Jong-Su;Jang, Jong Hee;Kim, Mi-Jung;Lee, Ho Joong
    • Korean Journal of Remote Sensing
    • /
    • 제37권3호
    • /
    • pp.419-430
    • /
    • 2021
  • Remote sensing techniques using drone-based multispectral image were studied for fast and two-dimensional monitoring of algal blooms in the river. Drone is anticipated to be useful for algal bloom monitoring because of easy access to the field, high spatial resolution, and lowering atmospheric light scattering. In addition, application of multispectral sensors could make image processing and analysis procedures simple, fast, and standardized. Spectral indices derived from the active spectrum of photosynthetic pigments in terrestrial plants and phytoplankton were tested for estimating chlorophyll-a concentrations (Chl-a conc.) from drone-based multispectral image. Spectral indices containing the red-edge band showed high relationships with Chl-a conc. and especially, 3-band model (3BM) and normalized difference chlorophyll index (NDCI) were performed well (R2=0.86, RMSE=7.5). NDCI uses just two spectral bands, red and red-edge, and provides normalized values, so that data processing becomes simple and rapid. The 3BM which was tuned for accurate prediction of Chl-a conc. in productive water bodies adopts originally two spectral bands in the red-edge range, 720 and 760 nm, but here, the near-infrared band replaced the longer red-edge band because the multispectral sensor in this study had only one shorter red-edge band. This index is expected to predict more accurately Chl-a conc. using the sensor specialized with the red-edge range.

The Effect of Dose Distribution under Treatment Techniques on Cerebrospinal Irradiation (뇌 및 척수조사시 치료기법의 변화가 선량분포에 미치는 영향)

  • Lee, Seungchul;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • 제10권1호
    • /
    • pp.21-28
    • /
    • 2016
  • This study tries to evaluate the usefulness CSI treatment. Compare the standard technique and simple technique, using the volume region of a high dose of Field joints (hot spot) or low dose regions (cold Spot). In patients who agreed to this study, obtain CT image using CT simulator skull to pelvis region. Standard Technique were performed on the movement of the joint radiation field range and simple technique has set a treatment plan to secure the radiation field range and analyzed treatment planning. Under analysis standard technique occurred the area of the high dose(Hot Spot) for the area overlapping the field and simple technique showing a uniform doses. CI indices of standard technique and simple technique was 1.6~3, 1.6~1.87, CN indices was 0.32~0.53, 0.46~0.51 and HI indices was 0.11~0.33, 0.2~0.26. Therefore, adjacent to part of the dose distribution junction more equally than simple technique compared to the Standard Technique. Compare the dose distribution patterns using CI, CN, HI indices, showed a uniform dose distribution in the simple technique. so, simple technique was determined appropriate treatment the CSI.