• Title/Summary/Keyword: 영상의학부

Search Result 234, Processing Time 0.027 seconds

Incidentally Diagnosed Duodenal Web in Infancy (영아기에 우연히 진단된 십이지장 격막)

  • Suh Young Kim;Byoung Hee Han;Ki Young Park;Jung-Man Namgoong;Da Hee Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.724-729
    • /
    • 2022
  • A duodenal web is an incomplete diaphragm of the duodenal lumen that causes a partial or (intermittent) complete obstruction. The size of a duodenal web's aperture determines the degree of obstruction, age at presentation, and radiologic findings. We report a case of duodenal web incidentally diagnosed in a 14-month-old boy who presented to the hospital after ingesting a foreign body. We provide a comprehensive report of multiple studies through abdominal radiograph, upper gastrointestinal study, endoscopy, and surgical findings. We emphasize that the duodenum should be considered as the location of the obstruction when infants exhibit delayed discharge or dynamic positioning of a foreign body in a radiologic examination.

Granular Cell Tumor of the Axillary Accessory Breast: A Case Report (액와부 부유방에 발생한 과립 세포 종양: 증례 보고)

  • Youn Joo Jung;Kyung Jin Nam;Ki Seok Choo;Kyeyoung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.275-279
    • /
    • 2023
  • Granular cell tumors (GCTs) are rare benign soft tissue tumors that can occur throughout the body, particularly the head and neck; only 5%-8% of GCTs occur in the breast. We report a case of a GCT of the axillary accessory breast, which is a rare location of this tumor. A 50-year-old woman had a 2-month history of a palpable mass in the left axilla. Physical examination, as well as mammographic and ultrasonographic findings suggested a breast malignancy. Histopathological examination showed a benign GCT, and wide local excision was performed. The patient has remained disease-free over 2 years postoperatively. Although most GCTs are benign, wide complete resection of the tumor and follow-up are required considering the possibility of recurrence. The radiologist should know the characteristics of GCTs as a differential diagnosis of breast and axillary lesions to prevent unnecessary treatment.

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

Comparison of Stress-rest and Rest-stress One Day Myocardial Perfusion Scintigraphies in Detecting Coronary Artery Diseases (부하-휴식과 휴식-부하 1일 심근관류영상법의 관동맥질환 진단율 비교)

  • Bom, Hee-Seung;Min, Jung-Jun;Song, Ho-Cheon;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 1997
  • It has been shown that both rest and stress myocardial perfusion imagings with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age $57{\pm}9$ years) and 120 patients (79 males, 41 females, mean age $59{\pm}10$ years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ${\geq} 50%$. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using $^{99m}Tc$ agents were comparable and were very sensitive tests in detecting coronary artery diseases.

  • PDF

Persistent Primitive Olfactory Artery Type 4 with Fusiform Aneurysm: A Case Report (방추형동맥류를 동반한 제4형 잔류 원시 후각동맥의 영상 소견: 증례 보고)

  • Heecheol Park;Jin Wook Baek;Hae Woong Jeong;Young Jin Heo;Suyoung Yun;Ji-Yeon Han
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1361-1366
    • /
    • 2023
  • The persistent primitive olfactory artery (PPOA) is a rare variant of the anterior cerebral artery, first reported in 1979. It reportedly has a high correlation with the development of aneurysms, owing to the hemodynamic stress induced by the structural characteristics of the hairpin turn. Herein, we present a rare case of PPOA type 4 with a fusiform aneurysm at the hairpin turn segment in a 46-year-old female with occasional headaches. Time-of-flight MR angiography and transfemoral cerebral angiography revealed an unusual branch arising from the left A1 segment, running anteromedially along the ipsilateral olfactory tract, and turning the hairpin posterior to the olfactory bulb. This branch continued into the left accessory middle cerebral artery, and a fusiform aneurysm was observed at the hairpin segment. No further treatment was performed, and follow-up imaging was recommended. Nevertheless, it is essential to recognize and diagnose these rare variations.

Variability of Transrectal Shear Wave Elastography in a Phantom Model (팬텀연구에서 경직장 전단파탄성초음파의 가변성)

  • Jihyun Lee;Seong Kuk Yoon;Jin Han Cho;Hee Jin Kwon;Dong Won Kim;Jun Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1110-1122
    • /
    • 2023
  • Purpose This study aimed to assess the variability of transrectal shear wave elastography (SWE) using a designed phantom. Materials and Methods In a phantom, the SWE values were examined by two radiologists using agarose and emulsion silicone of different sizes (1, 2, and 3 cm) and shapes (round, cubic) at three depths (1, 2, and 3 cm), two region of interest (ROI) and locations (central, peripheral) using two ultrasound machines (A, B from different vendors). Variability was evaluated using the coefficient of variation (CV). Results The CVs decreased with increasing phantom size. Significant changes in SWE values included; agarose phantom at 3 cm depth (p < 0.001; machine A), 1 cm depth (p = 0.01; machine B), emulsion silicone at 2 cm depth (p = 0.047, p = 0.020; both machines). The CVs increased with increasing depth. Significant changes in SWE values included; 1 cm agarose (p = 0.037, p = 0.021; both machines) and 2 cm agarose phantom (p = 0.047; machine A). Significant differences in SWE values were observed between the shapes for emulsion silicone phantom (p = 0.032; machines A) and between ROI locations on machine B (p ≤ 0.001). The SWE values differed significantly between the two machines (p < 0.05). The intra-/inter-operator agreements were excellent (intraclass correlation coefficient > 0.9). Conclusion The phantom size, depth, and different machines affected the variability of transrectal SWE.

A New Healthcare Policy in Korea Part 1: Expanded Reimbursement Coverage of Brain MRI, Brain/Neck MRA, and Head and Neck MRI by National Health Insurance (새로운 건강보험 보장성 강화 대책 1부: 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여 확대)

  • Eunhee Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1053-1068
    • /
    • 2020
  • In accordance with the new healthcare policy of government (Moon Jae-In Care) to strengthen health insurance coverage, the National Health Insurance (NHI) coverage of brain magnetic resonance imaging (MRI), brain/neck MR angiography (MRA), and head and neck MRI have been expanded since 2018 in Korea. This article has been reviewed focusing on the "Detailed matter concerning criteria and method for providing reimbursed services in the NHI. Some revisions" regarding reimbursement for MRI, which was revised from October 2018 to April 2020 and is currently in effect. It included the MRI reimbursement system in Korea, recent adjustment of the reimbursement coverage for patients with headache or dizziness, and reimbursement coverage, standard imaging, and radiologic report of brain MRI, brain/neck MRA and head and neck MRI. This article could help radiologists gain knowledge on health insurance to protect the expertise of the radiologist and to play a leading role in the hospital. As the policy changes, detailed matter concerning criteria and method for providing reimbursed services in the NHI may be revised. Therefore, radiologists should update issues related to insurance reimbursement for MRI continuously.

Transcholecystic Duodenal Drainage as an Alternative Decompression Method for Afferent Loop Syndrome: Two Case Reports (들장관증후군의 대체 감압 치료로서 경담낭 십이지장 배액술: 두 건의 증례 보고)

  • Jihoon Hong;Gab Chul Kim;Jung Guen Cha;Jongmin Park;Byunggeon Park;Seo Young Park;Sang Un Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.661-667
    • /
    • 2024
  • Afferent loop syndrome (ALS) is a rare complication of gastrectomies and gastrointestinal reconstruction. This can predispose patients to fatal conditions, such as cholangitis, pancreatitis, and duodenal perforation with peritonitis. Therefore, emergency decompression is necessary to prevent these complications. Herein, we report two cases in which transcholecystic duodenal drainage, an alternative decompression treatment, was performed in ALS patients without bile duct dilatation. Two patients who underwent distal gastrectomy with Billroth II anastomosis sought consultation in an emergency department for epigastric pain and vomiting. On CT, ALS with acute pancreatitis was diagnosed. However, biliary access could not be achieved because of the absence of bile duct dilatation. To overcome this problem, a duodenal drainage catheter was placed to decompress the afferent loop after traversing the cystic duct via a transcholecystic approach. The patients were discharged without additional surgical treatment 2 weeks and 1 month after drainage.

특수의료장비의 설치 및 운영에 관한 규칙에 의한 정도관리 시행

  • 정해조;김희중;김기황
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.51-51
    • /
    • 2003
  • 국민건강보험재정건전화특별법 (제정 2002.1.19 법률 제 6620호)은 건강보험의 재정적자를 조기에 해소하고 재정수지의 균형을 이루도록 함으로써 건강보험제도의 발전과 국민건강 증진 도모를 그 목적으로 하며, 제14조(특수의료장비의 설치ㆍ운영)에서 의료기관은 보건복지부장관이 고시한 특수의료장비를 설치ㆍ운영하고자 하는 때에는 보건복지부령이 정하는 바에 따라 이를 등록하여야 하며 설치 인정 기준에 적합하게 설치ㆍ운영하여야 하고 정기적인 품질관리를 받아야한다고 명시하였다. 특수 의료장비의 설치 및 운영에 관한 규칙 (제정 2003.1.14 보건복지부령 제235호)은 국민건강보험재정건전화특별법이 제정됨에 따라 특수의료장비의 적정 한 설치와 활용을 위하여 의료기관에서 설치ㆍ운영하는 특수의료장비의 등록절차 설치인정기준 및 품질관리 절차 등을 정하고 특수의료장비에 대한 관리체계를 확립하려는 것이다. 특수의료장비의 설치 및 운영에 관한 규칙의 주요 골자는 가. 의료기관에서 특수장비를 설치ㆍ운영하고자 하는 경우 보건복지부장관 또는 시ㆍ도 지사에게 등록하도록 하였는바, 이 등록에 대한 절차와 특수의료장비의 설치인정기준을 정함, 나. 특수의료 장비에 대한 정기적인 품질관리검사를 서류검사와 정밀감사로 구분하여 서류검사는 1 년마다, 정밀검사는 3 년마다 받도록 함, 다. 품질관리검사기관의 장은 특수의료장비품질관리검사성적서를 신청인에게 교부하고, 보건복지부 또는 시ㆍ도지사 및 건강보험심사평가위원장에게 검사결과를 통보하도록 함, 라. 특수의료정비를 설치ㆍ운영하는 의료기관의 개설자 또는 관리자 및 품질관리검사기관의 장이 작성ㆍ비치ㆍ보존하여야할 서류를 정함이다. 보건복지부장관에게 등록하여야할 특수의료장비는 자기공명영상촬영장치와 전산화단층촬영 장치이며, 시ㆍ도지사에게 등록하여야할 특수의료장비는 유방촬영용장치이다. 본 발표에서는 특수의료장비의 설치 및 운영에 관한 규칙에 대한 개요와 연세의료원 세브란스병원에서 시행하고 있는 특수의료장비의 정도관리 검사, 팬텀영상검사, 그리고 임상영상검사를 소개하고자한다.

  • PDF

Effect of Stitching Range on Radiation Dose to Eyeball, Thyroid, Breast, Pelvis in Whole Spine Radiography with Standing Position (선 자세 척추 전장 방사선검사 시 스티칭 범위가 장기(수정체, 갑상샘, 유방, 골반부)의 선량에 미치는 영향)

  • Min-Ji, Hong;Han-Yong, Kim;Dong-Hwan, Kim;Young-Cheol, Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.47-52
    • /
    • 2023
  • In whole spine radiography using the stitching technique, overlapping parts occur in the process of synthesizing the three segmented images, so some anatomical structures may be repeatedly exposed, and it has been thought that the dose increases as the scan range increases. However, in the whole spine radiography using the stitching technique in this study, under the condition that the stitching range is taken in the same three splits, the overlapping area decreases as the stitching range increases, so in the case of breasts included in the overlapping range, the dose value decreased by almost half as the stitching range increased from 90 cm to 105 cm. During spinal full-length radiological examination using the stitching method, an appropriately long stitching range could be set to reduce the exposure dose of the breast.