• Title/Summary/Keyword: 염분도 측정

Search Result 266, Processing Time 0.033 seconds

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

A Study on Environmental Characteristic of Insulators for Ultra High Voltage Using ESDD and NSDD Measurement (초고압애자의 ESDD 및 NSDD 측정을 통한 내환경 특성 연구)

  • Lee, Sang-Yun;Lim, Yun-Seog;Lee, Won-Kyo;Lee, Dong-Il;Shin, Koo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2095_2096
    • /
    • 2009
  • 송배전용 설비에 사용되는 애자의 신뢰성은 전기적인 절연성질과 기계적인 내구성 뿐만 아니라 애자가 설치된 송전선로의 오손에 의한 내환경성에 의해서도 결정될 수 있다. 지금까지 염분 및 분진이 심한 지역에서 오손물이 애자에 미치는 영향에 대한 연구는 전기적, 기계적 신뢰성에 영향을 미치는 오손물질의 성분 분석 등을 통해 저압과 고압의 환경에서 진행되어 왔다.[1] 본 논문에서는 2003년부터 우리나라에서 운전해 오고 있는 765kV 애자오손 신뢰성 검토와 미국 전력연구원(EPRI)에서 수탁받은 765kV 고분자애자 특성연구의 일환으로, 765kV 상용선로에 사용되는 애자류에 대한 장기열화특성을 연구하기 위해 765kV 실증 시험설비를 구축하였다. 아울러, 765kV 애자 장기열화특성 분석을 위한 기초연구로 염분 및 분진 오손도를 측정하여 765kV 환경에서 애자종류에 따른 오손 특성을 검토하였다. 그 결과, RTV 실리콘고무 코팅 애자가 자기 및 유리재 애자에 비해 염분 오손도 면에서 비교적 우수한 특성을 지님을 확인 할 수 있었다.

  • PDF

Effect of Salinity Concentration on Aerobic Composting of Food Waste (염분함량이 음식물쓰레기의 호기성 퇴비화에 미치는 영향)

  • Kim, Nam-Chan;Kim, Do-Hee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.124-129
    • /
    • 2000
  • The purpose of this study is to estimate the degradation rate and process efficiency of the composting according to the salinity concentration. The samples of food waste for this study were collected in Pocheon-Gun, Kyungki-Do. The collected samples were adjusted to the optimum range of moisture content, pH and C/N ratio. After that, adding the saline, the samples with 3 different salinity concentrations(1%, 5% and 10%) were made. Then each sample was fed into the reactor with temperature controller. During the aerobic composting process, the change of the physical and chemical properties of the sample as temperature, pH, C/N ratio and $CO_2$ and $O_2$ concentration in the reactor were measured. From the experiment of this study, the result are following. The highest temperatures are $59^{\circ}C$ at RUN 1(1% salinity conc.), $49^{\circ}C$ at RUN 2(5% salinity conc.) and $45^{\circ}C$ at RUN 3(10% salinity conc.). The change of $CO_2$ production and $O_2$ consumption have the positive correlation with the change of the temperature. $CO_2$ production and $O_2$ consumption are peaked at the low salinity concentration. During composting, Run 1, RUN 2 and RUN 3 are increased pH to 8.9, 8.6 and 7.2 and slowly decreased C/N ratio to 18.9, 19.1 and 22.1 and moisture content to 51.1%, 53.7% and 55.0%, respectively. It is supposed that increasing salinity concentration causes the retarding of the microbial degradation activities during the composting. And for the efficient composting, the salinity concentration in the sample hat to be maintained below 5%.

  • PDF

부유식 건축물 유지관리를 위한 환경부하 정량화 기법에 관한 연구

  • Jo, Gyu-Hwan;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.10a
    • /
    • pp.285-287
    • /
    • 2012
  • 염해는 철근 콘크리트 구조물의 주요 열화원인으로서 특히 수해양 부유식 건축물의 상부구조는 비래염분에 의한 피해에 노출되어 있고, 해수에 접하고 있는 함체는 다공질 콘크리트의 모세관으로 염수이온이 침투하므로 상당히 높은 수위의 열화 환경에 노출되어 있다고 분류할 수 있다. 본 연구는 해양에서 유입되는 비래염분량을 정량화하여 철근 콘크리트 구조물 뿐만아니라 강재 건자재의 장수명화를 꾀하는 기초자료를 구축하고자 하였다. 1년간에 걸쳐 측정된 비래염분유입 지역은 기존연구에서 조사된 1km 범위을 상당히 초과하고 있으며 그 량도 강재 발청농도를 탁월하게 상회하는 것으로 분석되었다.

  • PDF

Development of Multidirection Incoming Salt Collector that Excludes Backward Wind (후풍의 영향을 배제한 다방향 비래염분 포집기 개발과 비래염분 포집에 관한 연구)

  • Park, Dong-Cheon;Ahn, Jae-Cheol;Kim, Woo-Jae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.627-633
    • /
    • 2011
  • Evaluation of the amount of chloride ion coming from the sea is very important in assessing the life expectancy of Reinforced Concrete structures. Developed in Japan, the incoming salt collector has been used to this day. Unfortunately, the incoming salt collector has had a bad reputation, which is caused by backward wind. Backward wind causes a reduction of the amount of salt collected in collector's gauze. The collector was developed to eliminate the effect of backward wind. Simulation test in the laboratory and site measurement were performed to determine the amount of incoming salt according to the height. The performance was verified through analytic and experimental methods.

A Study on the Telemetry system for the Inhabitant Environments and Distribution of Fish-I - Sea Temperature , Salinity and Distribution of Fish - (어류의 서식환경과 분포생태의 원격계측에 관한 연구-I - 수온, 염분과 어류의 분포생태 -)

  • Sin, Hyeong-Il;An, Yeong-Hwa;Sin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.321-333
    • /
    • 1997
  • This paper describe on the transmitting/receiving functions and the monitoring effects for the telemetry system which is designed to monitor the environmental condition of a culturing fishery ground inside a bay. The telemetry experiments were carried out by the telemetry system which constructed with the sea water temperature/salinity measuring sensor and telesounder at culturing fishery ground located in the coast of Sangyang-Myon, Kyongsangnam-Do province from October, 1995 to May, 1996. The results of this experiment showed that the developed telemetry system could be used for monitoring the sea water temperature/salinity and the distribution of fish in culturing fishery ground.

  • PDF

Biomass and Species Composition of Phytoplankton and Zooplankton along the Salinity Gradients in the Seomjin River Estuary (섬진강 하구역에서 염분경사에 따른 동${\cdot}$식물플랑크톤의 현존량 및 종조성)

  • Lee, Pyung-Gang;Park, Chul;Moon, Chang-Ho;Park, Mi-Ok;Gwon, Kee-Young
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.2
    • /
    • pp.93-102
    • /
    • 2001
  • Biomass and species composition of phytoplankton and zooplankton along the salinity gradients in the Seomjin River estuary were investigated in March, July, September and November, 1999. The locations of sampling sites were set based on the surface salinity during each cruise rather than geographic locations. A total of 96 phytoplankton species were identified with 60 diatom species in the study area. The species number of green algae was relatively high in low salinity region while the number of dinoflagellates increased in high salinity areas. Monthly mean of phytoplankton biomass ranged from 183 cells/ml to 833 cells/ml. There was a diatom bloom of Skeletonema costatum in November at the 5-15 psu salinity region and sharp decrease of biomass in very low salinity region occurred in March. During the rainy season in July with the salinity less than 8.1 psu, the green algae dominated in most of the study areas. Chroomonas spp. were highly dominant in March and September and the biomass increased towards the high salinity regions. A total of 83 zooplankton taxa were identified with 72 marine and 11 freshwater taxa. Major group of marine form was copepods with34 taxonomic groups. Most freshwater taxa were aquatic insects. Threshold salinities of freshwater zooplankton appearance were 8.1 psu in July, 4.7 psu in September, and 0.2 psu in November. The number of taxa appeared and abundances of zooplanktons were minimal in the middle of salinity gradients in this estuary.

  • PDF

Exploration of Submarine Spring Along the Coastal Areas of Busan Metropolitan City (부산 인근 연안해역에서 해저 용천수 유출 탐사)

  • Lee, Yong-Woo;Khim, Boo-Keun;Kim, Sunghan
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.4
    • /
    • pp.178-185
    • /
    • 2013
  • We measured salinity and $^{222}Rn$ concentration to explore submarine spring along the coastal areas (Mundongri, Icheon-ri, Jukseong-ri, Daebyeon-ri, Yeonhwa-ri, and Dadae-po) including Ilkwang Bay of Busan Metropolitan City in 2009 and 2010. Before field observation, we selected the potential and possible locations of submarine spring based on the lineament distribution and rose diagram analysis. Salinity and radon concentration were measured within the 1~2 km from the coastal lines. Radon activity decreased gradually from onshore to offshore. Vertical profiles of salinity at some stations showed lateral transport of water mass characterized by low salinity. Vertical profiles of salinity in the Ilkwang Bay, which is a unique bay in the south-eastern coastal area of Busan Metropolitan City, also showed the occurrence of low salinity in the bottom seawater. Our results suggest the possible occurrence of submarine discharge of fresh groundwater in the coastal areas around Busan Metropolitan City. In the future, intensive research should be conducted for the exploration methods of submarine spring as well for the possible utility of submarine groundwater as alternative water resources.

Prediction of Concrete Corrosion using Electrodchemical Technique (전기화학적인 콘크리트 부식의 예측)

  • 이종권;박지환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.80-83
    • /
    • 2002
  • The effect of chloride content on the corrosion of reinforced bar in concrete was studied. The mixing ratio of the concrete was 1 : 1.78 : 5.35 : 4.73 (water : content : ballast : sand). The studied chloride content was in the range of 0∼3.5 wt%. The corrosion potentials were measured in every week for two years. The copper-copper sulfate electrode (CSE) was employed as a reference electrode. After two years, the corroded structure was examined and compared to measured corrosion potential. Any visible difference was founded in the specimen located indoor and outdoor. The chloride concentration enhanced rusting and reinforced bar, shifting the potential to active range. The results showed good argument with Van daveer criteria. In 3.5 wt% chloride, the potential shifted belong -350 mV after 58week. Specimen in 1.75 wt% chloride, showed the potential between -200 mV∼-350 mV. However those in free chloride solution maintained above -200 mV for the studied period. It can the concluded that the chloride enhanced corrosion of rebar in concrete and the electrochemical potential can be a promising corrosion monitoring technique.

  • PDF