Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • 제29권1호
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • 제39권1호
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제19권2호
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Dose Reduction Method for Chest CT using a Combination of Examination Condition Control and Iterative Reconstruction (검사 조건 제어와 반복 재구성의 조합을 이용한 흉부 CT의 선량 저감화 방안)

  • Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제17권7호
    • /
    • pp.1025-1031
    • /
    • 2023
  • We aimed to evaluate the radiation dose and image quality by changing the Scout view voltage in low-dose chest CT (LDCT) and applying scan parameters such as AEC (auto exposure control) and ASIR (adaptive statistical iterative reconstruction) to find the optimal protocol. Scout view voltage was varied at 80, 100, 120, 140 kV and after measuring the dose 5 times using the existing low-dose chest CT protocol, the appropriate kV was selected for the study using the Dose report provided by the equipment. After taking a basic LDCT shot at 120 kV, 30 mAs, ASIR 50% was applied to this condition. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed by measuring Background noise (B/N). For dose comparison, CTDIvol and DLP provided by the equipment were compared and analyzed using the formulas. The results indicated that the protocol of scout 140 + LDCT + ASIR 50 + AEC reduced radiation exposure and improved image quality compared to traditional LDCT, providing an optimal protocol. As demonstrated in the experiment, LDCT screenings for asymptomatic normal individuals are crucial, as they involve concerns over excessive radiation exposure per examination. Therefore, applying appropriate parameters is important, and it is expected to contribute positively to the public health in future LDCT based health screenings.

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance (이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발)

  • Ki-Yeol Eom;Byeong-Seok Min
    • Journal of Internet Computing and Services
    • /
    • 제25권1호
    • /
    • pp.99-107
    • /
    • 2024
  • Along with economic growth and industrial development, there is an increasing demand for various electronic components and device production of semiconductor, SMT component, and electrical battery products. However, these products may contain foreign substances coming from manufacturing process such as iron, aluminum, plastic and so on, which could lead to serious problems or malfunctioning of the product, and fire on the electric vehicle. To solve these problems, it is necessary to determine whether there are foreign materials inside the product, and may tests have been done by means of non-destructive testing methodology such as ultrasound ot X-ray. Nevertheless, there are technical challenges and limitation in acquiring X-ray images and determining the presence of foreign materials. In particular Small-sized or low-density foreign materials may not be visible even when X-ray equipment is used, and noise can also make it difficult to detect foreign objects. Moreover, in order to meet the manufacturing speed requirement, the x-ray acquisition time should be reduced, which can result in the very low signal- to-noise ratio(SNR) lowering the foreign material detection accuracy. Therefore, in this paper, we propose a five-step approach to overcome the limitations of low resolution, which make it challenging to detect foreign substances. Firstly, global contrast of X-ray images are increased through histogram stretching methodology. Second, to strengthen the high frequency signal and local contrast, we applied local contrast enhancement technique. Third, to improve the edge clearness, Unsharp masking is applied to enhance edges, making objects more visible. Forth, the super-resolution method of the Residual Dense Block (RDB) is used for noise reduction and image enhancement. Last, the Yolov5 algorithm is employed to train and detect foreign objects after learning. Using the proposed method in this study, experimental results show an improvement of more than 10% in performance metrics such as precision compared to low-density images.

Comparison of Blinking Patterns When Watching Ultra-high Definition Television: Normal versus Dry Eyes (초고선명 텔레비전 시청 시 정상안과 건성안에서의 눈깜박임 양상 비교)

  • Kang, Byeong Soo;Seo, Min Won;Yang, Hee Kyung;Seo, Jong Mo;Lee, Sanghoon;Hwang, Jeong-Min
    • Journal of The Korean Ophthalmological Society
    • /
    • 제58권6호
    • /
    • pp.706-711
    • /
    • 2017
  • Purpose: To analyze blinking patterns when watching an ultra-high definition (UHD) television and to compare the results between normal eyes and dry eyes. Methods: A total of 59 participants aged from 13 to 69 years were instructed to watch a colorful and dynamic video on a UHD television for 10 minutes. Before and after watching the UHD television, we measured the best corrected visual acuities, autorefraction, tear-break-up-time, degree of corneal erosion and conjunctival hyperemia via slit lamp biomicroscopy. In addition, questionnaires for the evaluation of eye fatigue and symptoms of a dry eye were completed. The definition of dry eye syndrome was that the tear-break-up-time of one of the eyes was less than 5 seconds, conjunctival injection, or marked corneal erosion. The number of blinks and the duration of blinking were both measured and analyzed at the early and late phases of video-watching. Results: After watching the UHD television in the normal eye group, the tear-break-up-time was significantly decreased (p < 0.001) and the degree of corneal erosion was significantly increased (p = 0.023). However, the subjective symptoms of participants were not aggravated (p = 0.080). There were no significant differences in blinking patterns in the dry eye group. On the other hand, in the normal eye group, the mean blinking time was significantly increased (p = 0.030). Conclusions: Watching an UHD television changes the tear-break-up-time, degree of corneal erosion, and blinking pattern in normal eyes, which may increase the risk of dry eye syndrome.

Template-Based Object-Order Volume Rendering with Perspective Projection (원형기반 객체순서의 원근 투영 볼륨 렌더링)

  • Koo, Yun-Mo;Lee, Cheol-Hi;Shin, Yeong-Gil
    • Journal of KIISE:Computer Systems and Theory
    • /
    • 제27권7호
    • /
    • pp.619-628
    • /
    • 2000
  • Abstract Perspective views provide a powerful depth cue and thus aid the interpretation of complicated images. The main drawback of current perspective volume rendering is the long execution time. In this paper, we present an efficient perspective volume rendering algorithm based on coherency between rays. Two sets of templates are built for the rays cast from horizontal and vertical scanlines in the intermediate image which is parallel to one of volume faces. Each sample along a ray is calculated by interpolating neighboring voxels with the pre-computed weights in the templates. We also solve the problem of uneven sampling rate due to perspective ray divergence by building more templates for the regions far away from a viewpoint. Since our algorithm operates in object-order, it can avoid redundant access to each voxel and exploit spatial data coherency by using run-length encoded volume. Experimental results show that the use of templates and the object-order processing with run-length encoded volume provide speedups, compared to the other approaches. Additionally, the image quality of our algorithm improves by solving uneven sampling rate due to perspective ray di vergence.

  • PDF

A study of contrast agent peak time using biomechanics factors experimental contrast medium infusion test using at contrast enhanced magnetic resonance angiography (조영증강검사 시 생체 요인을 이용한 조영제 peak time에 관한 연구)

  • Son, Soon-Yong;Kim, Yoon-Shin;Choi, Kwan-Woo;Seo, Sung-Mi;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권2호
    • /
    • pp.786-792
    • /
    • 2013
  • In this study was explored minimize side effects due to the additional injection of contrast medium and maintaining a high resolution imaging applied to the inspection and analysis of the contrast medium that affect the peak time biomechanics factors. Included 48 patients using the test bolus method, after measuring a patient's biomechanics factors of inspection before and during the test, correlation between contrast medium peak time and learn, matches the regression equation calculated and measured contrast medium peak time was assessed by the Bland Altman plot. Research result, inspections of SBP, HR contrast medium peak time and a significant negative correlation was, step 1, every increase, the contrast medium peak time significantly to -0.018 and -0.159 decreased, a fairly high concordance no difference between the two method. In conclusion, the regression equation using the existing methods, while maintaining excellent image quality that contrast medium is reduced to a patient, it can conclude that the alternative to the existing methods.