• Title/Summary/Keyword: 열 형광선량계

Search Result 134, Processing Time 0.023 seconds

Characteristics of $CaSO_4$:Dy TL Dosimeters by Determining LLDs, Fadings and Sensitivity Changes in Repeat Uses (최소검출한계, 잠상퇴행 및 반복사용으로 인한 감도면화 결정에 의한 $CaSO_4$:Dy 열형광선량계 특성)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Hyung-Sub;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.161-170
    • /
    • 1997
  • Theoretical and experimental determination of the lower limits of detection (LLD) of C-300-A $CaSO_4$:Dy TL dosimeters which are currently used for the personnel monitoring in Korea Atomic Energy Research Institute(KAERI) are described with a critical level which is defined as the signal level above which a result has a probability of being due to a fluctuation of the background. The personnel monitoring processors can derived easily the LLD of their system using this method with the background readings of their service interval and the irradiation readings of the known doses. Experimental studies were also conducted for the fading rates of the dosimeters with the temperatures and humidities for 3 months. Finally sensitivity changes in repeat uses were measured for 40 times consecutive uses of the dosimeters. The applications of the experimental results of fading rates and sensitivity changes in real personnel monitoring services are discussed briefly.

  • PDF

Gamma-ray Dose Measurements in a Human Phantom Using Thermoluminescent Dosimeter

  • Yoo, Young-Soo;Lee, Hyun-Duk
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.239-247
    • /
    • 1974
  • A human phantom of polyethylene has been designed and sculptured for studying the effective radiation safety control. The phantom has the approximate size of the Korean adult and was sliced into thirty-five transverse slabs, 2.5 cm thick, The relative dose at the specified position was determined from the exposure that a TLD badge worn on the surface of the phantom body received from external ${\gamma}$-ray. The variation of the exposure as a function of depth in the phantom was measured for uncollimated ${\gamma}$-ray using TLD rods, and also isodose curves were obtained for the anatomical cross-section of the critical organs of the body. To simulate radiation exposure condition in the nuclear facility, measurements were made for given angles of incident ${\gamma}$-ray. The front to back attenuation factor for human phantom of thickness 20 cm was 0.439 for Cs$^{137}$ ${\gamma}$-ray which is in reasonable agreement with the published data.

  • PDF

A Comparison of Peripheral Doses Scattered from a Physical Wedge and an Enhanced Dynamic Wedge (금속쐐기와 기능강화동적쐐기의 조사야 주변부 선량 비교)

  • Park, Jong-Min;Kim, Hee-Jung;Min, Je-Soon;Lee, Je-Hee;Park, Charn-Il;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.107-117
    • /
    • 2007
  • In order to evaluate the radio-protective advantage of an enhanced dynamic wedge (EDW) over a physical wedge (PW), we measured peripheral doses scattered from both types of wedges using a 2D array of ion-chambers. A 2D array of ion-chambers was used for this purpose. In order to confirm the accuracy of the device we first compared measured profiles of open fields with the profiles calculated by our commissioned treatment planning system. Then, we measured peripheral doses for the wedge angles of $15^{\circ},\;30^{\circ},\;45^{\circ},\;and\;60^{\circ}$ at source to surface distances (SSD) of 80 cm and 90 cm. The measured points were located at 0.5 cm depth from 1 cm to 5 cm outside of the field edge. In addition, the measurements were repeated by using thermoluminescence dosimeters (TLD). The peripheral doses of EDW were (1.4% to 11.9%) lower than those of PW (2.5% to 12.4%). At 15 MV energy, the average peripheral doses of both wedges were 2.9% higher than those at 6MV energy. At a small SSD (80 cm vs. 90 cm), peripheral dose differences were more recognizable. The average peripheral doses to the heel direction were 0.9% lower than those to the toe direction. The results from the TLD measurements confirmed these findings with similar tendency. Dynamic wedges can reduce unnecessary scattered doses to normal tissues outside of the field edge in many clinical situations. Such an advantage is more profound in the treatment of steeper wedge angles, and shorter SSD.

  • PDF

Influence of Total Laryngectomy on Spinal Cord Dose in Advanced Laryngeal Cancers (진행된 후두암 환자에서 후두전절제술에 의한 척수선량 변화)

  • Kim, Jae-Cheol;Kim, Sung-Hwan;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.167-173
    • /
    • 1996
  • Purpose : This analysis was to evaluate the radiation dose around a tracheostoma and spinal cord in the case of advanced laryngeal cancers in which a total laryngectomy was done before radiotherapy. Materials and Methods : The radiation dose around a tracheostoma and spinal cord was measured by thermoluminescence and film dosimetry in the phantom, Radiotherapy treatment planning was done in 12 cases of advanced laryngeal cancer and compared with the measured dose in the phantom. Results : Mean spinal cord doses in the phantom by thermoluminescence dosimetry were $86.4\%$ (with a tracheostoma), $80.1\%$ (without a tracheostoma), and the difference was $6.3\%$. Mean spinal cord doses in the phantom by film dosimetry were $84.7\%$ (with a tracheostoma), $79.0\%$ (without a tracheostoma). and the difference were $5.7\%$. Calculated spinal cord doses in the phantom were $84.0\%$ (with a tracheostoma), $78.0\%$ (without a tracheostoma), and the difference was $6.0\%$. Mean calculated spinal cord doses in 12 patients were $83.1\%$ (with a tracheostoma), $76.9\%$ (without a tracheostoma). and the difference was $6.2\%$. Measured dose of lateral and posterior wall of the tracheostoma by film was low (depth of maximum dose = 12 mm). Conclusion : In the treatment planning of the advanced laryngeal cancers, the radiation dose of the tracheostoma and spinal cord should be evaluated and be followed by an appropriate management such as a bouls or a brachytherapy boost if the dose around the tracheostoma is low.

  • PDF

Effectiveness of a Custom-made Multi Purpose Brachytherapy Phantom (자체 제작한 근접방사선치료용 다목적 팬텀의 유용성 평가)

  • Jang, In-Gi;Lee, Jin-Joung;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2006
  • Purpose: To measure the dose for dose optimization at the reference point (A, B) and the critical organ with multi Purpose brachytherapy phantom (MPBP). For this wort the MPBP was custom made, and designed to reconstruct the treatment applicator using multi function applicator (MFA) in the same way as the treatment of patient. Materials and Methods: Dose measurements were made at the reference points (A, B) and the bladder with thermoluminescence dosimeter (TLD) for four patients with tandem and ovoid of uterine cervix cancer using the phantom. In Phantom, Total 20 times of the measurements were made with 5 times a patient. Results: The results of TLD measurements in MPBP phantom showed the relative error ranging from -3.2% to 3.8% at A point, and -1.4% to 4% at B point and 1.3% to 7.15% at the bladder of reference point. Conclusion: The reproducibility of dose measurement under the same condition as the treatment could be achieved using the custom-made MFA in phantom and the dose at the reference point (A, B) and bladder could be analyzed accurately. The measured dose acquired in MPBP can apply for the dose optimization.

  • PDF

Design of a TL Personal Dosimeter Identifiable PA Exposure and Development of Its Dose Evaluation Algorithm (후방피폭선량계측이 가능한 TL 개인선량계의 설계 및 선량평가 알고리즘 개발)

  • Kwon, J.W.;Kim, H.K.;Yang, J.S.;Kim, J.L.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.179-186
    • /
    • 2004
  • A single-dosimeter worn on the anterior surface of body of a worker was found to provide significant underestimation of dose to the worker when radiation comes from behind of the human body. Recently, several researchers suggested that this kind of underestimation can be corrected to a certain extent by using an extra dosimeter on the back. But this multiple dosimetry also has the disadvantages like overestimation lowering work efficiency or cost burden. In this study, a single dosimeter introducing asymmetric filters enabled to identify PA exposure was designed by monte-carlo simulation and experiments and its dose evaluation algorithm for AP-PA mixed radiation field was established. This algorithm was applicable to penetrating radiation which had the effective energy more than 100 keV. Besides, the dosimeter and algorithm in this study were possible to be applied to near PA exposure.

A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current (유리선량계의 단계별 관전류량 변화에 따른 특성연구)

  • Son, Jin-Hyun;Kim, Seong-Ho;Mun, Hyun-Jun;Kim, Lyun-Kyun;Son, In-Hwa;Kim, Young-Jun;Min, Jung-Whan;Kim, Ki-Won
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • This study was evaluated the linearity and reproducibility according to dose, and reproducibility according to delay time by changing tube current amount (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively, which are low energy radiations) using Glass Dosimeter (GD) and piranha semiconductor dosimeter which are used for measuring exposure dose. Measurements of radiation dose were performed using external detector of piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Conditions of measurement were 80 kVp, SSD 100 cm and exposure region is $10cm{\times}10cm$. Glass dosimeter was exposed to radiation. Twenty-four glass dosimeters were divided into six groups (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively), then measured. This study was resulted by measuring the linearity and reproducibility according to change of tube current in low energy field. In dose characteristic of GD, this study could be useful as previous study with regard to dose characteristic according to change of tube voltage in low energy field.

A study on Synthesis and Radiation Detector Fabrication of Thin Films by MW Plasma CVD (MWPECVD에 의한 박막의 합성과 방사선 검출 특성에 관한 연구)

  • Koo, Hyo-Geun;Lee, Duck-Kyu;Song, Jae-Heung;Noh, Kyung-Suk;Park, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.45-50
    • /
    • 2004
  • Synthesis diamond films have been deposited on the molybdenum substrates using an microwave plasma enhanced chemical vapor deposition method. The effects of deposition time, surface morphology, infrared transmittance and Raman scattering have been studied. Diamond deposited on molybdenum substrate for 100 hours by MW plasma CVD from $CH_4-H_2-O_2$ gas mixture had good crystallity with $100[{\mu}m]$ thickness needed for radiation detector. Diamond radiation detector of M-I-M type was made and the current of radiation detector was increased by increasing X-ray dose.

  • PDF

Anneal Characteristics of LiF:Mg,Cu,Na,Si Teflon TLDs (LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성)

  • Nam, Young-Mi;Chung, Woon-Hyuk;Lee, Dae-Won;Kim, Hyun-Ja;Kim, Gi-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.135-141
    • /
    • 1997
  • The study of anneal characteristics is important for TL dosimeter to reuse. To obtain the annealing condition of the recently developed, new TL dosimeter, LiF:Mg,Cu,Na,Si Teflon Tills in a disk type (diameter 4.5 mm, thickness about $90mg/cm^2$), we studied for pre-irradiation annealing, readout procedure and post-readout annealing, in order. The gamma irradiations were carried out with a $^{60}Co$, dose of 0.1 Gy. We have used the method that observe the variation of thermoluminescent(TL) intensity of these Teflon TLDs over repeated cycles by changing both anneal temperature and anneal time with the TLD reader and the oven. There is a 5% loss in sensitivity over the ten repeated readouts by the annealing condition:pre-irradiation annealing at $80^{\circ}C$ for one hour, readout to $280^{\circ}C$ and post-readout annealing at $270^{\circ}C$ for 20 seconds.

  • PDF

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.